1、BRITISH STANDARD BS EN 61968-4:2007 Application integration at electric utilities System interfaces for distribution management Part 4: Interfaces for records and asset management The European Standard EN 61968-4:2007 has the status of a British Standard ICS 33.200; 35.200 ? Licensed Copy: London So

2、uth Bank University, London South Bank University, Fri Oct 05 02:36:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI BS EN 61968-4:2007 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 28 September 2007 BSI 2007 ISBN 978 0 580 54263 3 National fo

3、reword This British Standard is the UK implementation of EN 61968-4:2007. It is identical to IEC 61968-4:2007. The UK participation in its preparation was entrusted to Technical Committee PEL/57, Power systems management and associated information exchange. A list of organizations represented on thi

4、s committee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard cannot confer immunity from legal obligations. Amendments issued sin

5、ce publication Amd. No. DateComments Licensed Copy: London South Bank University, London South Bank University, Fri Oct 05 02:36:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD EN 61968-4 NORME EUROPENNE EUROPISCHE NORM August 2007 CENELEC European Committee for Electrotechnical Stan

6、dardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2007 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61968-4:2

7、007 E ICS 33.200 English version Application integration at electric utilities - System interfaces for distribution management - Part 4: Interfaces for records and asset management (IEC 61968-4:2007) Intgration dapplications pour les services lectriques - Systme dinterfaces pour la gestion de la dis

8、tribution - Partie 4: Interfaces pour les enregistrements et la gestion du parc (CEI 61968-4:2007) Integration von Anwendungen in Anlagen der Elektrizittsversorgung - Systemschnittstellen fr Netzfhrung - Teil 4: Schnittstellen fr Berichtswesen und Asset Management (IEC 61968-4:2007) This European St

9、andard was approved by CENELEC on 2007-08-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references conce

10、rning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into

11、its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland

12、, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Licensed Copy: London South Bank University, London South Bank University, Fri Oct 05 02:36:13 GMT+00:00 2007, Uncontrolled Copy,

13、(c) BSI Foreword The text of document 57/880/FDIS, future edition 1 of IEC 61968-4, prepared by IEC TC 57, Power systems management and associated information exchange, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61968-4 on 2007-08-01. The following dates were fi

14、xed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2008-05-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2010-08-01 Annex ZA has been added by CENELEC. _

15、 Endorsement notice The text of the International Standard IEC 61968-4:2007 was approved by CENELEC as a European Standard without any modification. _ 2 EN 61968-4:2007 Licensed Copy: London South Bank University, London South Bank University, Fri Oct 05 02:36:13 GMT+00:00 2007, Uncontrolled Copy, (

16、c) BSI CONTENTS INTRODUCTION.4 1 Scope.5 2 Normative references .5 3 Reference and information models .5 3.1 General.5 3.2 Interface reference model5 3.3 Records and asset management functions and components5 3.4 Static information model6 4 Records and Asset message types.6 4.1 Summary.6 4.2 Network

17、 Data Set message type6 4.2.1 Message content .6 4.2.2 Message format.6 4.3 Change Set message type.23 4.3.1 Message content .23 4.3.2 Message format.23 4.4 Presentation message type .23 4.4.1 Message content .23 4.4.2 Message format.23 4.5 Asset List message type28 4.5.1 Message content .28 4.5.2 M

18、essage format.28 4.6 Asset Catalogue message type .35 4.6.1 Message content .35 4.6.2 Message format.35 4.7 Type Asset Catalogue message type.41 4.7.1 Message content .41 4.7.2 Message format.41 Annex A (informative) Use of the Geography Markup Language (GML).50 Figure 1 Network Data Set message for

19、mat .7 Figure 2 Change Set message format 23 Figure 3 Presentations message format .24 Figure 4 Asset List message format .29 Figure 5 Asset Catalogue message format.36 Figure 6 Type Asset Catalogue message format 42 Table 1 Document overview for IEC 61968-4 .4 EN 61968-4:2007 3 Annex ZA (normative)

20、 Normative references to international publications with their corresponding European publications.51 Licensed Copy: London South Bank University, London South Bank University, Fri Oct 05 02:36:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI INTRODUCTION The IEC 61968 series of standards is intended t

21、o facilitate inter-application integration as opposed to intra-application integration. Intra-application integration is aimed at programs in the same application system, usually communicating with each other using middleware that is embedded in their underlying runtime environment, and tends to be

22、optimized for close, real- time, synchronous connections and interactive request/reply or conversation communication models. IEC 61968, by contrast, is intended to support the inter-application integration of a utility enterprise that needs to connect disparate applications that are already built or

23、 new (legacy or purchased applications), each supported by dissimilar runtime environments. Therefore, these interface standards are relevant to loosely coupled applications with more heterogeneity in languages, operating systems, protocols and management tools. This series of standards is intended

24、to support applications that need to exchange data every few seconds, minutes, or hours rather than waiting for a nightly batch run. This series of standards, which are intended to be implemented with middleware services that exchange messages among applications, will complement, not replace utility

25、 data warehouses, database gateways, and operational stores. As used in the IEC 61968 series, a DMS consists of various distributed application components for the utility to manage electrical distribution networks. These capabilities include monitoring and control of equipment for power delivery, ma

26、nagement processes to ensure system reliability, voltage management, demand-side management, outage management, work management, automated mapping and facilities management. Standards interfaces are defined for each class of applications identified in the Interface Reference Model (IRM), which is de

