BS-EN-50505-2008.pdf

上传人:小小飞 文档编号:3747575 上传时间:2019-09-22 格式:PDF 页数:76 大小:2.28MB
返回 下载 相关 举报
BS-EN-50505-2008.pdf_第1页
第1页 / 共76页
BS-EN-50505-2008.pdf_第2页
第2页 / 共76页
BS-EN-50505-2008.pdf_第3页
第3页 / 共76页
BS-EN-50505-2008.pdf_第4页
第4页 / 共76页
BS-EN-50505-2008.pdf_第5页
第5页 / 共76页
亲,该文档总共76页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《BS-EN-50505-2008.pdf》由会员分享,可在线阅读,更多相关《BS-EN-50505-2008.pdf(76页珍藏版)》请在三一文库上搜索。

1、BRITISH STANDARD BS EN 50505:2008 Basic standard for the evaluation of human exposure to electromagnetic fields from equipment for resistance welding and allied processes ICS 13.280; 25.160.30 ? Copyright British Standards Institution Provided by IHS under license with BSI - Uncontrolled Copy Licens

2、ee=Boeing Co/5910770001 Not for Resale, 08/14/2008 21:04:14 MDTNo reproduction or networking permitted without license from IHS -,-,- BS EN 50505:2008 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 June 2008 BSI 2008 ISBN 978 0 580 57717

3、8 National foreword This British Standard is the UK implementation of EN 50505:2008. The UK participation in its preparation was entrusted to Technical Committee WEE/29, Resistance welding. A list of organizations represented on this committee can be obtained on request to its secretary. This public

4、ation does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard cannot confer immunity from legal obligations. Amendments/corrigenda issued since publication DateComments Copyright British Standards I

5、nstitution Provided by IHS under license with BSI - Uncontrolled Copy Licensee=Boeing Co/5910770001 Not for Resale, 08/14/2008 21:04:14 MDTNo reproduction or networking permitted without license from IHS -,-,- EUROPEAN STANDARD EN 50505 NORME EUROPENNE EUROPISCHE NORM April 2008 CENELEC European Com

6、mittee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELE

7、C members. Ref. No. EN 50505:2008 E ICS 25.160.30 English version Basic standard for the evaluation of human exposure to electromagnetic fields from equipment for resistance welding and allied processes Norme de base destine lvaluation de lexposition humaine aux champs lectromagntiques manant du mat

8、riel de soudage par rsistance et des techniques connexes Grundnorm fr die Bewertung der menschlichen Exposition gegenber elektromagnetischen Feldern von Einrichtungen zum Widerstands- schweien und fr verwandte Verfahren This European Standard was approved by CENELEC on 2008-03-01. CENELEC members ar

9、e bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to

10、the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the

11、 same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands,

12、Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Copyright British Standards Institution Provided by IHS under license with BSI - Uncontrolled Copy Licensee=Boeing Co/5910770001 Not for Resale, 08/14/2008 21:04:14 MDTNo reproduction or network

13、ing permitted without license from IHS -,-,- EN 50505:2008 - 2 - Foreword This European Standard was prepared by the Technical Committee CENELEC TC 26B, Electric resistance welding. The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50505 on 2008-03-01. The foll

14、owing dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2009-03-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2011-03-01 This European Stan

15、dard shall be read in conjunction with EN 50445. This European Standard has been prepared under mandates M/305 and M/351 given to CENELEC by the European Commission and the European Free Trade Association. _ BS EN 50505:2008 Copyright British Standards Institution Provided by IHS under license with

16、BSI - Uncontrolled Copy Licensee=Boeing Co/5910770001 Not for Resale, 08/14/2008 21:04:14 MDTNo reproduction or networking permitted without license from IHS -,-,- - 3 - EN 50505:2008 Contents 1 Scope . 5 2 Normative references . 6 3 Definitions . 6 3.1 General . 6 3.2 Specific for resistance weldin

17、g and similar applications 8 4 Physical quantities, units and constants .10 4.1 Quantities and units 10 4.2 Constants10 5 Assessment procedures 10 5.1 General .10 5.2 Resistance welding equipment EMF emission description 10 5.3 Assessment conditions .11 5.4 Averaging11 5.5 Pulsed or non-sinusoidal w

