1、BRITISH STANDARD BS EN 12775:2001 Solid wood panels Classification and terminology The European Standard EN 12775:2001 has the status of a British Standard ICS 79.060.99 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 08:5

2、7:05 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 12775:2001 This British Standard, having been prepared under the direction of the Sector Committee for Building and Civil Engineering, was published under the authority of the Standards Committee and comes into effect on 15 March 2001 BSI 03-2001

3、 ISBN 0 580 37056 9 National foreword This British Standard is the official English language version of EN 12775:2001. The UK participation in its preparation was entrusted to Technical Committee B/541, Wood-based panels, which has the responsibility to: A list of organizations represented on this c

4、ommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or b

5、y using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer imm

6、unity from legal obligations. aid enquirers to understand the text; present to the responsible European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. S

7、ummary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 7 and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. DateComments Licensed Copy: shef

8、fieldun sheffieldun, na, Sat Oct 28 08:57:05 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 12775 January 2001 ICS 01.040.79; 79.060.99 English version Solid wood panels - Classification and terminology Bois panneauts - Classification et terminologieM

9、assivholzplatten - Klassifizierung und Terminologie This European Standard was approved by CEN on 1 January 2001. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any a

10、lteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by tran

11、slation under the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, I

12、taly, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: rue de Stassart, 36 B-1050 Brussels 2001 CENAll rights of exploitation in any form a

13、nd by any means reserved worldwide for CEN national Members. Ref. No. EN 12775:2001 E Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 08:57:05 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 2 EN 12775:2001 Contents Page Foreword . . . . . . . . . . . . . . . . . . . . . . . . . . .2 1Scope .

14、 . . . . . . . . . . . . . . . . . . . . . . . .3 2Normative references . . . . . . . . . . . . .3 3Classification . . . . . . . . . . . . . . . . . . . .3 3.1According to the composition of the panel 3 3.2According to their principal characteristics 3 3.3According to their surface condition . . . .

15、4 3.4According to the ultimate user requirements 4 4Terms and definitions relating to solid wood panels . . . . . . . . . . . . . . . .4 4.1Solid wood panel . . . . . . . . . . . . . . . . . .4 4.2Large-sized panel . . . . . . . . . . . . . . . . .4 4.3Medium-sized panel . . . . . . . . . . . . . .

16、.5 4.4Panel cut to size . . . . . . . . . . . . . . . . . .5 4.5Length of panel . . . . . . . . . . . . . . . . . . .5 4.6Width of panel . . . . . . . . . . . . . . . . . . . .5 4.7Layer . . . . . . . . . . . . . . . . . . . . . . . . . .5 4.8Face . . . . . . . . . . . . . . . . . . . . . . . . . .5

17、 Page 4.9Back . . . . . . . . . . . . . . . . . . . . . . . . . .5 4.10 Strip . . . . . . . . . . . . . . . . . . . . . . . . . . .5 4.11 Board . . . . . . . . . . . . . . . . . . . . . . . . . .6 4.12 Lamella . . . . . . . . . . . . . . . . . . . . . . . .6 4.13 Blank . . . . . . . . . . . . . . .

18、. . . . . . . . . . .6 4.14 Plank . . . . . . . . . . . . . . . . . . . . . . . . . .6 4.15 Structure of wood . . . . . . . . . . . . . . . . .6 4.16 Narrow-ringed wood . . . . . . . . . . . . . . .6 4.17 Wide-ringed wood . . . . . . . . . . . . . . . . .6 4.18 Straight-grain wood . . . . . . . . .

19、. . . . . . .6 4.19 Presence of knots . . . . . . . . . . . . . . . . .6 4.20 Black knot . . . . . . . . . . . . . . . . . . . . . .6 4.21 Patch . . . . . . . . . . . . . . . . . . . . . . . . . .6 4.22 Natural plug . . . . . . . . . . . . . . . . . . . . .7 4.23 Serial plugging . . . . . . . . . .

