ISO-10329-2009.pdf

上传人:椰子壳 文档编号:3773669 上传时间:2019-09-23 格式:PDF 页数:16 大小:243.80KB
返回 下载 相关 举报
ISO-10329-2009.pdf_第1页
第1页 / 共16页
ISO-10329-2009.pdf_第2页
第2页 / 共16页
ISO-10329-2009.pdf_第3页
第3页 / 共16页
ISO-10329-2009.pdf_第4页
第4页 / 共16页
ISO-10329-2009.pdf_第5页
第5页 / 共16页
亲,该文档总共16页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《ISO-10329-2009.pdf》由会员分享,可在线阅读,更多相关《ISO-10329-2009.pdf(16页珍藏版)》请在三一文库上搜索。

1、 Reference number ISO 10329:2009(E) ISO 2009 INTERNATIONAL STANDARD ISO 10329 First edition 2009-02-01 Coal Determination of plastic properties Constant-torque Gieseler plastometer method Charbon Dtermination des proprits plastiques Mthode du plastomtre Gieseler couple constant Copyright Internation

2、al Organization for Standardization Provided by IHS under license with ISO Licensee=HP Monitoring/1111111164 Not for Resale, 04/07/2009 23:57:19 MDTNo reproduction or networking permitted without license from IHS -,-,- ISO 10329:2009(E) PDF disclaimer This PDF file may contain embedded typefaces. In

3、 accordance with Adobes licensing policy, this file may be printed or viewed but shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this file, parties accept therein the responsibility of not infringing Ado

4、bes licensing policy. The ISO Central Secretariat accepts no liability in this area. Adobe is a trademark of Adobe Systems Incorporated. Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation parameters were optimized for

5、 printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below. COPYRIGHT PROTECTED DOCUMENT ISO 2009 All rights reserved. Unless oth

6、erwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISOs member body in the country of the requester. ISO copyrig

7、ht office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland ii ISO 2009 All rights reserved Copyright International Organization for Standardization Provided by IHS under license with ISO Licensee=HP Monito

8、ring/1111111164 Not for Resale, 04/07/2009 23:57:19 MDTNo reproduction or networking permitted without license from IHS -,-,- ISO 10329:2009(E) ISO 2009 All rights reserved iii Contents Page Foreword iv 1 Scope . 1 2 Normative references. 1 3 Terms and definitions. 1 4 Principle. 2 5 Apparatus 2 6 C

9、alibration . 3 7 Sample . 4 8 Procedure 4 9 Cleaning of the apparatus 10 10 Calculation and expression of results 10 11 Precision of the method. 11 Copyright International Organization for Standardization Provided by IHS under license with ISO Licensee=HP Monitoring/1111111164 Not for Resale, 04/07/

10、2009 23:57:19 MDTNo reproduction or networking permitted without license from IHS -,-,- ISO 10329:2009(E) iv ISO 2009 All rights reserved Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparin

11、g International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liai

12、son with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of t

13、echnical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is d

14、rawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 10329 was prepared by Technical Committee ISO/TC 27, Solid mineral fuels, Subcommittee SC 5, Methods of analysi

15、s. Copyright International Organization for Standardization Provided by IHS under license with ISO Licensee=HP Monitoring/1111111164 Not for Resale, 04/07/2009 23:57:19 MDTNo reproduction or networking permitted without license from IHS -,-,- INTERNATIONAL STANDARD ISO 10329:2009(E) ISO 2009 All rig

16、hts reserved 1 Coal Determination of plastic properties Constant-torque Gieseler plastometer method 1 Scope This International Standard specifies a method for obtaining a relative measure of the plastic behaviour of coal when heated under prescribed conditions. The method may be used to obtain value

17、s of the plastic properties of coals and blends used in carbonization and in other situations where determination of plastic behaviour of coals is of practical importance. NOTE The empirical nature of this test requires proper equipment calibration to produce fluidity readings which are a true indic

18、ation of the relative plastic behaviour of the coal. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (includin

19、g any amendments) applies. ISO 18283, Hard coal and coke Manual sampling ISO 13909-1, Hard coal and coke Mechanical sampling Part 1: General introduction ISO 13909-2, Hard coal and coke Mechanical sampling Part 2: Coal Sampling from moving streams ISO 13909-3, Hard coal and coke Mechanical sampling

