1、| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | BRITISH STANDARD BS EN 12976-1:2001 The Eu

2、ropean Standard EN 12976-1:2000 has the status of a British Standard ICS 27.160 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW Thermal solar systems and components Factory made systems Part 1: General requirements Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 07:14:3

3、4 GMT+00:00 2006, Uncontrolled Copy, (c) BSI This British Standard, having been prepared under the direction of the Engineering Sector Committee, was published under the authority of the Standards Committee and comes into effect on 15 February 2001 BSI 02-2001 ISBN 0 580 36860 2 BS EN 12976-1:2001 A

4、mendments issued since publication Amd. No.DateComments National foreword This British Standard is the official English language version of EN 12976-1:2000. The UK participation in its preparation was entrusted to Technical Committee RHE/25, Solar heating, which has the responsibility to: aid enquir

5、ers to understand the text; present to the responsible European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. A list of organizations represented on th

6、is committee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled International Standards Correspondence Index, or

7、 by using the Find facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer imm

8、unity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 16, an inside back cover and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued. Licensed Copy: sheffi

9、eldun sheffieldun, na, Sat Oct 28 07:14:34 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 12976-1 December 2000 ICS 27.160 English version Thermal solar systems and components - Factory made systems - Part 1: General requirements Installations solaire

10、s thermiques et leurs composants - Installations prfabriques en usine - Partie 1: Exigences gnrales Thermische Solaranlagen und ihre Bauteile - Vorgefertigte Anlagen - Teil 1: Allgemeine Anforderungen This European Standard was approved by CEN on 24 November 2000. CEN members are bound to comply wit

11、h the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Management Centre

12、 or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the official vers

13、ions. CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN

14、DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: rue de Stassart, 36 B-1050 Brussels 2000 CENAll rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 12976-1:2000 E Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 07:14:

15、34 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 2 EN 12976-1:2000 Contents Page Foreword .3 Introduction.4 1Scope .6 2Normative references .6 3Terms and definitions.7 4Requirements7 4.1General .7 4.1.1Suitability for drinking water7 4.1.2Water contamination.7 4.1.3Freeze resistance .7 4.1.4Overte

16、mperature protection8 4.1.5Reverse flow protection.8 4.1.6Pressure resistance 8 4.2Materials9 4.3Components and pipework .9 4.3.1Collector9 4.3.2Supporting frame.9 4.3.3Piping 9 4.3.4Circulation pump.10 4.3.5Heat Exchangers.10 4.3.6Store10 4.3.7Control system10 4.4Safety equipment10 4.4.1Safety valv

17、es.10 4.4.2Safety lines and expansion lines.10 4.4.3Blow-off lines.10 4.5Resistance to external influences .11 4.6Documentation11 4.6.1General .11 4.6.2Documents for the installer .11 4.6.3Documents for the user.12 4.7Marking .13 4.8System performance.13 Annex A (informative) Conformity assessment .

18、14 Bibliography16 Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 07:14:34 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 3 EN 12976-1:2000 Foreword This European Standard has been prepared by Technical Committee CEN/TC 312 “Thermal solar systems and components“, the secretariat of which is

19、held by ELOT. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by June 2001, and conflicting national standards shall be withdrawn at the latest by June 2001. According to the CEN/CENELEC Internal Reg

20、ulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and the

21、 United Kingdom. Annex A is informative. Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 07:14:34 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 4 EN 12976-1:2000 Introduction Drinking water quality In respect of potential adverse effects on the quality of water intended for human consumptio

22、n, caused by the product covered by this standard: a) This standard provides no information as to whether the product may be used without restriction in any of the Member States of the EU or EFTA; b) It should be noted that, while awaiting the adoption of verifiable European criteria, existing natio

23、nal regulations concerning the use and/or the characteristics of this product remain in force. Factory Made and Custom Built solar heating systems The standards EN 12976-1:2000 as well as EN 12976-2:2000 and the prestandards prENV 12977-1:2000 to prENV 12977-3:2000 distinguish two categories of sola

24、r heating systems: Factory Made solar heating systems and Custom Built solar heating systems. The classification of a system as Factory Made or Custom Built is a choice of the final supplier, in accordance with the following definitions. Factory Made solar heating systems are batch products with one

25、 trade name, sold as complete and ready to install kits, with fixed configurations. Systems of this category are considered as a single product and assessed as a whole. If a Factory Made Solar Heating System is modified by changing its configuration or by changing one or more of its components, the

26、modified system is considered as a new system for which a new test report is necessary. Requirements and test methods for Factory Made solar heating systems are given in EN 12976- 1:2000 and EN 12976-2:2000. Custom Built solar heating systems are either uniquely built, or assembled by choosing from

27、an assortment of components. Systems of this category are regarded as a set of components. The components are sepa- rately tested and test results are integrated to an assessment of the whole system. Requirements for Custom Built solar heating systems are given in prENV 12977-1:2000, test methods ar

28、e specified in prENV 12977- 2:2000 and prENV 12977-3:2000. Custom Built solar heating systems are subdivided into two categories: - Large Custom Built systems are uniquely designed for a specific situation. In general HVAC engineers, manufacturers or other experts design them. - Small Custom Built s

