1、BRITISH STANDARD BS 9526 N0003:1979 Specification for Multi-contact edge socket electrical connectors Single or double sided, open ended, guide key location, replaceable contacts, through-board solder or wire wrap terminations Full assessment level UDC 621.315.683 Licensed Copy: London South Bank Un

2、iversity, London South Bank University, Fri Dec 08 04:30:12 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9526 N0003:1979 BSI 10-1999 Committee reference ECL/21 ISBN 0 580 11061 3 Amendments issued since publication Amd. No.DateComments Licensed Copy: London South Bank University, London South Bank

3、University, Fri Dec 08 04:30:12 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9526 N0003:1979 BSI 10-1999i Contents Page 1Pattern number1 2Related documents1 3Description of component and intended application1 4Marking of the connector and package2 5Ordering information3 6Outline drawings3 7Ratings3

4、 8Characteristics4 9Certified test records (CTRs)5 10Additional information5 11Quality assessment procedure5 12Inspection requirements5 Appendix A Outline drawings13 Appendix B Table of preferred specimens in minimum quantities for group D tests22 Appendix C Method of test for termination torsion24

5、Appendix D Method of test for guide key retention25 Appendix E Method of test for static load (mating)26 Appendix F Method of test for moulding strength26 Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 04:30:12 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9526

6、 N0003:1979 ii BSI 10-1999 A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pag

7、es This document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 26 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Licensed Copy: Londo

8、n South Bank University, London South Bank University, Fri Dec 08 04:30:12 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9526 N0003:1979 BSI 10-19991 1 Pattern number The specification number without the letters BS is used as the pattern number. This range of connectors is known as pattern 9526 N000

9、3. 2 Related documents BS 6001, Sampling procedures and tables for inspection by attributes. BS 9000, General requirements for electronic components of assessed quality. BS 9520, Electrical connectors of assessed quality for frequencies below 3MH2: generic data and methods of test. BS 9526, Rules fo

10、r the preparation of detail specifications for electrical edge socket connectors of assessed quality. Full and basic assessment levels. PD 9002, BS 9000 Component selection guide. 3 Description of component and intended application Multi-contact edge socket connectors with 2.54 mm contact spacing an

11、d open ends. Intended for use with single or double-sided printed boards of 1.42 mm to 1.80 mm thickness. The connectors are available in sizes up to a maximum of 85 contacts per side with three different seated height styles. Front or rear removable/replaceable contacts are available in the connect

12、or range with front or rear release for each direction of removal. Replacement contacts and keys used with ranges of connectors shall be identical to the originals. The method of contact removal and replacement and the tools required will depend upon the design of individual connectors. The mandator

13、y method of location is by a guide key which replaces an opposite pair of contacts and one such key shall be provided per connector. (See clause 9.) The establishment of all safety factors concerning the use of these connectors is the responsibility of the user. ELECTRONIC COMPONENTS OF ASSESSED QUA

14、LITY DETAIL SPECIFICATION IN ACCORDANCE WITH BS 9520 MANUFACTURERS TYPE NUMBER see PD 9002. For ordering information see clause 5 Typical connector For marking information, see clause 4 For outline drawings, see A.1 and A.2. MULTI CONTACT EDGE SOCKET ELECTRICAL CONNECTOR SINGLE OR DOUBLE SIDED OPEN

15、ENDED, WITH GUIDE KEY LOCATION, REPLACEABLE CONTACTS, THROUGH-BOARD SOLDER OR WIRE WRAP TERMINATIONS ENVIRONMENTAL CATEGORY 55/124/21 FULL ASSESSMENT LEVEL Refer to Qualified Products List PD 9002 for details of manufacturers approved to this specification. Licensed Copy: London South Bank Universit

16、y, London South Bank University, Fri Dec 08 04:30:12 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9526 N0003:1979 2 BSI 10-1999 4 Marking of the connector and package The marking shall be in accordance with 1.1.6 of BS 9520. The individual reference number required by 1.1.6 3) consists of abbreviat

17、ions to identify individual connectors as follows: Packaging shall include the manufacturers assembly and contact replacement instructions. Full instructions for the removal and replacement of contacts and keys shall be provided by the manufacturer. Packages of replacement parts shall include an out

18、line drawing showing salient dimensions. Style number:As shown in A.2. This is the control drawing number with the prefix “CC/” deleted. Number of waysDigits denoting the number of contacts along one side of the connector. Single or double-sided and active contact row: A = single-sided, side A activ

