1、BRITISH STANDARD BS EN 50382-2:2008 Railway applications Railway rolling stock high temperature power cables having special fire performance Part 2: Single core silicone rubber insulated cables for 120 C or 150 C ICS 13.220.40; 29.060.20; 45.060.01 ? BS EN 50382-2:2008 This British Standard was publ

2、ished under the authority of the Standards Policy and Strategy Committee on 30 May 2008 BSI 2008 ISBN 978 0 580 63043 9 National foreword This British Standard is the UK implementation of EN 50382-2:2008. The UK participation in its preparation was entrusted by Technical Committee GEL/20, Electric c

3、ables, to Subcommittee GEL/20/12, Railway cables. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance

4、with a British Standard cannot confer immunity from legal obligations. Amendments/corrigenda issued since publication DateComments EUROPEAN STANDARD EN 50382-2 NORME EUROPENNE EUROPISCHE NORM March 2008 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation El

5、ectrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50382-2:2008 E ICS 13.220.40; 29.060.20; 45.060.01 Eng

6、lish version Railway applications - Railway rolling stock high temperature power cables having special fire performance - Part 2: Single core silicone rubber insulated cables for 120 C or 150 C Applications ferroviaires - Cbles pour matriel roulant ferroviaire ayant des performances particulires de

7、comportement au feu - Partie 2: Cbles monoconducteurs isols au silicone pour 120 C ou 150 C Bahnanwendungen - Hochtemperaturkabel und -leitungen fr Schienenfahrzeuge mit verbessertem Verhalten im Brandfall - Teil 2: Einadrige silikonisolierte Leitungen fr 120 C oder 150 C This European Standard was

8、approved by CENELEC on 2008-02-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such

9、national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own lan

10、guage and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, La

11、tvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 50382-2:2008 2 Foreword This European Standard was prepared for the Technical Committee CENELEC TC 20, Electric cables, by Working Group 1

12、2, Railway Cables, as part of the overall programme of work in the Technical Committee CENELEC TC 9X, Electrical and electronic applications for railways. The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50382-2 on 2008-02-01. The following dates were fixed: l

13、atest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2009-02-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2011-02-01 BS EN 50382-2:2008 3 EN 50382-2:2008 Conten

14、ts Introduction 4 1 Scope 5 2 Normative references . 5 3 Definitions 6 4 Rated voltage . 6 5 Marking and identification . 6 5.1 Marking of cable . 6 5.2 Colour identification 7 6 Construction of cables 7 6.1 General . 7 6.2 Conductor . 7 6.3 Conductor screening . 7 6.4 Separator 7 6.5 Insulation sys

15、tem 8 6.6 Sheath 8 6.7 Textile braid 8 6.8 Constructional components . 9 7 Tests . 15 7.1 Definitions relating to tests 15 7.2 Conductor resistance 15 7.3 Voltage test 15 7.4 Insulation resistance . 15 7.5 Dielectric strength . 16 7.6 Spark test . 16 7.7 D.C. stability . 16 7.8 Surface resistance 16

16、 7.9 Ageing test . 17 7.10 Long term ageing test . 17 7.11 Hot set test . 17 7.12 Compatibility . 17 7.13 Water absorption test 17 7.14 Ozone resistance 18 7.15 Mineral oil resistance 18 7.16 Acid Part 2: Single core silicone rubber insulated cables for 120 C or 150 C. Special test methods referred

17、to in EN 50382 are given in EN 50305. A Guide to Use is given in EN 50355. Information regarding selection and installation of cables, including current ratings can be found in EN 50355 and EN 50343. The procedure for selection of conductor cross-sectional area, including reduction factors for ambie

18、nt temperature and installation type, is described in EN 50343. NOTE Current ratings for inclusion in EN 50355 are under development for the next amendment. Part 1, General requirements, contains a more extensive introduction to EN 50382, and should be read in conjunction with this Part 2. BS EN 503

19、82-2:2008 5 EN 50382-2:2008 1 Scope Part 2 of EN 50382 specifies requirements for, and constructions and dimensions of, single core cables of the following types and voltage ratings: 1,8/3 kV unscreened, unsheathed with or without textile braid (1,5 mm to 400 mm); 1,8/3 kV unscreened, sheathed (1,5

