资源描述

《BS EN 1253-1-1999 Gullies for buildings. Requirements.pdf》由会员分享,可在线阅读,更多相关《BS EN 1253-1-1999 Gullies for buildings. Requirements.pdf(12页珍藏版)》请在三一文库上搜索。

1、| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | BRITISH STANDARD BS EN 1253-1:1999 The Eur

2、opean Standard EN 1253-1:1999 has the status of a British Standard ICS 91.140.80 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW Gullies for buildings Part 1: Requirements Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 10:05:48 GMT+00:00 2006, Uncontrolled Copy, (c) BS

3、I This British Standard, having been prepared under the direction of the Sector Committee for Building and Civil Engineering, was published under the authority of the Standards Committee and comes into effect on 15 September 1999 BSI 09-1999 ISBN 0 580 32763 9 BS EN 1253-1:1999 Amendments issued sin

4、ce publication Amd. No.DateComments National foreword ThisBritishStandardistheEnglishlanguageversionofEN1253-1:1999. The UK participation in its preparation was entrusted by Technical Committee B/505, Wastewater engineering, to Subcommittee B/505/11, Waste fittings for sanitary appliances, which has

5、 the responsibility to: aid enquirers to understand the text; present to the responsible European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. A list

6、of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled International

7、Standards Correspondence Index, or by using the Find facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Stan

8、dard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 9 and a back cover. The BSI copyright notice displayed in this document indicates when this document was last issued. Licensed

9、Copy: sheffieldun sheffieldun, na, Sat Oct 28 10:05:48 GMT+00:00 2006, Uncontrolled Copy, (c) BSI CEN European Committee for Standardization Comite Europe en de Normalisation Europa isches Komitee fu r Normung Central Secretariat: rue de Stassart 36, B-1050 Brussels 1999 CEN All rights of exploitati

10、on in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1253-1:1999 E EUROPEAN STANDARDEN 1253-1 NORME EUROPE ENNE EUROPA ISCHE NORM April 1999 ICS 91.140.80 English version Gullies for buildings Part 1: Requirements Avaloirs et siphons pour ba timents Partie 1: Spe

11、cifications Abla ufe fu r Geba ude Teil 1: Anforderungen This European Standard was approved by CEN on 3 May 1998. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any

12、alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by t

13、ranslation under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Irela

14、nd, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 10:05:48 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 2 EN 1253-1:1999 BSI 09-1999 Foreword This European Standard has been prepared by Techn

15、ical Committee CEN/TC 165, Waste water engineering, the Secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text, or by endorsement, at the latest by October 1999, and conflicting national standards shall

16、 be withdrawn at the latest by October 1999. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland

17、, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and the United Kingdom Contents Page Foreword2 1Scope3 2Normative references3 3Definitions3 4Loading strength5 5Places of installation5 5.1General5 5.2Exceptions6 6Nominal sizes6 7Materials6 8Design and construction6 8.1G

18、eneral6 8.2Appearance6 8.3Depth of water seal6 8.4Resistance of water seal to pressure6 8.5Apertures in gratings6 8.6Blockage prevention: trapped gullies7 8.6.1 Access for cleaning7 8.6.2 Self-cleansing capacity7 8.6.3 Anti-blockage7 8.7Side inlets7 8.8Thermal behaviour7 8.8.1 Temperature cycling fo

19、r floor gullies7 8.8.2 Additional mounting conditions and test conditions for gullies for use with sheet floor covering7 8.8.3 Roof outlets7 8.8.4 Behaviour when exposed to hot bitumen or asphalt7 8.9Tightness7 8.9.1 Odourtightness: trapped gullies7 8.9.2 Watertightness for gully bodies7 8.9.3 Gulli

20、es for use with a membrane7 8.9.4 Gullies for use with a sheet floor covering8 8.9.5 Gullies with factory affixed skirt membrane8 8.9.6 Watertightness for extensions8 8.10Mechanical strength8 8.10.1 Extensions for gullies for use with sheet floor covering8 8.10.2 Membrane clamping ring8 8.10.3 Gulli