18、elding current .12 5.6 Conductivity of living tissue 18 5.7 Frequency range limitations .18 5.8 Application of assessment procedures .19 5.9 Measurements 21 5.10 Analytical calculations 23 5.11 Numerical calculations 28 6 Uncertainty of assessment 30 6.1 Including uncertainty .30 6.2 Evaluation of u

19、ncertainties .31 6.3 Reasonable overall uncertainties .31 6.4 Examples of typical uncertainties .32 7 Assessment report .32 7.1 General principles .32 7.2 Items to be recorded in the assessment report 33 Annex A (normative) Assessment parameters 34 Annex B (informative) Examples for exposure assessm

20、ent 46 Annex C (informative) Numerical simulation using anatomical body models .59 Annex D (normative) Determination of coupling factor 63 Annex E (informative) Summation weighting and transfer function examples 65 Annex F (informative) Example for an uncertainty budget .70 Bibliography 71 Figures F

21、igure 1 Example for parameters of a welding current sequence . 12 Figure 2 Average electrical conductivities for homogeneous body modelling from 10 Hz to 10 MHz 18 Figure 3 Double parallel conductor model 25 Figure 4 Rectangular conductor model 26 Figure A.1 Points of investigation for stationary we

22、lding equipment 35 Figure A.2 Point of investigation for portable hand-held welding equipment . 36 BS EN 50505:2008 Copyright British Standards Institution Provided by IHS under license with BSI - Uncontrolled Copy Licensee=Boeing Co/5910770001 Not for Resale, 08/14/2008 21:04:14 MDTNo reproduction

23、or networking permitted without license from IHS -,-,- EN 50505:2008 - 4 - Figure A.3 Point of investigation for suspended welding equipment . 37 Figure A.4 Point of investigation for a single side welding tool 38 Figure A.5 Point of investigation for a double side welding tool . 38 Figure A.6 Simul

24、ation geometry for stationary equipment . 40 Figure A.7 Simulation geometry A 41 Figure A.8 Simulation geometry B 42 Figure A.9 Simulation geometry C . 43 Figure A.10 Simulation geometry for single side welding tool equipment 44 Figure A.11 3D models dimensions for spheroid and cylindrical models .

25、45 Figure B.1 Flux density waveform and r.m.s. spectral components for summation. 48 Figure B.2 Summation of ratios Bi / BL,i including phases in the time domain . 49 Figure B.3 Flux density waveform and r.m.s. spectral components for summation. 50 Figure B.4 Current density distribution on disk dia

26、meter for f = 50 Hz. 51 Figure B.5 Summation of ratios Ji / JL,i including phases in the time domain . 52 Figure B.6 Welding current and measured field waveform 53 Figure B.7 Obtained flux density waveform and r.m.s. spectral components 55 Figure B.8 Summation of ratios Ji / JL,i including phases in

27、 the time domain . 56 Figure B.9 J spectral components summation including phases in the time domain. 56 Figure B.10 Measurement sensor position. 57 Figure E.1 Peak reference level transfer function and tabulated values 66 Figure E.2 B summation weighting function and phase tabulated values 67 Figur

28、e E.3 Peak basic restriction transfer function and tabulated values 68 Figure E.4 J summation weighting function and phase tabulated values 69 Tables Table 1 Permissible assessment procedures for resistance welding equipment 19 Table 2 Reasonable expanded assessment uncertainties . 31 Table B.1 Flux

29、 density spectral components 47 Table B.2 Flux density spectral components 48 Table B.3 Flux density spectral components 49 Table B.4 Flux density spectral components 50 Table B.5 Result of flux density spectral components summation . 50 Table B.6 Result of current density spectral components summat

30、ion . 51 Table B.7 Result of spectral components summation 54 Table B.8 Flux density and induced current spectral components 55 Table C.1 Electrical conductivity of tissue types 61 Table F.1 Example uncertainty budget for broadband field measurement 70 BS EN 50505:2008 Copyright British Standards In

31、stitution Provided by IHS under license with BSI - Uncontrolled Copy Licensee=Boeing Co/5910770001 Not for Resale, 08/14/2008 21:04:14 MDTNo reproduction or networking permitted without license from IHS -,-,- - 5 - EN 50505:2008 1 Scope This European Standard applies to equipment for resistance weld

