1、BRITISH STANDARD BS 5489-5: 1992 Road lighting Part 5: Code of practice for lighting for grade-separated junctions Licensed Copy: sheffieldun sheffieldun, na, Mon Dec 04 12:35:55 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 5489-5:1992 This British Standard, having been prepared under the direction

2、 of the Electrical Illumination Standards Policy Committee, was published under the authority of the Standards Board and comes into effect on 15 August 1992 BSI 12-1998 First published as CP 1004-5 March 1973 Amended as BS 5489-5 December 1977 Second edition January 1990 Third edition August 1992 Th

3、e following BSI references relate to the work on this standard: Committee reference LGL 23 Draft announced in BSI News March 1992 ISBN 0 580 20920 2 Committees responsible for this British Standard The preparation of this British Standard was entrusted by the Electrical Illumination Standards Policy

4、 Committee (LGL/-) to Technical Committee LGL/23, upon which the following bodies were represented: Automobile Association British Lighting Association for the Preparation of Standards (Britlaps) British Precast Concrete Federation Ltd. Chartered Institution of Building Services Engineers Council fo

5、r the Protection of Rural England County Surveyors Society Department of Transport Institution of Civil Engineering Surveyors Institution of Civil Engineers Institution of Electrical Engineers Institution of Lighting Engineers Institution of Mechanical Engineers Lighting industry Federation Ltd. Roy

6、al Fine Art Commission Scottish Office (Building Directorate) Amendments issued since publication Amd. No.DateComments Licensed Copy: sheffieldun sheffieldun, na, Mon Dec 04 12:35:55 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 5489-5:1992 BSI 12-1998i Contents Page Committees responsibleInside fro

7、nt cover Forewordii 1Scope1 2Definitions1 3Need for lighting1 4General principles1 5Aesthetic considerations1 6Lighting by systems designed in accordance with the recommendations in BS 5489-2, BS 5489-3 and BS 5489-42 7Lighting by high-mast techniques3 8Maintenance4 Figure 1 Grade-separated junction

8、 full lighting system in accordance with BS 5489-2 and BS 5489-45 Figure 2 Grade-separated junction partial lighting system in accordance with BS 5489-2 and BS 5489-46 Figure 3 Typical high-mast lighting techniques for a grade-separated junction7 Figure 4 High-mast light distribution showing isolux

9、contours8 Figure 5 Isolux contours from a combination of luminaires to produce a high-mast light distribution9 Publication(s) referred toInside back cover Licensed Copy: sheffieldun sheffieldun, na, Mon Dec 04 12:35:55 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 5489-5:1992 ii BSI 12-1998 Foreword

10、 This Part of BS 5489 has been prepared under the direction of the Electrical Illumination Standards Policy Committee and is a new edition of BS 5489-5:1989 which is withdrawn. The 1989 edition reviewed the special problems of lighting grade-separated junctions and enhancements were made to the proc

11、ess of selecting the most appropriate type of installation. Recommendations related to the use of lighting by systems given in BS 5489-2 and BS 5489-3 and to high-mast techniques and reflected the need to provide good levels of illumination. This edition incorporates editorial improvements but it do

12、es not reflect a full review or revision of the standard, which will be undertaken in due course. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard do

13、es not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 10, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated.

14、This will be indicated in the amendment table on the inside front cover. Licensed Copy: sheffieldun sheffieldun, na, Mon Dec 04 12:35:55 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 5489-5:1992 BSI 12-19981 1 Scope This Part of BS 5489 gives recommendations for the lighting of grade-separated junct

15、ions and provides guidance on the factors which may influence a choice between, or a combination of, lighting systems in accordance with BS 5489-2, or high-mast lighting. Guidance on the lighting of roundabouts, bridges, elevated roads, underpasses and subsidiary roads which may be associated with g

16、rade-separated junctions is given in BS 5489-3, BS 5489-4, BS 5489-6, BS 5489-7 and BS 5489-10. NOTEThe titles of the publications referred to in this standard are listed on the inside back cover. 2 Definitions For the purposes of this Part of BS 5489, the definitions given in BS 5489-1, BS 6100-2.4