20、. . . . . . . . .7 4.24 Chemical patching . . . . . . . . . . . . . . . . .7 4.25 Worm hole . . . . . . . . . . . . . . . . . . . . . .7 4.26 Fungal attack . . . . . . . . . . . . . . . . . . . .7 4.27 Fine-sawn timber . . . . . . . . . . . . . . . . . .7 4.28 Sanded timber . . . . . . . . . . . . .

21、 . . . . . .7 4.29 End joint . . . . . . . . . . . . . . . . . . . . . . . .7 4.30 Simple butt . . . . . . . . . . . . . . . . . . . . . .7 Foreword This European Standard has been prepared by Technical Committee CEN/TC 112 “Wood-based panels“, the secretariat of which is held by DIN. This European

22、Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by July 2001, and conflicting national standards shall be withdrawn at the latest by July 2001. According to the CEN/CENELEC Internal Regulations, the national stand

23、ards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and the United Kingdom. No existing

24、 European Standard is superseded. Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 08:57:05 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 3 EN 12775:2001 1 Scope This European standard gives a classification for solid wood panels and defines terms used with solid wood panels. 2 Normative ref

25、erences This European Standard incorporates, by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of

26、these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references, the latest edition of the publication referred to applies (including amendments). EN 844-3 Round and sawn timber Terminology Part 3: General terms relating to sawn timber

27、 EN 844-7 Round and sawn timber Terminology Part 7: Terms relating to anatomical structure of timber EN 844-9 Round and sawn timber Terminology Part 9: Terms relating to features of sawn timber EN 844-10 Round and sawn timber Terminology Part 10: Terms relating to stain and fungal attack EN 844-11 R

28、ound and sawn timber Terminology Part 11: Terms relating to degrade by insects 3 Classification 3.1 According to the composition of the panel a) Single-layer panels b) Multi-layer panels 3.2 According to their principal characteristics 3.2.1 According to their conditions of use a) Panels for use in

29、dry conditions b) Panels for use in humid conditions c) Panels for use in exterior conditions 3.2.2 According to their mechanical properties a) Panels for general purposes b) Panels for structural uses 3.2.3 According to their surface appearance 3.2.3.1 According to the group of wood species in the

30、outer layer a) Softwood panels b) Hardwood panels Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 08:57:05 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 4 EN 12775:2001 3.2.3.2 According to the length of pieces in the outer layer a) Panels with pieces cut to length (“SC“ showing cuts). b) P

31、anels with pieces not cut to length (“NC no cuts) 3.3 According to their surface condition a) Raw panels b) Sanded panels c) Panels with textured surfaces d) Finished panels (e.g. overlaid, coated, primed, varnished, oil treated) 3.4 According to the ultimate user requirements 4 Terms and definition

32、s relating to solid wood panels For the purpose of this standard, the terms and definitions given in EN 844-3, EN 844-7, EN 844-9, EN 844-10 and EN 844-11 and the following apply. NOTE In the following definitions “pieces of timber“ means timber in the form of boards, lamellas, blanks, strips or pla

33、nks. 4.1 Solid wood panel Panel that consists of pieces of timber glued edge-to-edge and, if multi-layer, face-to-face. 4.1.1 Single-layer solid wood panel Solid wood panel, consisting of several pieces of timber which are glued together to form one layer. 4.1.1.1 Solid wood panel with pieces cut to

34、 length Solid wood panel with pieces of timber which show cuts across their length and, as a rule, are glued together at their ends or finger-jointed (Type “SC“). 4.1.1.2 Solid wood panel with pieces not cut to length Solid wood panel consisting of pieces of timber which are undivided for the full l

35、ength of the panel (Type “NC“). 4.1.2 Multi-layer solid wood panel Solid wood panel, consisting of two outer layers with their grain direction running parallel and at least one inner layer with its grain direction at 90 to the outer layers. 4.2 Large-size panel Panel with dimensions equal to or grea

