NFPA 485-1999 Standard for the Storage Handling Processing and Use of Lithium Metal.pdf

上传人:小小飞 文档编号:3674511 上传时间:2019-09-20 格式:PDF 页数:16 大小:138.11KB
返回 下载 相关 举报
NFPA 485-1999 Standard for the Storage Handling Processing and Use of Lithium Metal.pdf_第1页
第1页 / 共16页
NFPA 485-1999 Standard for the Storage Handling Processing and Use of Lithium Metal.pdf_第2页
第2页 / 共16页
NFPA 485-1999 Standard for the Storage Handling Processing and Use of Lithium Metal.pdf_第3页
第3页 / 共16页
NFPA 485-1999 Standard for the Storage Handling Processing and Use of Lithium Metal.pdf_第4页
第4页 / 共16页
NFPA 485-1999 Standard for the Storage Handling Processing and Use of Lithium Metal.pdf_第5页
第5页 / 共16页
亲,该文档总共16页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《NFPA 485-1999 Standard for the Storage Handling Processing and Use of Lithium Metal.pdf》由会员分享,可在线阅读,更多相关《NFPA 485-1999 Standard for the Storage Handling Processing and Use of Lithium Metal.pdf(16页珍藏版)》请在三一文库上搜索。

1、NFPA 485 Standard for the Storage, Handling, Processing, and Use of Lithium Metal 1999 Edition National Fire Protection Association, 1 Batterymarch Park, PO Box 9101, Quincy, MA 02269-9101 An International Codes and Standards Organization Copyright National Fire Protection Association, Inc. One Batt

2、erymarch Park Quincy, Massachusetts 02269 IMPORTANT NOTICE ABOUT THIS DOCUMENT NFPA codes and standards, of which the document contained herein is one, are developed through a consensus stan- dards development process approved by the American National Standards Institute. This process brings togethe

3、r volunteers representing varied viewpoints and interests to achieve consensus on fire and other safety issues. While the NFPA admin- isters the process and establishes rules to promote fairness in the development of consensus, it does not independently test, evaluate, or verify the accuracy of any

4、information or the soundness of any judgments contained in its codes and standards. The NFPA disclaims liability for any personal injury, property or other damages of any nature whatsoever, whether special, indirect, consequential or compensatory, directly or indirectly resulting from the publicatio

5、n, use of, or reliance on this document. The NFPA also makes no guaranty or warranty as to the accuracy or completeness of any information pub- lished herein. In issuing and making this document available, the NFPA is not undertaking to render professional or other services for or on behalf of any p

6、erson or entity. Nor is the NFPA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care

7、in any given circumstances. The NFPA has no power, nor does it undertake, to police or enforce compliance with the contents of this document. Nor does the NFPA list, certify, test or inspect products, designs, or installations for compliance with this document. Any certification or other statement o

8、f compliance with the requirements of this document shall not be attributable to the NFPA and is solely the responsibility of the certifier or maker of the statement. NOTICES All questions or other communications relating to this document and all requests for information on NFPA procedures governing

9、 its codes and standards development process, including information on the procedures for requesting Formal Interpretations, for proposing Tentative Interim Amendments, and for proposing revisions to NFPA documents during regular revision cycles, should be sent to NFPA headquarters, addressed to the

10、 attention of the Secretary, Standards Coun- cil, National Fire Protection Association, 1 Batterymarch Park, P.O. Box 9101, Quincy, MA 02269-9101. Users of this document should be aware that this document may be amended from time to time through the issuance of Tentative Interim Amendments, and that

11、 an official NFPA document at any point in time consists of the current edition of the document together with any Tentative Interim Amendments then in effect. In order to determine whether this document is the current edition and whether it has been amended through the issuance of Tentative Interim

12、Amendments, consult ap- propriate NFPA publications such as the National Fire Codes Subscription Service, visit the NFPA website at www.nfpa.org, or contact the NFPA at the address listed above. A statement, written or oral, that is not processed in accordance with Section 16 of the Regulations Gove

13、rning Com- mittee Projects shall not be considered the official position of NFPA or any of its Committees and shall not be considered to be, nor be relied upon as, a Formal Interpretation. The NFPA does not take any position with respect to the validity of any patent rights asserted in connection wi

14、th any items which are mentioned in or are the subject of this document, and the NFPA disclaims liability of the infringement of any patent resulting from the use of or reliance on this document. Users of this document are expressly advised that deter- mination of the validity of any such patent rig

