1、BRITISH STANDARD BS EN 61300-2-44: 2005 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-44: Tests Flexing of the strain relief of fibre optic devices The European Standard EN 61300-2-44:2005 has the status of a British Standard ICS 33.180.20 ?

2、Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 04:32:27 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 61300-2-44:2005 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 19 August 2005 BSI 19 August 2005 ISBN 0 580 46047 9 National for

3、eword This British Standard is the official English language version of EN 61300-2-44:2005. It is identical with IEC 61300-2-44:2004. The UK participation in its preparation was entrusted by Technical Committee GEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre optic interconnecting devices and p

4、assive components, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI

5、 Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for i

6、ts correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK intere

7、sts informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 8, an inside back cover and a back cover. The BSI copyright notice displayed in this docum

8、ent indicates when the document was last issued. Amendments issued since publication Amd. No. DateComments Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 04:32:27 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD EN 61300-2-44 NORME EUROPENNE EUROPISCHE NORM May 2005 CENELEC Europ

9、ean Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels ICS 33.180.20 English version Fibre optic interconnecting devices and passive components Basi

10、c test and measurement procedures Part 2-44: Tests Flexing of the strain relief of fibre optic devices (IEC 61300-2-44:2004) Dispositifs dinterconnexion et composants passifs fibres optiques - Procdures fondamentales dessais et de mesures Partie 2-44: Essais Flexion du serre-cble des dispositifs fib

11、res optiques (CEI 61300-2-44:2004) Lichtwellenleiter Verbindungselemente und passive Bauteile Grundlegende Prf- und Messverfahren Teil 2-44: Prfungen Biegen der Zugentlastung von Lichtwellenleiterbauteilen (IEC 61300-2-44:2004) This European Standard was approved by CENELEC on 2005-04-01. CENELEC me

12、mbers are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on applica

13、tion to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat

14、 has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Po

15、land, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. 2005 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61300-2-44:2005 E Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 04:32:27 GMT+00:00 20

16、06, Uncontrolled Copy, (c) BSI EN 61300-2-44:2005 2 Foreword The text of document 86B/1994/FDIS, future edition 1 of IEC 61300-2-44, prepared by SC 86B, Fibre optic interconnecting devices and passive components, of IEC TC 86, Fibre optics, was submitted to the IEC-CENELEC parallel vote and was appr

17、oved by CENELEC as EN 61300-2-44 on 2005-04-01. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2006-01-01 latest date by which the national standards conflicting with the EN

18、have to be withdrawn (dow) 2008-04-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 61300-2-44:2004 was approved by CENELEC as a European Standard without any modification. _ Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 04:32:27 GMT+00:

19、00 2006, Uncontrolled Copy, (c) BSI 3 E N 61300-2-44:2005 FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS BASIC TEST AND MEASUREMENT PROCEDURES Part 2-44: Tests Flexing of the strain relief of fibre optic devices 1 Scope This part of IEC 61300 details a test to ensure that the captivation

20、 or attachment of a cable to a fibre optic device will withstand a flexing in one plane motion under tensile load of the sort likely to be applied during normal use. This test can be applied to single fibre cables and multiple fibre cables 2 Normative references The following referenced documents ar

21、e indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 61300-1, Fibre optic interconnecting devices and passive components Basic test and

22、 measurement procedures Part 1: General and guidance IEC 61300-3-1, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 3-1: Examinations and measurements Visual examination IEC 61300-3-3, Fibre optic interconnecting devices and passive components Ba

23、sic test and measurement procedures Part 3-3: Examinations and measurements Active monitoring of changes in attenuation and return loss IEC 61300-3-4, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 3-4: Examinations and measurements Attenuation

24、3 General description The device under test is rotated 90o about an axis perpendicular to the axis of the attached cable and in the case of ribbon cable, parallel to the width of the ribbon. This causes a flexing of the strain relief and cable close to the device under test. During the flexing, a te

25、nsile force, but no torque, is applied. If the cable contains ribbon fibre, the flexing motion is applied only across the width of the ribbon. Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 04:32:27 GMT+00:00 2006, Uncontrolled Copy, (c) BSI 4 4 Apparatus 4.1 General The apparatus for testin

26、g and the flexing patterns involved are presented in Figure 1. Figure 1a Overall view of the testing apparatus Fitting S D Weight Tensile force DUT 0,2 m min. Flexing point 90 Minimum bend radius should be bigger 1 2 3 4 IEC 1274/04 1 Figure 1b Flexing patterns 2 3 4 IEC 1275/04 Key 1 Bending counte

27、rclockwise 2 Returning to initial position 3 Bending clockwise 4 Returning to initial position S Optical source D Detector Figure 1 Apparatus for testing 4 EN 61300-2-44:2005 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 04:32:27 GMT+00:00 2006, Uncontrolled Copy, (c) BSI 5 E N 61300-2-44:2

28、005 In the case of duplex cordage, the loads shall not be doubled and the cordage shall be bent in the minor axis direction as shown in Figure 2. Duplex Cordage Load IEC 1276/04 Figure 2 Application of the load in the case of duplex cordage The equipment used is that indicated in 4.2 to 4.5. 4.2 Opt

29、ical source (S) The recommended source shall be in accordance with IEC 61300-3-3 and IEC 61300-3-4 as appropriate. 4.3 Detector (D) The recommended detector shall be in accordance with IEC 61300-3-3 and IEC 61300-3-4 as appropriate. 4.4 Mounting fixture The mounting fixture rigidly holds the fibre o

