1、BRITISH STANDARD BS EN 13286-5:2003 Unbound and hydraulically bound mixtures Part 5: Test methods for laboratory reference density and water content Vibrating table The European Standard EN 13286-5:2003 has the status of a British Standard ICS 93.080.20 ? Licensed Copy: sheffieldun sheffieldun, na,

2、Mon Oct 30 09:34:30 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 13286-5:2003 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 18 March 2003 BSI 18 March 2003 ISBN 0 580 41411 6 National foreword This British Standard is the official Engli

3、sh language version of EN 13286-5:2003. The UK participation in its preparation was entrusted by Technical Committee B/510, Road materials, to Subcommittee B/510/4, Cementitious bound materials, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained

4、 on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of t

5、he BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid en

6、quirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This d

7、ocument comprises a front cover, an inside front cover, the EN title page, pages 2 to 14, an inside back cover and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. DateComments Licensed Copy: she

8、ffieldun sheffieldun, na, Mon Oct 30 09:34:30 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 13286-5 March 2003 ICS 93.080.20 English version Unbound and hydraulically bound mixtures - Part 5: Test methods for laboratory reference density and water co

9、ntent - Vibrating table Mlanges traits et mlanges non traits aux liants hydrauliques - Partie 5: Mthodes dessai pour la masse volumique de rfrence et la teneur en eau en laboratoire - Table vibrante Ungebunden und hydraulisch gebundene Gemische - Teil 5: Laborprfverfahren fr die Trockendichte und de

10、n Wassergehalt - Vibrationstisch This European Standard was approved by CEN on 12 December 2002. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-

11、date lists and bibliographical references concerning such national standards may be obtained on application to the Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the

12、 responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Lu

13、xembourg, Malta, Netherlands, Norway, Portugal, Slovak Republic, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: rue de Stassart, 36 B-1050 Brussels 2003 CENAll rights of exploitati

14、on in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13286-5:2003 E Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 09:34:30 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 13286-5:2003 (E) 2 Contents page Foreword3 1Scope 5 2Normative references 5 3Terms and

15、 definitions5 4Principle5 5Apparatus .5 6Sampling.9 7Procedure .9 8Calculation and expression of results.10 9Test report 11 10Precision.11 Annex A (normative) Calibration of moulds12 Bibliography14 Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 09:34:30 GMT+00:00 2006, Uncontrolled Copy, (c)

16、 BSI EN 13286-5:2003 (E) 3 Foreword This document (EN 13286-5:2003) has been prepared by Technical Committee CEN/TC 227 “Road Materials“, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by

17、 endorsement, at the latest by September 2003, and conflicting national standards shall be withdrawn at the latest by December 2003. This European Standard is one of a series of standards as follows: EN 13286-1, Unbound and hydraulically bound mixtures Part 1: Test methods for laboratory reference d

18、ensity and water content Introduction, general requirements and sampling. prEN 13286-2, Unbound and hydraulically bound mixtures Part 2: Test methods for laboratory reference density and water content Proctor compaction. EN 13286-3, Unbound and hydraulically bound mixtures Part 3: Test methods for l

19、aboratory reference density and water content Vibrocompression with controlled parameters. EN 13286-4, Unbound and hydraulically bound mixtures Part 4: Test methods for laboratory reference density and water content Vibrating hammer. EN 13286-5, Unbound and hydraulically bound mixtures Part 5: Test

20、methods for laboratory reference density and water content Vibrating table. prEN 13286-7, Unbound and hydraulically bound mixtures Part 7: Cyclic load triaxial test for unbound mixtures. EN 13286-40, Unbound and hydraulically bound mixtures Part 40: Test method for the determination of the direct te

21、nsile strength of hydraulically bound mixtures. EN 13286-41, Unbound and hydraulically bound mixtures Part 41: Test methods for the determination of the compressive of strength of hydraulically bound mixtures. EN 13286-42, Unbound and hydraulically bound mixtures Part 42: Test method for the determi

22、nation of the indirect tensile strength of hydraulically bound mixtures. EN 13286-43, Unbound and hydraulically bound mixtures Part 43: Test method for the determination of the modulus of elasticity of hydraulically bound mixtures. prEN 13286-44, Unbound and hydraulically bound mixtures Part 44: Tes

23、t method for the determination of the alpha coefficient of vitrified blastfurnace slag. prEN 13286-45, Unbound and hydraulically bound mixtures Part 45: Test method for the determination of the workability period of hydraulically bound mixtures. EN 13286-46, Unbound and hydraulically bound mixtures

24、Part 46: Test method for the determination of the moisture condition value. prEN 13286-47, Unbound and hydraulically bound mixtures Part 47: Test method for the determination of California bearing ratio, immediate bearing index and linear swelling. prEN 13286-48, Unbound and hydraulically bound mixt

25、ures Part 48: Test method for the determination of the degree of pulverisation. Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 09:34:30 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 13286-5:2003 (E) 4 prEN 13286-49, Unbound and hydraulically bound mixtures Part 49: Test method for the determ

26、ination of the accelerated swelling of soil treated by lime and/or hydraulic binder. prEN 13286-50, Unbound and hydraulically bound mixtures Part 50: Method for the manufacture of test specimens of hydraulically bound mixtures using Proctor equipment or vibrating table compaction. prEN 13286-51, Unb

27、ound and hydraulically bound mixtures Part 51: Method for the manufacture of test specimens of hydraulically bound mixtures using vibrating hammer compaction. prEN 13286-52, Unbound and hydraulically bound mixtures Part 52: Method for the manufacture of test specimens of hydraulically bound mixtures

