BS EN 12390-5-2000 Testing hardened concrete. Flexural strength of test specimens.pdf

上传人:来看看 文档编号:3643953 上传时间:2019-09-19 格式:PDF 页数:12 大小:159.19KB
返回 下载 相关 举报
BS EN 12390-5-2000 Testing hardened concrete. Flexural strength of test specimens.pdf_第1页
第1页 / 共12页
BS EN 12390-5-2000 Testing hardened concrete. Flexural strength of test specimens.pdf_第2页
第2页 / 共12页
BS EN 12390-5-2000 Testing hardened concrete. Flexural strength of test specimens.pdf_第3页
第3页 / 共12页
BS EN 12390-5-2000 Testing hardened concrete. Flexural strength of test specimens.pdf_第4页
第4页 / 共12页
BS EN 12390-5-2000 Testing hardened concrete. Flexural strength of test specimens.pdf_第5页
第5页 / 共12页
亲,该文档总共12页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《BS EN 12390-5-2000 Testing hardened concrete. Flexural strength of test specimens.pdf》由会员分享,可在线阅读,更多相关《BS EN 12390-5-2000 Testing hardened concrete. Flexural strength of test specimens.pdf(12页珍藏版)》请在三一文库上搜索。

1、BRITISH STANDARD BS EN 12390-5:2000 Incorporating Corrigendum No. 1 Testing hardened concrete Part 5: Flexural strength of test specimens The European Standard EN 12390-5:2000 has the status of a British Standard ICS 91.100.30 ? Licensed copy:PONTYPRIDD COLLEGE, 05/06/2007, Uncontrolled Copy, BSI BS

2、 EN 12390-5:2000 This British Standard, having been prepared under the direction of the Sector Committee for Building and Civil Engineering, was published under the authority of the Standards Committee and comes into effect on 15 December 2000 BSI 2 November 2004 ISBN 0 580 36605 7 National foreword

3、 This British Standard is the official English language version of EN 12390-5:2000, including Corrigendum September 2004. It will supersede BS 1881-118:1983, which will be withdrawn in 2003 when the full package of concrete standards is available. The UK participation in its preparation was entruste

4、d by Technical Committee B/517, Concrete, to Subcommittee B/517/1, Concrete production and testing, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement internatio

5、nal or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “ International Standards Correspondence Index” , or by using the “ Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purpor

6、t to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee

7、any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 8, an

8、inside back cover and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. DateComments 15438 Corrigendum No. 1 2 November 2004Correction to Subclause 6.2 Licensed copy:PONTYPRIDD COLLEGE, 05/06/20

9、07, Uncontrolled Copy, BSI EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 12390-5 October 2000 ICS 91.100.30 Incorporating corrigendum September 2004 English version Testing hardened concrete - Part 5: Flexural strength of test specimens Essai pour bton durci - Partie 5: Rsistance la flexion s

10、ur prouvettes Prfung von Festbeton - Teil 5: Biegezugfestigkeit von Probekrpern This European Standard was approved by CEN on 18 February 2000. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a n

11、ational standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in a

12、ny other language made by translation under the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, German

13、y, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: rue de Stassart, 36 B-1050 Brussels 2000 CEN All right

14、s of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 12390-5:2000 E Licensed copy:PONTYPRIDD COLLEGE, 05/06/2007, Uncontrolled Copy, BSI Page 2 EN 12390-5:2000 B SI 0002-21 Contents Page Foreword.3 1 Scope3 2 Normative references4 3 Principle4 4 App

15、aratus.4 5 Test specimens4 6 Procedures.5 7 Expression of results6 8 Test report6 9 Precision.7 Annex A (normative) Loading by a centre-point load8 Figure 1 Arrangement of loading of test specimen (two-point loading)7 Figure 2 Arrangement of loading of test specimen (centre-point loading).7 Licensed

16、 copy:PONTYPRIDD COLLEGE, 05/06/2007, Uncontrolled Copy, BSI ? Page 3 EN 12390-5:2000 B SI 0002-21 Foreword This European Standard has been prepared by Technical Committee CEN/TC 104, Concrete (performance, production, placing and compliance criteria), the Secretariat of which is held by DIN. This E

17、uropean Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by April 2001, and conflicting national standards shall be withdrawn at the latest by December 2003. According to the CEN/CENELEC Internal Regulations, the n