17、.1 and BS 5225-1 apply, together with the following. 2.1 grade-separated junction a road junction at which at least one road passes over another 2.2 high-mast lighting a system of lighting for large areas in which masts giving a mounting height of 18 m, or more, carry clusters of high-output luminai

18、res 3 Need for lighting There are three main characteristics of grade-separated junctions where the provision of lighting should be considered: a) where some or all of the approach roads concerned are lit; b) where the junction design involves abrupt changes of horizontal or vertical curvature; c) w

19、here the junction is so complicated that lighting is essential for safety and night-time visibility. 4 General principles 4.1 Extent of lighting Consideration should be given to the number of roads present and their relative dispositions. This may indicate the need for either lighting of individual

20、roads or an integrated lighting system covering large areas. 4.2 Recommended values Recommendations on values of luminance and uniformity ratios and limits of threshold increment (TI) are given in BS 5489-2, BS 5489-4, BS 5489-6 and BS 5489-7. 4.3 Deviations from luminance-based assessment A luminan

21、ce-based design should be applied as in BS 5489-2, where it can be calculated. Assessment of this design should be based on a limited number of prescribed observer positions. Other areas, such as sharp bends, junctions and changes in gradient, should be designed on an illuminance basis. Values of av

22、erage illuminance in these other areas should be not less than those calculated or measured on the adjacent roads. The ratio of minimum illuminance to average illuminance should be not less than 0.5 for main carriageways and not less than 0.4 for slip roads, over any 60 m length of road. 4.4 Route m

23、erge points At some grade-separated junctions, the roads associated with the junction may be widely spread. Lighting should be provided to cover all points where these roads merge with each other so that drivers are able to determine their intended route as clearly as possible. The luminance or illu

24、minance of these merge areas should be not less than those values of lighting for the approach roads. 4.5 Route guidance Whilst lighting can show the various routes available, it does not usually provide the information necessary to assist in the choice of route. Such information should normally be

25、furnished by traffic signs. The road lighting and signing requirements should be considered jointly so that a coordinated layout is achieved without impairing daytime sight lines. 5 Aesthetic considerations The important points to be considered in the design of lighting for grade-separated junctions

26、 are: a) the daytime appearance of road lighting schemes as described in BS 5489-1; b) that the column, bracket projections, luminaire, and, for high-mast lighting, the mast, headframe and luminaire assembly, should be of good integrated design; c) that the scheme as a whole should be compatible wit

27、h its setting by day and night. At the approaches to a junction, it is desirable to avoid the appearance of a confusing array of columns or luminaires. Also, it is desirable in the design of complex layouts that involve both horizontal and vertical curves and changes of radius, to avoid using equipm

28、ent with complex outlines. Where bracket projections are used, simple straight designs with a uniform uplift are to be preferred to avoid the tangled-web effect of curved bracket projections of varying projections and alignment. Licensed Copy: sheffieldun sheffieldun, na, Mon Dec 04 12:35:55 GMT+00:

29、00 2006, Uncontrolled Copy, (c) BSI BS 5489-5:1992 2 BSI 12-1998 6 Lighting by systems designed in accordance with the recommendations in BS 5489-2, BS 5489-3 and BS 5489-4 6.1 General Where a site involves a single grade-separated junction (e.g. of two-level, four-ways with a roundabout layout abov

30、e or below the major road), and particularly in rural areas, it is normally preferable to light the junction using the methods defined in Parts 2, 3 and 4 of this standard. Figure 1 illustrates a typical full lighting system designed to the requirements of Parts 2 and 4 of this standard. If only the

31、 minor road is to have lighting, a partial lighting system may have to be designed to avoid throwing light onto the carriageway of the major road (see Figure 2). 6.2 Design characteristics 6.2.1 General The factors governing the application of road lighting to grade-separated junctions are in genera

32、l those applicable to the use of methods in other road situations as set out in Parts 2, 3 and 4 of this standard. Design of layouts should, however, avoid a confusion of light sources at the different levels and angles of approach. 6.2.2 Light distribution The degree of glare is affected by the nat

33、ure of the background, variations in gradient and the number, positions and orientation of luminaires in the field of view. Because of the above factors, low threshold increment (LTI) distributions may be appropriate. 6.2.3 Design considerations Priority should be given to the needs of any major roa