27、scribed in IEC 61968-1. This Part of IEC 61968 contains the Clauses shown in Table 1. Table 1 Document overview for IEC 61968-4 Clause Title Purpose 1 Scope The scope and purpose of the document are described. 2 Normative references Documents that contain provisions which, through reference in this

28、text, constitute provisions of this International Standard. 3 Reference and information models Description of the relevant parts of the interface reference model, static information model and message type naming convention. 4 Records and asset management message types Message types related to the ex

29、change of information for network data sets, assets, and asset catalogues. EN 61968-4:2007 4 Licensed Copy: London South Bank University, London South Bank University, Fri Oct 05 02:36:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI APPLICATION INTEGRATION AT ELECTRIC UTILITIES SYSTEM INTERFACES FOR D

30、ISTRIBUTION MANAGEMENT Part 4: Interfaces for records and asset management 1 Scope This Part of IEC 61968 specifies the information content of a set of message types that can be used to support many of the business functions related to records and asset management. Typical uses of the message types

31、defined in this Part of IEC 61968 include network extension planning, copying feeder or other network data between systems, network or diagram edits and asset inspection. Message types defined in other Parts of IEC 61968 may also be relevant to these use cases. 2 Normative references The following r

32、eferenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 61968-1, Application integration at electric utilities Syste

33、m interfaces for distribution management Part 1: Interface architecture and general requirements IEC 61968-3, Application integration at electric utilities - System interfaces for distribution management - Part 3: Interface for network operations 3 Reference and information models 3.1 General The me

34、ssage types defined in IEC 61968-4 are based on a logical partitioning of the DMS business functions and components called the IEC 61968-1 Interface reference model. As described, in IEC 61968-1, the contents of the message types are based on a static information model to ensure consistency of field

35、 names and data types. Each message type is defined as a set of fields copied from the information model classes. The message types defined in this standard are intended to satisfy a majority of typical applications. In some particular project implementations, it may be desirable to modify the set o

36、f fields using a methodology such as that described in IEC 61968-1. 3.2 Interface reference model It is not the intention of the IEC 61968 series to define the applications and systems that vendors should produce. It is expected that a concrete (physical) application will provide the functionality o

37、f one or more abstract (logical) components as listed in this standard. These abstract components are grouped by the business functions of the IEC 61968-1 interface reference model. 3.3 Records and asset management functions and components The Records and Asset Management part of the IEC 61968-1 Int

38、erface reference model shows those functions and typical components that are applicable to the message types defined in IEC 61968-4. EN 61968-4:2007 5 Licensed Copy: London South Bank University, London South Bank University, Fri Oct 05 02:36:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI For the mes

39、sage types defined in IEC 61968-4, it is expected that the typical abstract components listed below will be producers of information. Typical consumers of the information are the other components as listed in IEC 61968-1. 3.4 Static information model The information model relevant to records and ass

40、et management consists of classes that provide a template for the attributes for each message. The classes are defined in detail in IEC 61970-301 or in future document IEC 61968-11. 4 Records and Asset message types 4.1 Summary The records and asset message types describe information for the followi

41、ng types of document: network data set, change set, presentation, asset list, asset catalogue, type asset catalogue. For all message types shown in IEC 61968-4, elements that correspond with CIM classes contain all native and inherited attributes of that class. Unless explicitly shown otherwise, all

42、 message type associations are simple associations. 4.2 Network Data Set message type 4.2.1 Message content A NetworkDataSet message can contain data for any part of a distribution network typically selected for operational or extension planning studies. The message contents could be part of a feede

43、r, a single feeder or more than one feeder. The data could be either the As built network or a proposed network selected for analysis. A NetworkDataSet message may contain references to other Documents containing static reference data such as TypeAssetCatalogue or AssetCatalogue. It may also contain

44、 references to Assets performing the roles of the associated types of PowerSystemResources. The same is true for other “leaf node” elements such as Organisations, Locations, and Measurements. In these cases, only the identifier for the referenced data is to be included in this message type. The actu

45、al data for referenced elements are provided through other types of messages (e.g.,TypeAssetCatalogue, AssetCatalogue, AssetList, Measurements). The basic structure is a hierarchy as shown in Figure 1. The initial dynamic state of the network including switch positions is defined as a set of Measure

46、mentValues. These values can be updated using the ShowMeasurementList message defined in IEC 61968-3. 4.2.2 Message format Created NetworkDataSet, changed NetworkDataSet, show NetworkDataSet and deleted NetworkDataSet have the same message formats as shown in Figure 1. EN 61968-4:2007 6 Licensed Cop

47、y: London South Bank University, London South Bank University, Fri Oct 05 02:36:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI Figure 1 Network Data Set message format (continued on next page) IEC 1108/07 EN 61968-4:2007 7 Licensed Copy: London South Bank University, London South Bank University, Fri

48、 Oct 05 02:36:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI Figure 1 (continued) IEC 1109/07 EN 61968-4:2007 8 Licensed Copy: London South Bank University, London South Bank University, Fri Oct 05 02:36:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI Figure 1 (continued) IEC 1110/07 EN 61968-4:2007 9

49、Licensed Copy: London South Bank University, London South Bank University, Fri Oct 05 02:36:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI Figure 1 (continued) IEC 1111/07 EN 61968-4:2007 10 Licensed Copy: London South Bank University, London South Bank University, Fri Oct 05 02:36:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI Figure 1 (continued) IEC 1112/07 EN 61968-4:2007 11 L

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 其他


经营许可证编号:宁ICP备18001539号-1