15、hts, and the risk of infringement of such rights, is entirely their own responsi- bility. Users of this document should consult applicable federal, state, and local laws and regulations. NFPA does not, by the publication of this document, intend to urge action that is not in compliance with applicab

16、le laws, and this document may not be construed as doing so. ? Licensing Policy This document is copyrighted by the National Fire Protection Association (NFPA). By making this document avail- able for use and adoption by public authorities and others, the NFPA does not waive any rights in copyright

17、to this docu- ment. 1. Adoption by Reference Public authorities and others are urged to reference this document in laws, ordinances, regulations, administrative orders, or similar instruments. Any deletions, additions, and changes desired by the adopting authority must be noted separately. Those usi

18、ng this method are requested to notify the NFPA (Attention: Secretary, Stan- dards Council) in writing of such use. The term “ adoption by reference” means the citing of title and publishing information only. 2. Adoption by Transcription A. Public authorities with lawmaking or rule-making powers onl

19、y, upon written no- tice to the NFPA (Attention: Secretary, Standards Council), will be granted a royalty-free license to print and republish this document in whole or in part, with changes and additions, if any, noted separately, in laws, ordinances, regulations, admin- istrative orders, or similar

20、 instruments having the force of law, provided that: (1) due notice of NFPA s copyright is con- tained in each law and in each copy thereof; and (2) that such printing and republication is limited to numbers sufficient to satisfy the jurisdiction s lawmaking or rule-making process. B. Once this NFPA

21、 Code or Standard has been adopted into law, all printings of this document by public authorities with lawmaking or rule-making powers or any other persons desir- ing to reproduce this document or its contents as adopted by the jurisdiction in whole or in part, in any form, upon written request to N

22、FPA (Attention: Secretary, Standards Council), will be granted a nonexclusive license to print, republish, and vend this document in whole or in part, with changes and additions, if any, noted separately, provided that due notice of NFPA s copyright is contained in each copy. Such license shall be g

23、ranted only upon agreement to pay NFPA a royalty. This royalty is required to provide funds for the research and development necessary to continue the work of NFPA and its volunteers in continually updating and revising NFPA standards. Under certain circumstances, public authorities with law- making

24、 or rule-making powers may apply for and may receive a special royalty where the public interest will be served thereby. 3. Scope of License Grant The terms and conditions set forth above do not extend to the index of this document. (For further explanation, see the Policy Concerning the Adoption, P

25、rinting, and Publication of NFPA Documents, which is available upon request from the NFPA.) ? 4851 Copyright 1999 NFPA, All Rights Reserved NFPA 485 Standard for the Storage, Handling, Processing, and Use of Lithium Metal 1999 Edition This edition of NFPA 485, Standard for the Storage, Handling, Pro

26、cessing, and Use of Lithium Metal, was prepared by the Technical Committee on Combustible Metals and Metal Dusts and acted on by the National Fire Protection Association, Inc., at its May Meeting held May 1720, 1999, in Baltimore, MD. It was issued by the Standards Council on July 22, 1999, with an

27、effec- tive date of August 13, 1999, and supersedes all previous editions. Changes other than editorial are indicated by a vertical rule in the margin of the pages on which they appear. These lines are included as an aid to the user in identifying changes from the previous edition. This edition of N

28、FPA 485 was approved as an American National Standard on August 13, 1999. Origin and Development of NFPA 485 The Committee on Combustible Metals and Metal Dusts began its work on developing a proposed standard on lithium at a Committee meeting in December 1990. The Committee reviewed drafts of the p

29、roposed standard and continued to revise the draft standard at Com- mittee meetings held in June 1991, October 1991, March 1992, November 1992, March 1993, and November 1993. The standard was submitted and adopted at the 1994 Annual Meeting in San Francisco, CA, May 1618, 1994. The 1994 edition was

30、the first edition of this standard. The 1999 edition has relatively few major changes from the 1994 edition. Numerous minor changes throughout the text of the standard and appendixes further clarify requirements. The scope of the document, as well as several definitions and require- ments, have been

31、 rewritten to make it easier to comply with and enforce the standard. ? 4852STORAGE, HANDLING, PROCESSING, AND USE OF LITHIUM METAL 1999 Edition Technical Committee on Combustible Metals nor does it approve or evalu- ate testing laboratories. In determining the acceptability of installations, proced

32、ures, equipment, or materials, the author- ity having jurisdiction may base acceptance on compliance with NFPA or other appropriate standards. In the absence of such standards, said authority may require evidence of proper installation, procedure, or use. The authority having jurisdic- tion may also