28、 using vibrocompression. prEN 13286-53, Unbound and hydraulically bound mixtures Part 53: Method for the manufacture of test specimens of hydraulically bound mixtures using axial compression. Annex A is normative. According to the CEN/CENELEC Internal Regulations, the national standards organization

29、s of the following countries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovak Republic, Spain, Sweden, Switzerland and the United King

30、dom. Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 09:34:30 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 13286-5:2003 (E) 5 1 Scope This European Standard specifies a method for the determination of the maximum dry density and water content of cohesionless materials when compacted using a

31、vibrating table. The method utilizes vibratory compaction to obtain maximum density under saturated conditions. Materials for which this method is applicable may contain up to 12 % by mass fines ( 80 mm and weigh them. Record their mass S. 7 Procedure Weigh the empty mould with the surcharge base pl

32、ate and record the mass U. Determine the maximum density as follows. If water is added to the dry material allow a sufficient soaking period. For traditional road materials the soaking period shall be at least 30 min. Fill the mould with moist material by means of a shovel. Add sufficient water to t

33、he material to allow a small amount of free water to accumulate on the surface of the material during filling. During and just after filling the mould, vibrate the material for a total of 360 s while the amplitude of the vibrator is reduced as much as necessary to avoid excessive boiling and fluffin

34、g of the material. During the final minute of vibration, remove any water appearing above the surface of the material. Fasten the guide sleeve to the surcharge base plate and place them upon the surface of the specimen. Lower the surcharge balance on the surcharge base plate using a tackle arrangeme

35、nt. Adjust the amplitude control of the vibratory table so that the amplitude of the mould is (0,40 0,05) mm (half of length of stroke) and vibrate the specimen for (720 15) s. After the vibration period, remove the surcharge balance and guide sleeve from the mould. Measure the distance from the top

36、 of the mould to the surcharge base plate by slide gauge at four locations. Calculate the average of the four measurements and record the result R. Obtain the measurement so that it is: positive when the plate is below the edge of the mould; and negative when the plate is above the edge. Wipe away a

37、ny mud which has appeared on the surcharge base plate and the mould. Weigh the mould together with the surcharge base plate and the vibrated material. Record the mass T. Remove the entire specimen from the mould. Weigh the specimen and record the mass JW. Dry the specimen to constant mass in accorda

38、nce with EN 1097-5. Weigh the dried specimen and record the mass mD. Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 09:34:30 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 13286-5:2003 (E) 10 8 Calculation and expression of results 8.1Determine the water content by means of the following: w =

39、 100 (mW mD)/mD(1) where wis the water content, in percent (%); mWis the wet mass of the material, in grams (g); mDis the mass of the dried material, in grams (g). mW = T U(2) where mWis the wet mass of the material, in grams (g); Tis the total mass of the wet material and the mould and the surcharg

40、e base plate, in grams (g); Uis the mass of the mould and the surcharge base plate, in grams (g). 8.2Determine the maximum dry density as follows: d,max = mW/(1 + w/100)VJ(3) where mwis the wet mass of the material, in grams (g); d,maxis the maximum dry density, in megagrams per cubic metre (Mg/m3);

41、 VJis the volume of the material, in millilitres (ml). VJ = VF (H + R) Ar; VFis the volume of the mould, in millilitres (ml); Ris the average of the slide gauge readings (with signs) after the vibration period, in millimetres (mm); His the thickness of the surcharge base plate, in millimetres (mm);

42、Aris the cross section area of the mould, in square millimetres (mm2). mW = T U(4) mwis the wet mass of the material, in grams (g); Tis the total mass of the wet material and the mould and the surcharge base plate, in grams (g); Uis the mass of the mould and the surcharge base plate, in grams (g). V

43、J = VF (H + R) Ar(5) where VJis the volume of the material, in millilitres (ml); Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 09:34:30 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 13286-5:2003 (E) 11 VFis the volume of the mould, in millilitres (ml); His the thickness of the surcharge bas

44、e plate, in millimetres (mm); Ris the average of the slide gauge readings (with signs) after the vibration period, in millimetres (mm); Aris the cross section area of the mould, in square millimetres (mm2). 8.3Determine the content of particles 80 mm as follows: s = 100 S/P(6) where sis the aggregat

45、e content by the current water content of the material, in percent (%); Sis the mass of aggregate 80 mm, in kilograms (kg); Pis the mass of the total sample, in kilograms (kg). NOTEs is calculated only for information. d,max is thus not corrected for content of aggregate 80 mm. 9 Test report The tes

46、t report shall include at least the following information: a) reference to this European Standard; b) identification of the sample; c) identification of the laboratory; d) date; e) maximum dry density, d,max, in megagrams per cubic metre to two decimal places; f) corresponding water content, w, in p

47、ercentage; the determination shall be given to one decimal place; g) aggregate content by the current water content of the material, s 80 mm in percentage. If required, the test report shall include the following optional information: h) name and location of the sample source; i) description of the

48、material. 10 Precision To be added later. Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 09:34:30 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 13286-5:2003 (E) 12 Annex A (normative) Calibration of moulds A.1 Calibration interval The calibration interval shall be after every 1 000 tests or

49、annually whichever occurs first. A.2 Moulds A.2.1 Requirements Moulds shall be of the following dimensions: Height:(230 2) mm; Diameter:(280 2) mm. A.2.2 Apparatus A.2.2.1 Balance. A.2.2.2 Steel ruler. A.2.2.3Glass plate, of dimensions 300 mm 300 mm, with a 10 mm hole in the centre. A.2.2.4Slide gauge. A.2.3 Procedure Measure the height and the diameter of the mould with a slide gauge or a ruler at