32、ing and allied processes designed for use in industrial or domestic environments. NOTE 1 Typical allied processes are resistance hard and soft soldering or resistance heating achieved by means comparable to resistance welding equipment. This European Standard establishes a suitable evaluation method

33、 for determining the electromagnetic fields in the space around the equipment and defines standardized operating conditions and measuring distances. It provides a method to show conformity with guidelines or requirements concerning human exposure to electromagnetic fields. The Directive 2006/95/EC o

34、f the European Parliament and the Council 1, Article 2, stipulates that the Member States take all appropriate measures to ensure that electrical equipment may be placed on the market only if, having been constructed in accordance with good engineering practice in safety matters in force in the Comm

35、unity, it does not endanger the safety of persons, domestic animals or property when properly installed and maintained and used in applications for which is was made. The principal elements of those safety objectives are listed in Annex I Clause 2.b. This standard may be used in conjunction with EN

36、50445 for demonstration of conformity to the Council Directive with reference to human exposure to electromagnetic fields (EMF). There are additional requirements covered by Article 2 and Annex I Clause 2.b, which are not included in this document. The Council Recommendation 1999/519/EC 2 provides B

37、asic Restrictions and Derived reference levels for exposure of the general public. This standard may be used for demonstration of resistance welding equipment conformity to the Council Recommendation on this basis, but there may be additional specific national or international requirements which are

38、 not included. The ICNIRP Guidelines 3, on limits of exposure to static magnetic fields as well as for limiting exposure in time varying electric, magnetic and electromagnetic fields, provide Basic restrictions and Derived reference levels for both occupational and general exposure. This standard ma

39、y be used for demonstration of equipment conformity to ICNIRP Guidelines on this basis, but there may be additional national or international requirements which are not included. It is also possible to use this document as a basis to demonstrate conformity of resistance welding equipment to other na

40、tional and international guidelines or requirements with regard to human exposure from EMF, for example Council Directive 2004/40/EC 4 on the minimum health and safety requirements regarding the exposure of workers to the risk arising from physical agents (electromagnetic fields), or the requirement

41、s of the Directive 98/37/EC 5. In these cases, other restrictions and levels than those referenced above may be used. Other standards may apply to equipment covered by this standard. In particular this standard can not be used to demonstrate electromagnetic compatibility with other equipment; nor do

42、es it specify any product safety requirements other than those specifically related to human exposure to electromagnetic fields. The frequency range covered is 0 Hz to 300 GHz. NOTE 2 Procedures to demonstrate conformity are not specified for the whole frequency range. BS EN 50505:2008 Copyright Bri

43、tish Standards Institution Provided by IHS under license with BSI - Uncontrolled Copy Licensee=Boeing Co/5910770001 Not for Resale, 08/14/2008 21:04:14 MDTNo reproduction or networking permitted without license from IHS -,-,- EN 50505:2008 - 6 - 2 Normative references The following referenced docume

44、nts are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 50392 2004 Generic standard to demonstrate the compliance of electronic and e

45、lectrical apparatus with the basic restrictions related to human exposure to electromagnetic fields (0 Hz 300 GHz) EN 50445 2008 Product family standard to demonstrate compliance of equipment for resistance welding, arc welding and allied processes with the basic restrictions related to human exposu

46、re to electromagnetic fields (0 Hz 300 GHz) EN 61566 1997 Measurement of exposure to radio-frequency electromagnetic fields Field strength in the frequency range 100 kHz to 1 GHz (IEC 61566:1997) EN 62226-1 2005 Exposure to electric or magnetic fields in the low and intermediate frequency range Meth

47、ods for calculating the current density and internal electric field induced in the human body Part 1: General (IEC 62226-1:2004) EN 62226-2-1 2005 Exposure to electric or magnetic fields in the low and intermediate frequency range Methods for calculating the current density and internal electric fie

48、ld induced in the human body Part 2-1: Exposure to magnetic fields 2D models (IEC 62226-2-1:2004) EN ISO/IEC 17025 2005 General requirements for the competence of testing and calibration laboratories (ISO/IEC 17025:2005) IEC 61786 1998 Measurement of low-frequency magnetic and electric fields with regard to exposure of human beings Special requirements f