18、ational standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and the United Kingdom

19、. This standard is one of a series concerned with testing concrete. It is based on the International Standard ISO 4013 - Concrete - Determination of flexural strength of test specimens. It is recognized good practice to include measurement of density prior to the determination of flexural strength,

20、as a check on compaction of the concrete. The two-point method of loading has been taken as the reference method, but the use of centre-point loading has been included as a normative annex. An inter-comparison of the two-point and the centre-point methods has been made as part of a test programme, p

21、art-funded by the EC under the Measurement and Testing Programme, contract MAT I-CT-94-CO43. The centre-point method gave results which were consistently 13 % higher than those from the two-point method. A draft for this standard was published in 1996 for CEN enquiry as prEN 12359. It was one of a s

22、eries of individually numbered test methods for fresh or hardened concrete. For convenience it has now been decided to combine these separate draft standards into three new standards with separate parts for each method, as follows: - Testing fresh concrete (EN 12350) - Testing hardened concrete (EN

23、12390) - Testing concrete in structures (EN 12504) The series prEN 12390 includes the following parts where the brackets give the numbers under which particular test methods were published for CEN enquiry: EN 12390 - Testing hardened concrete - Part 1: Shape, dimensions and other requirements of spe

24、cimens and moulds (former prEN 12356:1996) Part 2: Making and curing specimens for strength tests (former prEN 12379:1996) Part 3: Compressive strength of test specimens (former prEN 12394:1996) Part 4: Compressive strength - Specification for testing machines (former prEN 12390:1996) Part 5: Flexur

25、al strength of test specimens (former prEN 12359:1996) Part 6: Tensile splitting strength of test specimens (former prEN 12362:1996) Part 7: Density of hardened concrete (former prEN 12363:1996) Part 8: Depth of penetration of water under pressure (former prEN 12364:1996) 1 Scope This standard speci

26、fies a method for the determination of the flexural strength of specimens of hardened concrete. Licensed copy:PONTYPRIDD COLLEGE, 05/06/2007, Uncontrolled Copy, BSI ? Page 4 EN 12390-5:2000 B SI 0002-21 2 Normative references This European Standard incorporates by dated or undated reference, provisi

27、ons from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by

28、amendment or revision. For undated references the latest edition of the publication referred to applies (including amendments). EN 12350-1, Testing fresh concrete Part 1: Sampling. EN 12390-1:2000, Testing hardened concrete Part 1: Shape, dimensions and other requirements of specimens and moulds. EN

29、 12390-2, Testing hardened concrete Part 2: Making and curing specimens for strength tests. EN 12390-4, Testing hardened concrete Part 4: Compressive strength Specification for testing machines. 3 Principle Prismatic specimens are subject to a bending moment by the application of load through upper

30、and lower rollers. The maximum load sustained is recorded and the flexural strength is calculated. 4 Apparatus 4.1 Testing machine The test shall be carried out using a testing machine conforming to prEN 12390-4. 4.2 Force application The device for applying loads (see Figure 1) shall consist of: tw

31、o supporting rollers; two upper rollers carried by an articulated cross member, which divides the load applied by the machine equally between the two rollers. All rollers shall be manufactured from steel and shall have a circular cross-section with a diameter of 20 mm to 40 mm. They shall be at leas

32、t 10 mm longer than the width of the test specimen. Three rollers, including the two upper ones, shall be capable of rotating freely around their axis and of being inclined in a plane normal to the longitudinal axis of the test specimen. The distance, l, between the outer rollers (i.e. the span) sha

33、ll be equal to 3d, where d is the width of the specimen. The distance between the inner rollers shall be equal to d. The inner rollers shall be equally spaced between the outer rollers as shown in Figure 1. All rollers shall be adjusted to the positions illustrated in Figure 1 to an accuracy of 2,0

34、mm. 5 Test specimens 5.1 General The test specimens shall be prisms conforming to EN 12390-1. Specimens cast in moulds shall conform to EN 12350-1 and EN 12390-2. The direction of casting shall be identified on the specimen. Sawn specimens which meet the requirements of EN 12390-1 may also be tested