21、es with factory affixed skirt membrane8 8.11Flow rates8 8.11.1 Water through the grating8 8.11.2 Water through the grating and side inlets8 8.11.3 Water through the side inlet8 8.12Roof outlets for siphonic drainage systems8 8.12.1 Fitness for the purpose8 8.12.2 Coefficient of hydraulic loss8 9Mark

22、ing8 10Quality control8 Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 10:05:48 GMT+00:00 2006, Uncontrolled Copy, (c) BSI ? Page 3 EN 1253-1:1999 BSI 09-1999 1 Scope This European Standard classifies gullies, gives guidance for places of installation and specifies requirements for the const

23、ruction, design, performance and marking of factory made gullies for buildings, irrespective of material, for use in drainage systems operating under gravity including siphonic systems. NOTEAlthough normally used to convey domestic waste water, industrial waste water and rainwater, gullies can conve

24、y other waste water provided there is no risk of damage to components or of injury to health. This European Standard does not apply to gully tops and manhole tops which are specified in EN 124. 2 Normative references This European Standard incorporates by dated or undated reference, provisions from

25、other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment

26、 or revision. For undated references the latest edition of the publication referred to applies. EN 124:1994, Gully tops and manhole tops for vehicular and pedestrian areas Design requirements, testing, marking, quality control. EN 476, General requirements for components used in discharge pipes, dra

27、ins and sewers for gravity systems. EN 1253-2:1998, Gullies for buildings Part 2: Test methods. EN 1253-3, Gullies for buildings Part 3: Quality control. 3 Definitions For the purpose of this standard, the following definitions apply. 3.1 gully discharge fitting the top of which is a grating or cove

28、r capable of installation at ground, floor or roof level, intended to receive waste water either through apertures in a grating and/or from pipes connected to the body of the gully (see Figure 1) NOTEA gully can include an integral trap and a sediment bucket (see Figure 2). 3.2 side inlet gully gull

29、y with one or more integral inlets for underfloor or underground connections (see Figure 2) 3.3 roof outlet a non-trapped gully, used in a roof (see Figure 3) NOTEA roof outlet can include an anti-vortex device. 2Membrane clamping ring 4Grating/cover and frame 5Spigot 6Body 8Membrane 10 Extension 12

30、 Sheet floor covering Figure 1 Gully, non-trapped (typical example) 1Finished floor 3Sediment bucket 4Grating/cover and frame 5Spigot 6Body 7Side inlet 8Membrane 9Access for cleaning 11 Connecting flange 14 Depth of water seal Figure 2 Side inlet gully, trapped (typical example) Licensed Copy: sheff

31、ieldun sheffieldun, na, Sat Oct 28 10:05:48 GMT+00:00 2006, Uncontrolled Copy, (c) BSI ? Page 4 EN 1253-1:1999 BSI 09-1999 4Grating/cover and frame 6Body 8Membrane 11 Connecting flange 13 Roof layer Figure 3 Roof outlet (typical example) 3.4 grating removable component with apertures which permit th

32、e discharge of waste water 3.5 frame support for a grating or cover which is connected to a body either directly or by means of a membrane clamping collar or an extension 3.6 cover removable part of an access cover which covers the opening 3.7 body part of a gully below or in the floor, ground or ro

33、of on which the grating/frame/extension is mounted, and to which pipework is connected 3.8 extension component used to adjust the height of a grating or cover above a body 3.9 membrane clamping ring component used to clamp a membrane or a sheet floor covering to a body or extension 3.10 joint connec

34、tion between the adjacent ends of two components including the means of sealing 3.11 connecting flange separate or an integral part of a body or of an extension which receives a membrane or sheet floor covering 3.12 nominal size (DN) numerical indication of size which is a convenient integer approxi

35、mately equal to the internal diameter (DN/ID) or the external diameter (DN/OD) in millimetres 3.13 external diameter mean external diameter of the pipe barrel at any cross section 3.14 internal diameter mean internal diameter of the pipe barrel at any cross section Licensed Copy: sheffieldun sheffie