33、 refer to the listings or labeling practices of an organization that is concerned with product evaluations and is thus in a position to determine compliance with appropriate standards for the current production of listed items. A-1-5 Authority Having Jurisdiction. The phrase “authority having jurisd

34、iction” is used in NFPA documents in a broad manner, since jurisdictions and approval agencies vary, as do their responsibilities. Where public safety is primary, the authority having jurisdiction may be a federal, state, local, or other regional department or individual such as a fire chief; fire m

35、arshal; chief of a fire prevention bureau, labor depart- ment, or health department; building official; electrical inspector; or others having statutory authority. For insur- ance purposes, an insurance inspection department, rating bureau, or other insurance company representative may be the author

36、ity having jurisdiction. In many circumstances, the property owner or his or her designated agent assumes the role of the authority having jurisdiction; at government installations, the commanding officer or departmental offi- cial may be the authority having jurisdiction. A-1-5 Listed. The means fo

37、r identifying listed equipment may vary for each organization concerned with product evalu- ation; some organizations do not recognize equipment as listed unless it is also labeled. The authority having jurisdic- tion should utilize the system employed by the listing organi- zation to identify a lis

38、ted product. A-1-5 Noncombustible. Materials reported as noncombusti- ble, where tested in accordance with ASTM E 136, Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750C, are considered noncombustible materials. A-1-5 Pyrophoric Material. For further clarification of p

39、yro- phoric, refer to 49 CFR 173.124(b)(1). A-2-1 Lithium reacts with moisture from any available source, such as concrete, the atmosphere, and human skin. The degree and speed of the reaction varies with conditions; there- fore, the best approach is to take precautions to keep moisture away from li

40、thium. A-2-2 Small facilities isolated from other facilities under the same ownership are ideal for handling and processing lith- ium. In the event of an uncontrolled lithium emergency, property damage would be considerably less. A-2-3 Lithium fire residue products can include metallic lith- ium, li

41、thium nitride, lithium oxide, or lithium hydroxide, which can absorb moisture. A-2-3.1 Once a lithium fire is extinguished, lithium is usually still present in sufficient quantity to create adverse reactions and exhibit the burning characteristics of lithium. Lithium fire residues can include other

42、reactive components. These residues can react with each other and cause reignition. Con- tainers of residues can be purged with argon gas or the resi- dues can be coated with water-free mineral oil to reduce the potential for reaction. Under solid waste environmental regu- lations, these residues co

43、uld be considered a hazardous waste, and subject to hazardous waste packaging, storage, notifica- tion and disposal regulations. A-3-1.2 Consideration should be given to automatic fire detec- tion systems within these facilities to ensure life safety. A-3-1.4 The requirement for watertight roof deck

44、s is an effort to ensure that buildings are designed and maintained to min- imize possible leaks from weather conditions. Special care should be given to maintaining these roofs, especially in cli- mates where heavy amounts of snow are expected. A-3-1.6 Nonslip surfaces should be provided due to the

45、 poten- tial presence of mineral oil on the floor. Gratings should be used only where containment provisions have been provided below the area or where access can be restricted below the area. A-3-2.1 Laboratories, bathrooms, and other areas not dedi- cated to the processing of lithium can have wate

46、r leaks. Con- sideration needs to be given to preventing water from such ? APPENDIX A4859 1999 Edition leaks from entering the lithium processing areas, creating fire and explosion hazards. A-4-1.6 See NFPA 51B, Standard for Fire Prevention in Use of Cut- ting and Welding Processes. A-4-1.7 When eva

47、luating the amounts needed for process use, the risks and fire exposures should be evaluated with other processing requirements. Lithium in containers staged for melting should be consid- ered process vessels. A-4-2.2 Solid lithium is supplied in a variety of forms (e.g., ingots and ribbon), which a

48、re often individually protected in small cans or airtight foil pouches. If individual containers are not supplied and the containers are opened, lithium is exposed to surrounding air, causing slow reactions to take place. It is for this reason that once the container is opened, only that amount of l

49、ithium intended to be used should be removed. A-5-1.1 Lithium is shipped from lithium manufacturers in DOT- or HM 181-approved containers that should continue to act as storage containers. Containers should be sealed to remain airtight, with lithium coated with mineral oil or packed under an argon cover. Containers used to store lith- ium under mineral oil for long-term storage (over three months) should be inverted to redistribute the mineral oil cov- ering the lithium. Containers packed under an argon cover should be regular