20、Part 3: Coal Sampling from stationary lots 3 Terms and definitions For the purposes of this document, the following terms and definitions apply 3.1 dial division per minute measure of stirrer rotation rate, as used in this method NOTE There are 100 dial divisions for each full 360 rotation of the st

21、irrer. The fluidity result is expressed as total dial divisions turned by the stirrer in a 1 min time period, i.e. dd/min. 3.2 initial softening temperature temperature at which dial movement or electronic readout indicates a stirring shaft movement of one dial division per minute (dd/min), with con

22、tinued indication of movement of at least 1 dd/min thereafter 3.3 maximum fluidity temperature temperature at which stirring shaft rotation reaches the maximum rate 3.4 plastic range difference between the initial softening temperature and the solidification temperature Copyright International Organ

23、ization for Standardization Provided by IHS under license with ISO Licensee=HP Monitoring/1111111164 Not for Resale, 04/07/2009 23:57:19 MDTNo reproduction or networking permitted without license from IHS -,-,- ISO 10329:2009(E) 2 ISO 2009 All rights reserved 3.5 final fluidity temperature temperatu

24、re at which the last 1 dd/min stirrer rotation rate is reached 3.6 solidification temperature temperature at which the stirring shaft stops 3.7 maximum fluidity maximum rate of rotation for the stirring shaft in dial divisions per minute 3.8 jamming swelling up of coal into the retort tube during th

25、e test, which may produce a lower fluidity result than expected and can only be noted after visual inspection of the disassembled crucible and retort at the conclusion of the test 3.9 breaking free spinning behaviour of coal, either by rotating at maximum motor speed or by abrupt changes in rotation

26、, which occurs as a result of a molten ball of coal forming around the base of the stirrer, and which makes reporting of the true maximum fluidity of the coal difficult 4 Principle Measurements of the plastic properties of coals are made by applying a constant torque to a stirrer placed in a crucibl

27、e into which the coal is charged. The crucible is immersed in a bath and the temperature increased uniformly. The rotation of the stirrer is recorded in relation to increase in temperature. 5 Apparatus 5.1 Gieseler plastometer retort, composed of the following component parts (see Figure 1). 5.1.1 R

28、etort crucible, cylindrical, with (21,4 0,1) mm inside diameter, and (35,0 0,3) mm in depth with exterior threads for joining the crucible to the barrel. The crucible shall have a (2,38 0,02) mm diameter notch with an included angle of 70 in the centre of its inside base to serve as a seat for the s

29、tirrer. 5.1.2 Retort crucible cover, with interior threads for joining the crucible cover to the crucible and exterior threads for joining the crucible cover to the barrel. The inside diameter of the hole which accommodates the stirrer shall be (9,5 0,1) mm. 5.1.3 Guide sleeve, provided near the upp

30、er end of the stirrer to guide the latter within the barrel with a clearance of between 0,05 mm and 0,10 mm. 5.1.4 Gas exit hole, provided on the barrel to afford an exit for the volatile products during a test, placed, for example, at the midpoint of the barrel; a tube may be fitted if desired. 5.1

31、.5 Barrel, (121,0 2,5) mm long, having an inside diameter of (9,5 0,1) mm. The top end of the barrel shall be 12,7 mm in inside diameter to a depth sufficient to allow the fitting of a guide sleeve through which the axle of the stirrer passes when the apparatus is assembled. Copyright International

32、Organization for Standardization Provided by IHS under license with ISO Licensee=HP Monitoring/1111111164 Not for Resale, 04/07/2009 23:57:19 MDTNo reproduction or networking permitted without license from IHS -,-,- ISO 10329:2009(E) ISO 2009 All rights reserved 3 5.1.6 Steel stirrer, provided with

33、a straight shaft (3,95 0,05) mm in diameter and equipped with four rabble arms. The lower end of the stirrer shall be tapered to a point having an included angle of 60. The rabble arms on the stirrer shall be (1,6 0,05) mm in diameter, (6,4 0,05) mm in length, and shall be placed so as to be perpend