34、d within the junction. In many cases, this will be a dual carriageway road and can most easily be defined throughout by lighting from columns mounted in the central reserve. If centrally mounted safety fences are being provided as safety measures, these, as a secondary function, can give protection

35、to the columns. If safety fences are not being provided, the need for local protection and suitable siting of the columns should be considered (see also 7.2.5). 6.2.4 Slip roads Slip roads usually join the main carriageway by tapering acceleration or deceleration lanes. Where the main carriageway is

36、 lit, single-sided lighting, which can usually be of a lesser mounting height and with lower output luminaires, should commence from a point on a taper along the length of each slip road to give delineation of the slip roads and to reinforce the lighting in the areas where the road widens. 6.2.5 Gla

37、re For junctions where a roundabout or other road layout is above or below the major road, care should be exercised to avoid undue glare from light sources on the lower carriageway which might affect the users of the upper road. Correct siting of columns and the use of columns of reduced height in t

38、he immediate vicinity of the upper road coupled with luminaires of LTI classification afford a means of controlling the problem. Further guidance on the lighting of roundabouts is given in Part 4 of this standard. 6.2.6 Engineering considerations 6.2.6.1 Site works Consideration should be given to t

39、he lighting at an early stage in the design of the junction so that fixings for columns and cable ducting may be allowed for and incorporated in the structures. It is equally important that longitudinal and transverse ducting and draw-in chambers are provided for any future lighting. 6.2.6.2 Structu

40、ral constraints Much of the lighting in complex grade-separated junctions may be on viaducts and bridges and guidance on structural considerations and daytime appearance, etc. is contained in BS 5489-6. It may be difficult to relate lighting columns to structural elements, such as supports, and the

41、initial spacings arrived at by lighting design calculations may have to be modified to suit constructional features, e.g. the spacing and width of transverse beam sections of the structure. 6.2.7 Light sources The choice of light source is governed by functional, economic and aesthetic consideration

42、s. For some complex junctions, there may be advantages in lighting the section of local road within the junction with the same type of light source as that used on its contiguous sections to assist in its demarcation. For example, a local road system crossing an urban motorway and the contiguous sec

43、tions of the local roads may be lighted by a different type of light source from that of the motorway. Licensed Copy: sheffieldun sheffieldun, na, Mon Dec 04 12:35:55 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 5489-5:1992 BSI 12-19983 7 Lighting by high-mast techniques 7.1 General The principal u

44、se of high-mast lighting is to light a number of roads rather than a single road. Where junctions involve a complex system of roads at different levels, high-mast lighting can provide good uniformity and improve the scene by reducing the amount of street furniture with a consequential improvement in

45、 daylight appearance. The mast can support fixed geometry or variable geometry luminaires or floodlights and usually incorporates a means of lowering the luminaires to ground level for maintenance. Figure 3 illustrates lighting by high-mast techniques. 7.2 Design characteristics 7.2.1 General It sho

46、uld be noted that: a) less use is made of preferential reflection from the surfaces of the road and the levels of road surface luminance may be lower than those achieved by other types of installation giving the same levels of illuminance; NOTEThis should be considered when designing in accordance w

47、ith BS 5489-2. b) it is desirable to site masts in accordance with Parts 2 and 4 of this standard to ensure, so far as is possible, that the luminaire to light each section of road is beyond that section of road as seen by the observer for whom the lighting is intended. 7.2.2 Light distribution Indi

48、vidual luminaires may provide a symmetric or an asymmetric light distribution. They may be so grouped as to produce an overall light distribution tailored to match the area to be lit from each mast. Figure 4 illustrates typical high-mast light distributions and Figure 5 shows how individual luminair

49、es may be combined to produce complex light distribution patterns. They should provide a distribution with negligible light at the horizontal and at angles just below the horizontal. Present experience suggests that the beam elevation should lie in the region of 65 from the downward vertical but higher angles may prove to be acceptable. 7.2.3 Design considerations Some of the aspects that should be taken into account are as follows. a) Since the area illuminated by a single high mast may be large, each mast should preferably carry more than one lamp or luminaire and t