36、ldun, na, Sat Oct 28 10:05:48 GMT+00:00 2006, Uncontrolled Copy, (c) BSI ? Page 5 EN 1253-1:1999 BSI 09-1999 3.15 gravity drainage system system where flow is caused by gravity and where the pipe normally operates partially full 3.16 trap removable or integral part of the body which prevents by mean

37、s of water seal the passage of foul air from the outlet to the inlet 3.17 depth of water seal effective height of water in the trap (h) which prevents the passage of foul air (see Figure 4) a) Inlet b) Outlet (examples) c) Water level Figure 4 Depth of water seal 3.18 domestic waste water non-faecal

38、 waste water discharged from appliances in kitchens, laundry rooms, lavatories, bathrooms, toilets, and similar facilities 3.19 industrial waste water waste water resulting wholly or partially from any industrial or commercial activity 3.20 sheet floor covering flexible watertight finished layer for

39、 floors affixed to the flange by bonding and/or by means of a clamping ring 3.21 membrane watertight and/or damp proof layer attached to the gully either in the floor or on the floor or roof 3.22 head of water distance a as shown in Figure 5 Figure 5 Head of water 3.23 siphonic drainage system syste

40、m for drainage of rainwater in which the outlets and pipework enable the system to flow completely full under design conditions and make use of the total height available between the outlets and the point of change to partially filled flow 4 Loading strength Gullies are classified by loading strengt

41、h, when tested in accordance with EN 1253-2:1998, clause 4, into the following classes: H 1,5, K 3, L 15, M 125. Gullies not accessible to either vehicular or foot traffic or not required to withstand external loads are not classified. 5 Places of installation 5.1 General A guide for selecting the c

42、lass of gully appropriate to the place of installation is given below. The selection of the appropriate class is the responsibility of the specifier. Class H 1,5 Unused flat roofs such as felt-and-gravel roofs, gravel fill roofs and similar. Class K 3 Areas without vehicular traffic, such as bathroo

43、ms in dwellings, old peoples homes, hotels, schools, swimming baths, public wash and shower facilities, balconies, loggias, terraces and roofs with greenery. Non-load bearing gullies in bathrooms shall fulfil the requirements of class H 1,5. Class L 15 Areas with light vehicular traffic, excluding f

44、ork-lift trucks, in commercially used premises. Class M 125 Areas with vehicular traffic, such as car parks, factories and workshops. Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 10:05:48 GMT+00:00 2006, Uncontrolled Copy, (c) BSI ? Page 6 EN 1253-1:1999 BSI 09-1999 Table 1 Apertures in gr

45、atings ClassDimensions of apertures in gratings Minimum mm Maximum mm H 1,5*)615 K 3610 (max. 8 mm in barefoot areas) L 15615 (max. 8 mm in barefoot areas) M 125625 *)Where a gravel guard is incorporated the maximum can be up to 25 mm. Class C 250 to F 900 gullies and tops conforming to EN 124 shall

46、 be used for all areas subject to special stresses, such as exhibition halls, market halls, factory sheds and aircraft hangars. 5.2 Exceptions Non-load bearing gratings for places of installation which are not accessible to vehicles and pedestrians (protected by suitable masonry surroundings) and wh

47、ich are not covered by the places of installation listed above nor by EN 124 shall at least conform to the test requirements given in EN 1253-2:1998, clause 4. 6 Nominal sizes Recommended nominal sizes are defined by internal diameter of outlet (DN/ID) and by external diameter of outlet (DN/OD) as f

48、ollows. Nominal sizes DN/ID:30; 40; 50; 70; 75; 100; 125; 150; 200 Nominal sizes DN/OD:32; 40; 50; 63; 75; 90; 100; 110; 125; 160; 200 NOTEOther nominal sizes which are at present in use are permissible, but they may be reconsidered in the future. 7 Materials Materials shall withstand domestic waste

49、 water up to a temperature of 95 8C and industrial waste water as specified by the specifier. Materials for roof outlets shall be resistant to rainwater and, when needed, to hot bitumen. Materials shall withstand the stresses likely to occur during installation and operation. Gullies made of materials which are not inherently corrosion-resistant shall be protected by corrosion prevention. 8 Design and construction 8.1 General Gullies shall be capable of being connected to pipework syst