35、. The specimens shall be examined and any abnormalities observed shall be reported. Licensed copy:PONTYPRIDD COLLEGE, 05/06/2007, Uncontrolled Copy, BSI ? Page 5 EN 12390-5:2000 B SI 0002-21 5.2 Adjustment of test specimens Where the dimensions or shapes of test specimens do not conform to 4.3 of EN

36、 12390-1 because they exceed the respective tolerances, they shall be rejected or adjusted as follows: uneven surfaces shall be levelled by grinding; the deviation of angles shall be corrected by cutting and/or grinding. 6 Procedures 6.1 Preparation and positioning of specimens For specimens stored

37、in water, wipe excess moisture from the surface of the specimen before placing in the testing machine. Wipe clean all testing machine bearing surfaces and remove any loose grit or other extraneous material from the surfaces of the specimen that will be in contact with the rollers. Place the test spe

38、cimen in the machine, correctly centred and with the longitudinal axis of the specimen at right angles to the longitudinal axis of the upper and lower rollers. Ensure that the reference direction of loading is perpendicular to the direction of casting of the specimen. NOTE The test result may be aff

39、ected by the direction of loading with respect to the direction of casting. 6.2 Loading Do not apply the load until all loading and supporting rollers are resting evenly against the test specimen. Select a constant rate of stress within the range 0,04 MPa/s (N/mm.s) to 0,06 MPa/s (N/mm.s). Apply the

40、 load without shock and increase continuously, at the selected constant rate 10 %, until no greater load can be sustained. NOTE The required loading rate on the testing machine is given by the formula: l dd s =R 2 2 1? ? where: R is the required loading rate, in newtons per second; s is the stress r

41、ate, in megapascals per second (newtons per square millimetre per second); d1 and d2 are the lateral dimensions of the specimen, in millimetres; l is the spacing of the lower rollers, in millimetres. When using manually controlled testing machines, correct, by appropriate adjustment of the controls,

42、 any tendency for the selected rate of loading to decrease, as specimen failure is approached. Record the maximum load indicated. Report a fracture outside the loading rollers. (see Figure 1). Licensed copy:PONTYPRIDD COLLEGE, 05/06/2007, Uncontrolled Copy, BSI ? Page 6 EN 12390-5:2000 B SI 0002-21

43、7 Expression of rules The flexural strength is given by the equation: where fcf is the flexural strength, in megapascals (newtons per square millimetre); F is the maximum load, in newtons; l is the distance between the supporting rollers, in millimetres; d1 and d2 are the lateral dimensions of the s

44、pecimen, in millimetres (see Figure 1). Express the flexural strength to the nearest 0,1 MPa (N/mm) 8 Test report The report shall include: a) identification of the test specimen; b) designated or measured dimensions of the specimen; c) details of adjustment by grinding (if appropriate); d) type of

45、apparatus: two point/centre point; e) surface moisture condition of specimen at time of test (saturated/moist); f) date of test; g) maximum load at fracture, in kilonewtons; h) flexural strength of specimen to nearest 0,1 MPa (N/mm2); i) location of fracture (if outside upper rollers); j) appearance

46、 of the concrete (if unusual); k) any deviation from the standard test method; l) a declaration from the person technically responsible for the test that the testing was carried out in accordance with this standard, except as detailed in item k). The report may include: m) condition of specimen at r

47、eceipt for storage; n) age of specimen at time of test (if known); o) appearance of the concrete (if unusual). dd lF = f 2 2 1 cf ? ? Licensed copy:PONTYPRIDD COLLEGE, 05/06/2007, Uncontrolled Copy, BSI ? Page 7 EN 12390-5:2000 B SI 0002-21 9 Precision There is currently no precision data for this t

48、est, or the alternative test set out in Annex A. Key 1 Loading roller (capable of rotation and of being inclined) 2 Supporting roller 3 Supporting roller (capable of rotation and of being inclined) Figure 1 Arrangement of loading of test specimen (two-point loading) Key 1 Loading roller (capable of

49、rotation and of being inclined) 2 Supporting roller 3 Supporting roller (capable of rotation and of being inclined) Figure 2 Arrangement of loading of test specimen (centre-point loading) Licensed copy:PONTYPRIDD COLLEGE, 05/06/2007, Uncontrolled Copy, BSI ? Page 8 EN 12390-5:2000 B SI 0002-21 Annex A (normative) Loading by a centre-point load A.1 In t

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 其他


经营许可证编号:宁ICP备18001539号-1