29、ystems offered by a company are described in a so-called assortment file, in which all components and possible system configurations, marketed by the company, are specified. Each possible combination of a system configuration with components from the assortment is considered as one Custom Built syst

30、em. Table 1 shows the division for different system types: Table 1 - Division for factory made and custom built solar heating systems Factory Made Solar Heating Systems (EN 12976-1, -2) Custom Built Solar Heating Systems (ENV 12977-1, -2, -3) Integral collector-storage systems for domestic hot water

31、 preparation Forced-circulation systems for hot water preparation and/or space heating, assembled using components Thermosiphon systems for domestic hot water preparation and configurations described in a documentation file (mostly small systems) Forced-circulation systems as batch product with fixe

32、d configuration for domestic hot water preparation Uniquely designed and assembled systems for hot water preparation and/or space heating (mostly large systems) Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 07:14:34 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 5 EN 12976-1:2000 NOTE 1 Fo

33、rced circulation systems can be classified either as Factory Made or as Custom Built, depending on the market approach chosen by the final supplier. NOTE 2 Both Factory Made and Custom Built systems are performance tested under the same set of reference conditions as specified in annex B of EN 12976

34、-2:2000 and annex A of prENV 12977-2:2000. In practice, the in- stallation conditions may differ from these reference conditions. NOTE 3 A Factory Made system for domestic hot water preparation may have an option for space heating, how- ever this option should not be used or considered during testin

35、g as a Factory Made system. Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 07:14:34 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 6 EN 12976-1:2000 1 Scope This European Standard specifies requirements on durability, reliability and safety for Factory Made thermal solar heating systems. Th

36、e standard also includes provisions for evaluation of conformity to these require- ments. The requirements in this standard apply to Factory Made solar systems as products. The installation of these systems itself is not considered, but requirements are given for the documentation for the installer

37、and the user which is delivered with the system (see also the clause 3). 2 Normative references This European Standard incorporates, by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are

38、listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies (including amendments). E

39、N 307, Heat exchangers Guidelines to prepare installation, operating and maintenance instructions required to maintain the performance of each type of heat exchanger prEN 806-1:1999, Specifications for installations inside buildings conveying water for human consumption Part 1: General EN 809, Pumps

40、 and pump units for liquids General safety requirements EN 1151, Pumps Rotodynamic pumps Circulation pumps having an electrical effect not exceeding 200 W for heating installations and domestic hot water installations Requirements, testing, marking EN 1489, Building valves Pressure safety valve Test

41、s and requirements EN 1490, Building valves Combined temperature and pressure relief valves Tests and requirements prEN 1717:1999, Protection against pollution of potable water in drinking water installations and general requirements of devices to prevent pollution by backflow ENV 1991-2-3, Eurocode

42、 1 Basis of design and actions on structures Part 2 - 3: Action on structures - Snow loads ENV 1991-2-4, Eurocode 1: Basis of design and actions on structures Part 2 - 4: Action on structures - Wind loads prEN 12897:1997, Water supply Specification for indirectly heated unvented (closed) hot water s

43、torage systems EN 12975-1:2000, Thermal solar systems and components Solar collectors Part 1: General require- ments prEN 12975-2:2000, Thermal solar systems and components Solar collectors Part 2: Test methods EN 12976-2:2000, Thermal solar systems and components Factory made systems Part 2: Test m

44、ethods EN 60335-1, Safety of household and similar electrical appliances Part 1: General requirements (IEC 60335-1:1991 modified) EN 60335-2-21, Safety of household and similar electrical appliances Part 2: Particular requirements for storage water heaters (IEC 60335-2-21:1997 + Corrigendum 1998, mo

45、dified) ENV 61024-1, Protection of structures against lightning Part 1: General principles (IEC 61024-1:1990, modified) EN ISO 9488, Solar energy Vocabulary (ISO 9488:1999) ISO/TR 10217, Solar energy Water heating systems Guide to material selection with regard to internal corrosion Licensed Copy: s

46、heffieldun sheffieldun, na, Sat Oct 28 07:14:34 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 7 EN 12976-1:2000 3 Terms and definitions For the purposes of this standard, the terms and definitions given in EN ISO 9488 apply, together with the following additional definition: Factory Made solar sys

47、tem A packaged solar energy system for the purpose of hot water preparation only, either of the close-coupled or remote-store type. The system consists of either one integral component or of a uniform set and configuration of components. It is produced under conditions, which are presumed uniform, a

48、nd offered for sale under the same trade name. NOTE 1 A single system can be tested as a whole in a test laboratory, leading to representative results for all systems with the same trade name, configuration, components and dimensions (see also the In- troduction). NOTE 2 External auxiliary water hea

49、ting devices that are placed in series with the Factory Made system are not considered to be part of the system. Cold water piping from the cold water grid to the system as well as piping from the system to an external auxiliary heater or to tapping points is not considered to be part of the system. Piping between components of the Factory Made system is considered to be part of the system. Any integrated heat exchanger or piping for space heating option (see Introduction, NOTE 3) is not con- sidered to be part o