30、ptic device under test in correct alignment during the test. If the device is a fibre optic connector, an adaptor or a receptacle may be used as a mounting fixture. The fixture shall not distort the device under test. The fixture shall allow the device under test to be connected to monitoring equipm

31、ent. 4.5 Flex test machine or jig A machine or jig that can rotate the DUT 90o from a straight position while applying a load to the fibre or cable. 5 Procedure 5.1 Preparation of specimens Prepare and clean the specimen in accordance with the manufacturers instructions. Visually check (IEC 61300-3-

32、1) that the attachment of the cable to the fibre optic device is not damaged. 5.2 Preconditioning Pre-condition the specimen and all equipment for 2 h at the standard test conditions as defined in IEC 61300-1, unless otherwise specified in the relevant specification. 5.3 Initial measurements Complet

33、e initial examinations and measurements on the specimen as required by the relevant specification. Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 04:32:27 GMT+00:00 2006, Uncontrolled Copy, (c) BSI 6 5.4 Conditioning Install the device under test on the apparatus. Measure the attenuation (IE

34、C 61300-3-4) of the device under test with the flexing arm in a vertical position. Apply the specified tensile load and apply specified number of flexes. Use gentle rotational movements, not exceeding 20 cycles/min. The dwell at each extreme shall not be greater than 5 s. Measure the change in atten

35、uation (IEC 61300-3-3) during test. Stop the flexing with the flexing arm in vertical position. Remove the tensile force. 5.5 Recovery Allow the specimen to remain under standard test conditions for 2 h, as defined in IEC 61300-1, unless otherwise specified in the relevant specification. Clean the s

36、pecimen in accordance with the manufacturers instructions. 5.6 Final measurements Remove the device from the apparatus and make final measurements, as defined by the relevant specification, to ensure that there is no permanent damage to the specimen. The results of the final measurement shall be wit

37、hin the limit established in the relevant specification. Visually check (IEC 61300-3-1) that the attachment of the cable to the fibre optic device is not damaged. 6 Severity Severity is specified by the magnitude of tensile force and the number of cycles to the right and left. Recommended values of

38、the test parameters are given below: a) Passive Components Tensile force: 5 N (1 N for buffer cord) Number of cycles: 30 cycles (90o) Fibre length: 0,2 m 1 m b) Connectors Tensile force: 8,9 N (Std. Connector) 5,9 N (SFF Connector) Number of cycles: 100 cycles (90o) Fibre length: 0,2 m 1 m 6 EN 6130

39、0-2-44:2005 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 04:32:27 GMT+00:00 2006, Uncontrolled Copy, (c) BSI 7 E N 61300-2-44:2005 7 Details to be specified The relevant specification shall specify the following details: magnitude of tensile force; number of flexes; applicable optical fibr

40、e cable (type, length, etc.); initial examination and measurements and performance requirements; permitted change of attenuation during test; final examination and measurements and performance requirements; pass/fail decision criterion; deviations from test procedure. _ Licensed Copy: sheffieldun sh

41、effieldun, na, Mon Nov 13 04:32:27 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 61300-2-44:2005 8 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following referenced documents are indispensable for the application of this d

42、ocument. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE Where an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies.

43、Publication Year Title EN/HD Year IEC 61300-1 - 1) Fibre optic interconnecting devices and passive components - Basic test and measurement procedures Part 1: General and guidance EN 61300-1 2003 2) IEC 61300-3-1 - 1) Part 3-1: Examinations and measurements - Visual examination EN 61300-3-1 1997 2) I

44、EC 61300-3-3 - 1) Part 3-3: Examinations and measurements - Active monitoring of changes in attenuation and return loss EN 61300-3-3 2003 2) IEC 61300-3-4 - 1) Part 3-4: Examinations and measurements - Attenuation EN 61300-3-4 2001 2) 1) Undated reference. 2) Valid edition at date of issue. Licensed

45、 Copy: sheffieldun sheffieldun, na, Mon Nov 13 04:32:27 GMT+00:00 2006, Uncontrolled Copy, (c) BSI blank Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 04:32:27 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 61300-2-44: 2005 BSI 389 Chiswick High Road London W4 4AL BSI British Standards In

46、stitution BSI is the independent national body responsible for preparing British Standards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter. Revisions British Standards are updated by amendment or revision. Users of British Standards

47、 should make sure that they possess the latest amendments or editions. It is the constant aim of BSI to improve the quality of our products and services. We would be grateful if anyone finding an inaccuracy or ambiguity while using this British Standard would inform the Secretary of the technical co

48、mmittee responsible, the identity of which can be found on the inside front cover. Tel: +44 (0)20 8996 9000. Fax: +44 (0)20 8996 7400. BSI offers members an individual updating service called PLUS which ensures that subscribers automatically receive the latest editions of standards. Buying standards

49、 Orders for all BSI, international and foreign standards publications should be addressed to Customer Services. Tel: +44 (0)20 8996 9001. Fax: +44 (0)20 8996 7001. Email: ordersbsi-. Standards are also available from the BSI website at http:/www.bsi-. In response to orders for international standards, it is BSI

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 其他


经营许可证编号:宁ICP备18001539号-1