20、mm to 400 mm); 3,6/6 kV unscreened, unsheathed with or without textile braid (2,5 mm to 400 mm); 3,6/6 kV unscreened, sheathed (2,5 mm to 400 mm). All cables have class 5 or class 6 tinned or plain copper conductors to EN 60228, halogen-free insulation and where applicable halogen-free sheath. They

21、are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 120 C or 150 C and a maximum temperature for short circuit conditions of either 250 C or 350 C based on a d

22、uration of 5 s. When the insulating compounds and sheath specified in this standard which are thermally capable of operating at 150 C are used with tinned conductors, the maximum operating temperature is limited to 120 C and, for the same technical reason, the maximum short circuit temperature is li

23、mited to 250 C. The choice of sheath may also limit the maximum operating temperature to 120 C. A textile braid may be included in the insulation or applied at its surface to unsheathed cables. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permiss

24、ible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. This Part 2 of EN 50382 should be used in conjunction with Part 1 “General requirements”. 2 Normative references The following referenced documents are indispensable for the application of this document.

25、 For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 10002-1 Metallic materials Tensile testing Part 1: Method of test (at ambient temperature) EN 50266-2-4 Common test methods for cables u

26、nder fire conditions Test for vertical flame spread of vertically-mounted bunched wires or cables Part 2-4: Procedures Category C EN 50266-2-5 Common test methods for cables under fire conditions Test for vertical flame spread of vertically-mounted bunched wires or cables Part 2-5: Procedures Small

27、cables - Category D EN 50305:2002 Railway applications Railway rolling stock cables having special fire performance Test methods EN 50382-1 Railway applications Railway rolling stock high temperature power cables having special fire performance Part 1: General requirements EN 50395:2005 Electrical t

28、est methods for low voltage energy cables EN 60228 Conductors of insulated cables (IEC 60228) EN 60332-1-2 Tests on electric and optical fibre cables under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable Procedure for 1 kW pre-mixed flame (IEC 60332

29、-1-2) BS EN 50382-2:2008 EN 50382-2:2008 6 EN 60811-1-1:1995 Insulating and sheathing materials of electric and optical cables Common test methods Part 1-1: General application Measurement of thickness and overall dimensions Tests for determining the mechanical properties (IEC 60811-1-1:1993) EN 608

30、11-1-2:1995 Insulating and sheathing materials of electric cables Common test methods Part 12: General application Thermal ageing methods (IEC 60811-1-2:1985 + A1:1989 + corr. May 1986) EN 60811-1-3:1995 Insulating and sheathing materials of electric and optical cables Common test methods Part 1-3:

31、General application Methods for determining the density Water absorption tests Shrinkage test (IEC 60811-1-3:1993) EN 60811-1-4:1995 Insulating and sheathing materials of electric and optical cables Common test methods Part 14: General application Tests at low temperature (IEC 60811-1-4:1985 + A1:19

32、93 + corr. May 1986) EN 60811-2-1:1998 Insulating and sheathing materials of electric and optical cables Common test methods Part 21: Methods specific to elastomeric compounds Ozone resistance, hot set and mineral oil immersion tests (IEC 60811-2-1:1998) EN 61034-2 Measurement of smoke density of ca

33、bles burning under defined conditions Part 2: Procedure and requirements (IEC 61034-2) HD 308 Identification of cores in cables and flexible cords 3 Definitions For the purposes of this document, the terms and definitions given in EN 50382-1 apply. 4 Rated voltage The rated voltage for single core s

34、ilicone insulated cables shall be as follows: a) unsheathed: 1,8/3 kV; 3,6/6 kV; b) sheathed: 1,8/3 kV; 3,6/6 kV. 5 Marking and identification 5.1 Marking of cable Cables shall be marked with the following: indication of origin; EN reference; voltage rating (Uo); number of conductors and their size;