36、ter than 3 m in length and equal to or greater than 1 m in width. Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 08:57:05 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 5 EN 12775:2001 4.3 Medium-sized panel Panel with dimensions less than 3 m in length or less than 1 m in width. 4.4 Panel

37、cut to size Panel which conforms to the size specified by the purchaser. 4.5 Length of panel The panel dimension in the direction of the grain of the outer layers. 4.6 Width of panel The panel dimension at right angles to the length 4.7 Layer Flat composition of pieces of timber which can be glued e

38、dge-to-edge and eventually end-to-end. 4.7.1 Outer layer Outside stratum of a multi-layer solid wood panel. 4.7.2 Inner layer Any stratum of a multi-layer solid wood panel which is not an outer layer. 4.7.3 Middle layer Central stratum of a multi-layer solid wood panel. 4.8 Face The surfaces which f

39、all in the better appearance class. NOTE If both surfaces fall in the same class, the panel can be considered to having two faces and no back. 4.9 Back The surface of the panel which falls in the lower appearance class (compared to the face). 4.10 Strip Piece of sawn timber of longish form, less tha

40、n 40 mm in thickness and less than 80 mm in width. Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 08:57:05 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 6 EN 12775:2001 4.11 Board Piece of sawn timber of longish form, less than 40 mm in thickness (but not less than 10 mm thick) and more th

41、an 80 mm in width. 4.12 Lamella Piece of sawn timber of longish form between 3 mm and 10 mm in thickness and of 25 mm or more in width. 4.13 Blank Piece of sawn timber of longish form which is more than 40 mm in thickness and not exceeding 80 mm in width. 4.14 Plank Piece of sawn timber of longish f

42、orm which is 40 mm or more in thickness and more than 80 mm in width. 4.15 Structure of wood Anatomic composition of wood, determined by the size and type of cells, pores and the width and regularity of growth rings. 4.16 Narrow-ringed wood Wood with close growth rings. With softwood species, the wo

43、od is narrow-ringed if it has an average of 6 or more growth rings per 1 cm over the whole cross section. 4.17 Wide-ringed wood Wood with large growth rings. Wood is wide-ringed if the average width of the growth rings (measured radially at the cross section) exceeds 6 mm. 4.18 Straight-grain wood W

44、ood with a slope of grain of less than 2 cm/m. 4.19 Presence of knots Term which describes the existence of knots in a piece of timber. 4.20 Black knot Unsound knot or dead knot with black discolouration at the whole or in part (ring-shaped) of its cross-section. 4.21 Patch Small flat piece of wood

45、used for inserting into a piece of sawn timber, or a solid wood panel, to replace visible parts of features such as knots or defects. Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 08:57:05 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 7 EN 12775:2001 4.22 Natural plug Plug which has been

46、produced from a natural branch and therefore shows the complete circular growth rings across its surface. 4.23 Serial-plugging Insertion of plugs separated by a distance less than their individual width or even overlapping. 4.24 Chemical patching Defect filled with a chemical compound. 4.25 Worm hol

47、e Borehole in wood with a diameter of more than 2 mm. 4.26 Fungal attack Discolouration and/or structural alteration of wood by the attack of wood-destroying or wood-discolouring fungi. 4.27 Fine-sawn timber Timber which has been worked with a fine cut circular saw or fine-cut band saw in such a way

48、 that the rough- ness depth does not exceed 0,5 mm. 4.28 Sanded timber Timber which has been finished by machine with sanding belts. 4.29 End joint Connection of two pieces of timber end-to-end either by glueing (finger or butt-jointed) or by mechanical fasteners (e.g. corrugated fasteners). 4.30 Si

49、mple butt Jointing of two pieces of timber without glued or mechanical connection. Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 08:57:05 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 12775:2001 BSI 389 Chiswick High Road London W4 4AL BSI British Standards Institution BSI is the independent national body responsible for preparing British Standards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter. Revisions British Standards are updated by amendment or revision. Users of B