19、e, single row of terminations B = single-sided, side B active, single row of terminations E = single-sided, side A active, double row of terminations F = single-sided, side B active, double row of terminations D = double-sided, both sides active Termination style:S = solder for wire W = wire wrap T

20、= through-board solder, short spill L = through-board solder, long spill X = through-board solder, extra long spill Contact finish:A = hard acid gold alloy Contact removal/replacement system: A = rear release/front removable contacts B = rear release/rear removable contacts C = front release/front r

21、emovable contacts D = front release/rear removable contacts Variant:Digits identifying an individual connector, parts and associated tools for replacement purposes. As in PD 9002. Example reference number: S 6002 85 D S A B XX Licensed Copy: London South Bank University, London South Bank University

22、, Fri Dec 08 04:30:12 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9526 N0003:1979 BSI 10-19993 5 Ordering information The following information is to be given when ordering parts to this specification: a) The number of this detail specification b) The individual (type) reference number as describe

23、d in clause 4 of this detail specification c) Details of marking which may be required in addition to that specified in clause 4 of this detail specification d) Details of any requirements, e.g. contact omission plans, additional contacts or keys, etc. 6 Outline drawings See Appendix A of this speci

24、fication for the following: A.1 Outline dimensions, mounting details and mass A.2 Termination styles and dimensions A.3 Printed board layouts and edge dimensions A.4 Test board details and dimensions A.5 Gauges NOTEOutline drawings include a cross-reference to the relevant National Supervising Inspe

25、ctorate control drawings. 7 Ratings 7.1 Electrical 7.1.1 Current a) Maximum current per individual contact (in isolation)1): b) Maximum current per contact through all contacts simultaneously: The performance of any connector listed in this specification at all times exceeds the maximum continuous r

26、ating of the appropriate printed board and the bunched rating of the appropriate wire or cable of equivalent temperature rating, and this rating shall be the determining factor. 7.1.2 Voltage At 25 C ambient temperature:3 A At 85 C ambient temperature:1.5 A 1) i.e. when only one contact per connecto

27、r is electrically loaded. At 25 C ambient temperature:1.5 A At 85 C ambient temperature:1.0 A Sea level 1 013 mbar 8 500 m 300 mbar Working voltagea (nominal) d.c. or a.c. peak 350250 Voltage proof d.c. or a.c. peak 1 050500 a Establishment of electrical safety factors is the responsibility of the u

28、ser. Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 04:30:12 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9526 N0003:1979 4 BSI 10-1999 7.2 Environmental 7.3 Endurance 8 Characteristics 8.1 Connector range. (See A.1 and A.2 of this specification) 8.2 Electrica

29、l 8.3 Mechanical 8.4 Fluid resistance The connectors shall be resistant to the following fluids listed in Appendix E of BS 9520. Isopropanol, 1, 1, 2-trichloro trifluoroethane, 1, 1, 1-trichloroethane, and trichloroethylene. Environmental classification55/125/21 Low air pressure severity300 mbar Vib

30、ration severitya10 Hz to 500 Hz, 0.75 mm/10gn, Duration 6 h Shock severityNA Acceleration severityNA Bump severity390 m/s2 (40gn) 1 000 10 bumps a The vibration test is carried out using an assessment board (see A.4 of this specification). In practice, the vibration performance will vary with the si

31、ze and weight of board used, and also with the method of mounting the connector. Mechanicala250 operations High temperature, long term current as in 6.1.1 2) 1 000 h at 85 C High temperature, short term (no electrical load) 250 h at 125 C a The mechanical endurance test is carried out using a gauge

32、(see A.5 of this specification). Endurance with a printed board is critically dependent upon the preparation of the board particularly the leading edge, and also the type of plating used. Maximum contact resistance (initially)15 m7 (using test gauge as in A.5.1) Maximum contact resistance (after con

33、ditioning) 20 m7 (using test gauge as in A.5.1) Minimum insulation resistance (initially)100 000 M7 (Method A) 1 000 M7 (Method B) Minimum insulation resistance (hot and after conditioning) 100 M7 (Method B) Engaging and separating force, connectora2.8 N (0.63 lbf) max. per contact pair 0.2 N (0.045

34、 lbf) min. per contact pair Contact retention (in insert moulding) Termination styles T, L, X and W20 N (4.50 lbf) min. Termination style S10 N (2.25 lbf) min. Contact holding force gauge mass15.3 g Guide key (locating) retention10 N (2.25 lbf) min. Static load (mating)4 N (0.90 lbf) per contact pai