35、 a code designation according to Annex A; conductor temperature. An example of a complete mark for a sheathed cable is: * EN50382-2 3600V 1x400 OF 150C The marking shall conform to the requirements of EN 50382-1, Clause 5. BS EN 50382-2:2008 7 EN 50382-2:2008 NOTE Other markings (e.g. batch number,

36、year of manufacture) may be added upon agreement between manufacturer and user. 5.2 Colour identification 5.2.1 Insulation The insulation of unsheathed cables shall be black and that of sheathed cables white or neutral unless otherwise agreed between the manufacturer and purchaser. If a colour other

37、 than white or neutral is specified it shall be a colour in accordance with HD 308. The colour shall be clearly identifiable and durable. Durability shall be checked by the test given in EN 50305, 10.1. Conformity with these requirements shall be verified by visual examination. 5.2.2 Sheath The shea

38、th shall be black unless otherwise agreed between the manufacturer and purchaser. 6 Construction of cables 6.1 General The cable shall conform to the applicable general requirements given in EN 50382-1, and to the specific requirements of this part. Conformity with the requirements shall be checked

39、by inspection and by the tests given in Table 7. The cable dimensions shall be as given in Tables 1 to 5 as appropriate to the cable type. 6.2 Conductor For cables rated at 120 C conductors shall be tinned annealed copper, class 5 or class 6, according to EN 60228. For cables rated at 150 C conducto

40、rs shall be plain annealed copper, class 5 or class 6, according to EN 60228. When tested in accordance with EN 10002-1 the minimum average elongation of wires from the conductor shall be 15 %, with a minimum value of 10 % for an individual wire. NOTE It is not necessary to test all individual wires

41、. 5 % of wires or 10 wires, whichever is the fewer, should be selected at random. 6.3 Conductor screening For cables in Tables 3 to 5 it is permitted to use a conductor screen. When used it shall be as given in EN 50382-1, 6.1.6. 6.4 Separator It is permitted to place a non-hygroscopic separator tap

42、e of coloured material between the conductor and insulation if the cable construction does not include a conductor screen. If used, the separator tape shall be easily removable from the conductor. A separator may be included between the insulation and sheath. BS EN 50382-2:2008 EN 50382-2:2008 8 6.5

43、 Insulation system The insulation shall be one or more closely adherent layers of extruded material as defined in EN 50382-1, applied so as to meet the requirements of compound Type EI 111 or EI 112. a) for unsheathed cables: - Type EI 111: extra low temperature resistant, oil resistant; b) for shea

44、thed cables: - Type EI 111: extra low temperature resistant, oil resistant; - Type EI 112: extra low temperature resistant, non oil resistant. The insulation shall be applied to meet the requirements of EN 50382-1, 6.2. The insulation thickness shall conform to the specified value given in Tables 1

45、to 5. 6.6 Sheath Sheath shall be an extruded material as defined in EN 50382-1 applied so as to meet the requirements of compound Type EM 105 or EM 106 or EM 107: - Type EM 105: low temperature resistant, oil resistant; - Type EM 106: extra low temperature resistant, oil resistant; - Type EM 107: ex

46、tra low temperature resistant, oil resistant. If sheathing compounds EM 105 or EM 106 are used, the cable is rated at 120 C. If sheathing compound EM 107 is used, the cable is rated at 150 C. The sheath shall consist of one or more closely adherent layers of the same type. The sheath shall be applie

47、d to meet the requirements of EN 50382-1, 6.4. The sheath thickness shall conform to the specified value given in Tables 2 and 5. 6.7 Textile braid It is permitted to include a textile braid, either within the insulation or at its surface. When a textile braid is included in the construction of a ca

48、ble, it shall consist of material compatible with the operating temperature (for example braid made of glass filaments shall be treated with a suitable substance in order to avoid fraying). When a braid is applied to the surface of the insulation a separator may be included between the insulation an

49、d braid. NOTE A braid may be included in the construction at the request of a customer. BS EN 50382-2:2008 9 EN 50382-2:2008 6.8 Constructional components 6.8.1 Unsheathed cable (Table 1 1,8/3 kV 120 C or 150 C) Cables in Table 1 shall be composed of the following components in the order given: conductor: