1、BRITISH STANDARD BS ISO 15470:2004 Surface chemical analysis X-ray photoelectron spectroscopy Description of selected instrumental performance parameters ICS 71.040.40 ? Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 27 05:45:00 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS ISO 15470:2004 This

2、British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 March 2005 BSI 31 March 2005 ISBN 0 580 45712 5 National foreword This British Standard reproduces verbatim ISO 15470:2004 and implements it as the UK national standard. The UK participation in it

3、s preparation was entrusted to Technical Committee CII/60, Surface chemical analysis, which has the responsibility to: A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement international publications

4、referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary p

5、rovisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretat

6、ion, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the ISO title page, pages ii to v, a blank page, pages 1 to 4, an in

7、side back cover and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. DateComments Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 27 05:45:00 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Refere

8、nce number ISO 15470:2004(E) INTERNATIONAL STANDARD ISO 15470 First edition 2004-05-01 Surface chemical analysis X-ray photoelectron spectroscopy Description of selected instrumental performance parameters Analyse chimique des surfaces Spectroscopie de photolectrons X Description de certains paramtr

9、es relatifs la performance instrumentale BS ISO 15470:2004 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 27 05:45:00 GMT+00:00 2006, Uncontrolled Copy, (c) BSI IS:07451 O4002(E) DPlcsid Fremia ihTs PDF file may ctnoian emdebt dedyfepcaes. In ccaocnadrw eith Aebods licensilop gnic,y this file m

10、airp eb ynted iv roweb detu slahl ton ide ebtlnu deess the typefaces whice era hml era deddebicsnede to i dnanstlaled t noeh computfrep reormign tide ehtin.g In wodlnidaot gnhis file, trapise atpecc tiereht nser ehnopsiiblity fo not infriigngn Aebods licensilop gnic.y ehT ISO tneClar Secrteiraat cac

11、eptl on siibality in this .aera Ai ebods a tredamafo kr Aebod SystemI sncotaropr.de teDails fo teh softwacudorp erts sut deo crtaee this PDF file cna f ebi dnuon tlareneG eh Info leratit evo the file; tP ehDc-Frtaeion marapterew setpo erimizde for irpnti.gn Evyre caer neeb sah taken to sneeru that t

12、he file is suitlbae fosu re yb ISO memdob rebeis. In tlnu ehikletneve y ttah lborp aem leratit gno it is f,dnuo plsaee inform ttneC ehlar Secrteiraat ta the serddaig sleb nevwo. ii BS ISO 15470:2004 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 27 05:45:00 GMT+00:00 2006, Uncontrolled Copy, (c

13、) BSI iii Contents Page Forewordiv Introduction v 1 Scope1 2 Normative references .1 3 Terms and definitions.1 4 Symbols and abbreviations .1 5 Description of selected instrumental performance parameters 1 5.1 Method of analysis1 5.2 Samples1 5.3 System configuration .2 5.4 X-ray source 2 5.5 Spectr

14、ometer intensity performance and energy resolution .2 5.6 Spectrometer energy scale2 5.7 Spectrometer intensity linearity 3 5.8 Spectrometer response function.3 5.9 Imaging and selected area resolution.3 5.10 Charge neutralization .4 5.11 Angle-resolved XPS4 5.12 Vacuum environment4 BS ISO 15470:200

15、4 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 27 05:45:00 GMT+00:00 2006, Uncontrolled Copy, (c) BSI iv Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards

16、is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take pa

17、rt in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to

18、prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility th

19、at some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 15470 was prepared by Technical Committee ISO/TC 201, Surface chemical analysis, Subcommittee SC 7, X-ray photoelectron spectroscopy. BS

20、ISO 15470:2004 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 27 05:45:00 GMT+00:00 2006, Uncontrolled Copy, (c) BSI v Introduction X-ray photoelectron spectrometers are produced by many manufacturers throughout the world. While the basic principle of the XPS analytical method in each instrumen

21、t is the same, the specific designs of the instruments and the way that performance specifications are provided differ widely. As a result, it is often difficult to compare the performance of instruments from one manufacturer with those from another. This International Standard provides a basic list

22、 of items devised to enable all X-ray photoelectron spectrometers to be described in a common manner. This International Standard is not intended to replace the manufacturers specification, which may extend to 30 or more pages. It is intended that, where certain items are defined in that specificati

23、on, there is an agreed and defined meaning to that item. BS ISO 15470:2004 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 27 05:45:00 GMT+00:00 2006, Uncontrolled Copy, (c) BSI blank Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 27 05:45:00 GMT+00:00 2006, Uncontrolled Copy, (c) BSI INTEN

24、RATIONAL TSANDADR IS:07451 O4002(E) Surface chemical analysis X-ray photoelectron spectroscopy Description of selected instrumental performance parameters 1 Scope This International Standard describes the way in which specific aspects of the performance of an X-ray photoelectron spectrometer shall b

25、e described. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 18115, Su

26、rface chemical analysis Vocabulary 3 Terms and definitions For the purposes of this document, the terms and definitions given in ISO 18115 apply. 4 Symbols and abbreviations FWHM full width at half maximum XPS X-ray photoelectron spectroscopy 5 Description of selected instrumental performance parame

27、ters 5.1 Method of analysis A short description of the methods used to obtain information from the sample shall be given, and the availability (as an option) of other analytical techniques in the system under consideration shall be stated. 5.2 Samples The size and shape of samples that may be analys

28、ed with the instrument performing to specification shall be given. If the size or shape is restricted for particular modes of analysis, e.g. angle-resolved measurements, measurements for insulators, etc., this shall be specified. BS ISO 15470:2004 1 Licensed Copy: sheffieldun sheffieldun, na, Mon No

29、v 27 05:45:00 GMT+00:00 2006, Uncontrolled Copy, (c) BSI 5.3 System configuration The designed geometric configuration of significant analytical components of the system and their tolerances shall be described. EXAMPLE Tolerances for angles are often given as 1. 5.4 X-ray source 5.4.1 Anode type The

30、 X-ray anode material shall be specified. The energies and relative intensities of unwanted X-rays shall be specified. 5.4.2 Anode power The maximum X-ray anode power shall be specified by stating the potential between the electron source and the X-ray anode and the maximum filament emission current

31、 to the anode at that potential. These data shall be given for each of the instrumental operating modes specified, and the analytical areas shall be defined, such as: a) large area; b) defined areas for monochromators or c) high-energy resolution or other relevant modes of operation, as appropriate.

32、 5.4.3 Expected anode lifetime The expected lifetime of the X-ray anode under the instrumental operating conditions specified in 5.4.2 shall be stated. This is normally a guaranteed lifetime operation but may, alternatively, be a mean historical lifetime or a graphical description of performance ver

33、sus operating hours at the instrumental operating modes specified in 5.4.2. The type of lifetime shall be specified. 5.5 Spectrometer intensity performance and energy resolution The energy resolution of the system shall be specified by use of the full width at half maximum (FWHM) of the silver Ag 3d

34、5/2 peak from a foil of silver cleaned by ion sputtering or scraping such that the intensities of contaminant peaks are less than 5 % of the Ag 3d5/2. Both peak height intensity and the FWHM of the Ag 3d5/2 peak shall be given for all of the instrumental operating modes specified in 5.4.2. Both the

35、peak height intensity and the FWHM are measured after removal of a straight-line background drawn tangentially at energy points 3 eV above and below the peak position. The energy resolution and intensity data may be provided for any other conditions, as required. It is desirable, but not essential,

36、to specify the performance drift over a period of 10 min and 1 h after any required warm-up time. 5.6 Spectrometer energy scale The repeatability standard deviation of the Cu 2p3/2 peak binding energy for samples re-positioned by the positioning procedure shall be given for all sources specified. Th

37、is procedure should be described in the instrument manual. The binding energy error at the Ag 3d5/2 peak position shall be specified when the instrument has been calibrated using the Cu 2p3/2 and the Au 4f7/2 peaks. The accuracy of the binding energy scale calibration as a function of time shall als

38、o be specified at the energy for the Cu 2p3/2 or Au 4f7/2 peaks. NOTE A method for calibrating the binding energy scale of X-ray photoelectron spectrometers is given in ISO 15472, Surface chemical analysis X-ray photoelectron spectrometers Calibration of energy scales. BS ISO 15470:2004 2 Licensed C

39、opy: sheffieldun sheffieldun, na, Mon Nov 27 05:45:00 GMT+00:00 2006, Uncontrolled Copy, (c) BSI 5.7 Spectrometer intensity linearity The maximum useful count rate, and the maximum count rate for a defined limit of count rate linearity, such as 2 %, shall be stated. 5.8 Spectrometer response functio

40、n Either the spectrometer response function or the energy dependence of that function shall be provided for the relevant instrumental operating modes specified in 5.4.2. The extent to which these functions remain constant with time shall be stated. 5.9 Imaging and selected area resolution 5.9.1 Gene

41、ral Imaging systems and selected area systems are treated equivalently. The measured value of the spatial resolution shall be obtained by one of the methods described in 5.9.2, 5.9.3 or 5.9.4. 5.9.2 Method 1 For imaging systems, a sample shall be analysed which has an isolated feature smaller than 3

42、0 % of the instruments stated spatial resolution. The measured FWHM of a line trace for a photoelectron signal characteristic of that feature defines the spatial resolution. For selected area systems, a sample with a small feature of this kind may be scanned across the analysed area using a micromet

43、er sample stage. The distance for the feature signal to rise from 50 % of the maximum to 100 % and then fall again to 50 % gives the spatial resolution. NOTE 1 If the width of the isolated feature is greater than 30 % of the spatial resolution, the measured spatial resolution will be greater than th

44、e true spatial resolution. NOTE 2 If an instrument has a spatial resolution function that can be represented by a Gaussian function, then the FWHM of such a function corresponds to the distance over which the measured signal changes from 12 % to 88 % of its maximum value. The use of a small sample a

45、llows easy confirmation of the system astigmatism. NOTE 3 The spatial resolution may be energy-dependent. A sample of an appropriately sized bulk dot of copper on gold and gold on copper allows the resolution to be specified at both extremes of the energy scale. 5.9.3 Method 2 For imaging systems, a

46、 sample shall be analysed which is comprised of two materials with their surfaces in the same plane and joined along a common straight edge. A line trace for a photoelectron intensity, characteristic of one of the two materials, measured at 90 to the edge, is used to define spatial resolution. For s

47、elected area systems, the sample may be scanned across the analysed area using a micrometer sample stage by movement at 90 to the above edge. For both systems, the distance for the photoelectron intensity to change from 12 % to 88 % of the difference in the intensities in the plateau regions away fr

48、om the edge defines the spatial resolution in the direction of the scan. NOTE 1 If an instrument has a spatial resolution function that can be represented by a Gaussian function, then the FWHM of such a function corresponds to the distance over which the measured signal changes from 12 % to 88 % of

49、its maximum value. NOTE 2 Close to the limit of resolution, astigmatism may be observed, and so the spatial resolution may need determination in more than one azimuth. NOTE 3 Where the analysis area is defined by an electron-optical method using an image aperture, the resolution is defined by the aperture, and the intensity:distance distribution is equivalent to 64 % of the aperture size. NOTE 4 The spatial resolution may be energy-dependent. A sample comprised of copper and gold a