35、r max. a These values must be multiplied by the number of contact pairs in a particular connector to obtain the total engaging and separating forces for that connector. Force values refer to the use of gauges. Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 04:3

36、0:12 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9526 N0003:1979 BSI 10-19995 9 Certified test records (CTRs) Certified test records shall be prepared in accordance with 1.1.11 of BS 9520. 10 Additional information 10.1 Guide keys (locating). It is possible for mismatching to occur with this range

37、 of connectors and the mating printed boards at extremes of tolerance, under the application of practical tolerancing, unless guide keys are used. Where practicable, guide keys should be situated near the centre of the connector. 10.2 Guide keys (polarizing). Polarization is effected by additional g

38、uide keys fitted by the user as required in place of contacts. (See A.3.1 of this specification.) 11 Quality assessment procedure Group C tests need not be carried out for Qualification Approval or when subsequent group D tests are performed. 12 Inspection requirements Samples subjected to tests in

39、subgroups marked “(D)” shall not be accepted for release under BS 9000 (see 2.6.5 of BS 9000-1). Unless otherwise specified, tests shall be performed at an ambient temperature of between 15 C and 35 C. Fitting and wiring of contacts shall be in accordance with the manufacturers instructions. Polytet

40、rafluoroethylene (PTFE) extruded insulation equipment wire to BS G 210 shall be used. (To ensure that the wiring operation has been carried out satisfactorily it is advisable to apply insulation resistance and contact resistance tests.) InspectionBS 9520 reference and conditions of testRequirements

41、as in BS 9520 GROUP ATo be applied on a sampling basis lot-by-lot except subgroups A0 Subgroups A2 and A3 are not applicable Subgroup A0100 % inspection Visual examination1.2.2 1)As in 1.2.2 1) Subgroup A1Inspection level S-3, AQL 1.5 % Visual examination1.2.2 2)As in 1.2.2 2) Subgroup A4Inspection

42、level S-3, AQL 1.5 % Voltage proof1.2.4.4Method A or B. Unmated. Voltage as specified in 6.1.2 of this specification. Duration 5 s As in 1.2.4.4 Subgroup A5 CTR information1.1.11The result of the test in subgroup A1 shall be reported as attributes information Licensed Copy: London South Bank Univers

43、ity, London South Bank University, Fri Dec 08 04:30:12 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9526 N0003:1979 6 BSI 10-1999 InspectionBS 9520 reference and conditions of testRequirements as in BS 9520 GROUP BTo be applied on a sampling basis lot-by-lot Subgroups B3 to B7 are not applicable Co

44、nnectors shall have contacts fitted and wired as required for tests Subgroup B1Inspection level S-4, AQL 1.5 % Insulation resistance Engaging and separating force, connector Contact holding force 1.2.4.3 1.2.5.2 1.2.5.8 Method A or B. (500 50 V) Forces as specified in 8.3 of this specification using

45、 gauges as prescribed in A.5 of this specification With 10 sizings and using gauges as prescribed in A.5 of this specification A 100 000 M7 min. B 1 000 M7 min. As in 1.2.5.2 As in 1.2.5.8 Subgroup B2 (D)Inspection level S-4, AQL 4 % Specimens from subgroup B1 may be used. Solderinga 1.2.6.6Method 1

46、 Recovery period 1 hSatisfactory tinning. No loosening of parts or other damage such as would impair performance Contact resistance1.2.4.1 1)Using gauges as prescribed in A.5 of this specification 15 m7 max. Subgroup B8 CTR information1.1.11Results from the tests in subgroups B1 and B2 shall be repo

47、rted as attributes information GROUP CTo be applied on a sampling basis at three-monthly intervals Subgroups C2, C3 and C4 are not applicable The issue number of the manufacturing drawing shall be checked against that on the approval certificate Subgroup C1Inspection level S-3, AQL 4 % Dimensions, o

48、utline1.2.3.1In addition wire wrap and through-board termination positions shall be checked using the gauges prescribed in A.5 of this specification Dimensions as specified in A.1 and A.2 of this specification. The terminations shall accept the gauges Subgroup C5 (D)Inspection level S-3, AQL 4 % Mec

49、hanical endurance1.2.7.1250 operations at 15 operations per minute maximum, using gauges as prescribed in A.5 of this specification a Applicable only to connectors having terminations intended to be soldered. Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 04:30:12 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9526 N0003:1979 BSI 10-19997 InspectionBS 9520 reference and conditions of testRequirements as in BS 9520 Subgroup C5 (D) High temperature endurance 1.2.7.2250 h duration at 125 C No electrical load and unm