34、icular to the shaft at 90 intervals around the shaft and (3,2 0,05) mm apart centre to centre along the shaft. The middle two rabble arms shall be set at 180 to each other, and likewise, the remaining two arms at 180 to each other. The lowest rabble arm shall be set to give (1,6 0,05) mm clearance b

35、etween it and the bottom of the crucible when the stirrer is in place. The upper end of the stirrer shall be cut to fit into a slot on the lower end of the axle in the plastometer head. The rabble arms should be checked before each test to ensure that they are clean and free from distortion or other

36、 visual damage. It is essential that the dimensions of the rabble arms on the stirrer meet the requirements in this clause and in Figure 2, and it is important that these dimensions are checked on a regular basis, e.g. every 50 determinations. If after use it is found by accurate measurement that an

37、y of the dimensions are outside the specified limits, the rabble arms should be replaced or the stirrer discarded. 5.2 Plastometer head. The plastometer head, shown schematically in Figure 3, shall consist of a fixed-speed motor (approximately 300 r/min to 500 r/min) connected directly to a magnetic

38、 clutch or hysteresis brake capable of adjustment over a reasonable range either side of a torque value of 101,6 gcm (9,66 Nm). A dial drum, attached to the clutch brake output shaft, shall be graduated into 100 divisions for 360 degrees. Each complete drum revolution or 100 dial divisions shall be

39、recorded on a counter actuated by an electric eye or other suitable method. As an alternative, an electronic device capable of measuring rotation rates between 0,01 and 300 r/min may be attached to the clutch or brake output shaft. Using this latter technique, rotation rates can be converted directl

40、y to dial divisions per minute (dd/min) and can be displayed or recorded once a minute on a suitable electronic readout or printer. NOTE Care is needed in the maintenance and lubrication of all bearings, particularly after the instrument has been used with a coal high in volatile matter. Using beari

41、ngs with a closed race is undesirable due to the increased friction of the closed race compared to bearings with an open race. When using open race bearings, clean and replace on a regular basis. 5.3 Electric Furnace. An electrically heated furnace shall be used (see Figure 4) with suitable controls

42、 so that a heating rate of (3,0 0,1) C/min, on an overall basis, with not more than (3,0 1,0) C for any given minute, can be maintained over a temperature range from 300 C to 550 C with a (15 1) C rise over any given 5 min period. The furnace shall contain a molten solder bath of approximately 50 pe

43、rcent lead and 50 percent tin composition. The temperature in the bath shall be measured with a suitable thermocouple in a protection tube of approximately 6 mm in outside diameter immersed in the bath so that the tube touches the outside wall of the crucible and the hot junction of the thermocouple

44、 is at the same height as the centre of the coal charge. A stirrer shall be used to agitate the solder. 5.4 Loading device. The loading device shall be provided to pack the coal uniformly in the crucible under a total load of 10 kg and designed in such a manner that, after compression, the crucible

45、and its contents can be removed easily from the device without disturbing the contents. A suitable device, such as shown in Figure 5, has a static weight of 9 kg together with a drop weight of 1 kg which is dropped twelve times from a height of 115 mm. NOTE The static weight of 9 kg is the combined

46、mass of the cage, packing head, dropping mass shaft and the static mass. 6 Calibration Torque shall be checked with the string and pulley method shown in Figure 6. In the string and pulley method, a pulley is screwed onto the spindle and a string attached to this pulley is placed over a second verti

47、cal pulley, with the required weight attached. A 25,4 mm (1 in) radius pulley and a 40 g weight have been used for that purpose. With the plastometer motor turned on, the brake or clutch suspension, or the torque gauge or Copyright International Organization for Standardization Provided by IHS under

48、 license with ISO Licensee=HP Monitoring/1111111164 Not for Resale, 04/07/2009 23:57:19 MDTNo reproduction or networking permitted without license from IHS -,-,- ISO 10329:2009(E) 4 ISO 2009 All rights reserved transducer, reads (101,6 5,1) gcm (40,0 2,0) gin. All instruments should be checked in this manner as required, at a predetermined frequency based on the laboratorys experimentation on stability or torque setting. Alternatively, torque can be checked with a suita

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 其他


经营许可证编号:宁ICP备18001539号-1