1、Symbol and labels for moisture-sensitive devices 3 8 % / , 2000, IEC JEDEC Publication No. 113-B Page 4 4 Symbols and Labels (contd) 4.3.3 Level 6 Level 6 devices must be identified as “EXTREMELY MOISTURE SENSITIVE”. See Figure 5. This label is required on the moisture barrier bag and/or the lowest

2、level shipping container. The label must specify the peak package body temperature at which the device was classified. If the required information is not provided on the caution label then it must be on the adjacent bar code label. Level 6, as defined by J-STD-020, does not require that devices be s

3、hipped in a moisture-barrier bag with desiccant, etc. (dry-pack), since these devices require baking by the end user before use. However, moisture-barrier bags have become a “symbol” for moisture-sensitive devices and therefore are recommended to be used with level 6 device shipments. It is also rec

4、ommended that these bags be sealed even though desiccant and humidity indicator cards (HIC) may not be inside the bags. 6 CAUTION EXTREMELY MOISTURE SENSITIVE LEVEL 1. Must be baked before mounting for 48 hours. at 125 5 C in high-temperature device containers Note: Level and body temperature define

5、d by IPC/JEDEC J-STD-020 2. After baking devices must be mounted within 6 hours at factory conditions of 30 C/60% RH Peak package body temperature: C If Blank, see adjacent bar code label Note: If device containers cannot be subjected to high temperature or shorter bake times are desired, reference

6、IPC/JEDEC J-STD-033 for bake procedure Figure 5 Moisture-sensitive caution label for level 6 4.3.4Label size Labels are recommended to be a minimum of 3 inches (76.2 millimeters) by 3 inches (76.2 millimeters) square. Copyright 1999, JEDEC; 2000, IEC JEDEC Publication No. 113-B Page 5 4.3.5Label col

7、ors The ID and caution labels shall be contrasting colors. These labels shall be legible to normal vision at a distance of three feet. Monochromatic reproduction in any color that contrasts with the background may be used. Where the choice of color is arbitrary, it is suggested that: 1) The ID label

8、 background be blue (Pantone #297C) with a black symbol and letters. 2) The caution label background be white with a blue (Process blue) symbol and letters. Wherever possible the color red should be avoided as red suggests a personal hazard. Copyright 1999, JEDEC; 2000, IEC ICS 31.080.01 Typeset and printed by the IEC Central Office GENEVA, SWITZERLAND CODE PRIX C For price, see current catalogue ISBN 2-8318-5272-2 ?85:53?