《IEEE-1580-ERTA-2008.pdf》由会员分享,可在线阅读,更多相关《IEEE-1580-ERTA-2008.pdf(3页珍藏版)》请在三一文库上搜索。
1、27 March 2008SH94944 IEEE Std 1580-2001 Errata to IEEE Recommended Practice for Marine Cable for Use on Shipboard and Fixed or Floating Platforms Sponsor International Marine Industry Committee of the IEEE Industry Applications Society Correction Sheet Issued 27 March 2008 Copyright 2008 by the Inst
2、itute of Electrical and Electronics Engineers, Inc. All rights reserved. Published 2008. Printed in the United States of America. This correction sheet may be freely reproduced and distributed in order to maintain the utility and currency of the underlying Standard. This correction sheet may not be
3、sold, licensed or otherwise distributed for any commercial purposes whatsoever. The content of this correction sheet may not be modified. Contents of this correction sheet have been incorporated into the second printing of IEEE Std 1580-2001. Correction Sheet to IEEE Std 1580-2001 SH9494427 March 20
4、08 The metric value of 12.5 N/mm2 should read as 12.4 N/mm2 in the row of the following tables: Page 29 Page 31 Page 35 and Page 69 Test potentials (V) should read as Test potentials (kV) as follows: Page 37 (Table 19) Table 19High-voltage ac test potentials; type E, S, X, T, T/N, LSE, LSX and P cab
5、les Table 12Insulation, electrical, and physical requirements; Types E, X, S, T, and T/N Tensile strength, N/mm2, min 8.24.812.412.45.513.813.8 Table 14Insulation, electrical, and physical requirements for crosslinked polyolefin insulation (type P), voltage rating 02000 V Tensile strength, N/mm2, mi
6、n12.4 Table 16Jacket properties; type T, CP, N, and CPE Tensile strength, N/mm2, min10.312.412.412.4 Table C.3Low-smoke, halogen-free jacket properties: types L (XLPO) and TPO (TPPO) N/mm2Ibf/in2 12.41800 Test potentials (kV) 0300 V 301600/ 1000 V 1001 2000 V 20015000 V Correction Sheet to IEEE Std 1580-2001 SH9494427 March 2008 Page 39 Table 21 Note A should read as follows: aCalculated from the formula M = C (t 15.6) in which C is determined as described in 5.17.4.2.6 and t is the temperature of the cable in C.