1、 Reference number ISO 1179-3:2007(E) ISO 2007 INTERNATIONAL STANDARD ISO 1179-3 First edition 2007-08-15 Connections for general use and fluid power Ports and stud ends with ISO 228-1 threads with elastomeric or metal-to-metal sealing Part 3: Light-duty (L series) stud ends with sealing by O-ring wi

2、th retaining ring (types G and H) Raccordements pour applications gnrales et transmissions hydrauliques et pneumatiques Orifices et lments mles filetage ISO 228-1 et joint en lastomre ou tanchit mtal sur mtal Partie 3: lments mles srie lgre (srie L) avec tanchit par joint torique et bague de retenue

3、 (types G et H) ISO 1179-3:2007(E) PDF disclaimer This PDF file may contain embedded typefaces. In accordance with Adobes licensing policy, this file may be printed or viewed but shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the

4、editing. In downloading this file, parties accept therein the responsibility of not infringing Adobes licensing policy. The ISO Central Secretariat accepts no liability in this area. Adobe is a trademark of Adobe Systems Incorporated. Details of the software products used to create this PDF file can

5、 be found in the General Info relative to the file; the PDF-creation parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event that a problem relating to it is found, please inform the Central Secretariat

6、 at the address given below. COPYRIGHT PROTECTED DOCUMENT ISO 2007 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing fro

7、m either ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland ii ISO 2007 All rights reserved ISO 1179-3:2007(

8、E) ISO 2007 All rights reserved iii Contents Page Foreword iv Introduction v 1 Scope . 1 2 Normative references. 1 3 Terms and definitions. 2 4 Dimensions 2 5 Requirements 2 6 Sealing . 2 7 Test methods. 3 8 Designation of stud ends. 4 9 Identification statement (reference to this part of ISO 1179).

9、 5 Annex A (normative) Test data form for ISO 1179-1 port and ISO 1179-3 stud ends 12 Bibliography. 13 -,-,- ISO 1179-3:2007(E) iv ISO 2007 All rights reserved Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies)

10、. The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non

11、-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part

12、 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting

13、a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 1179-3 was prepared by Technical Committee ISO/TC 131, Fluid power systems, Subcommittee

14、SC 4, Connectors and similar products and components. This first edition of ISO 1179-3, together with ISO 1179-1, ISO 1179-2 and ISO 1179-4, cancels and replaces ISO 1179:1981 which has been technically revised. ISO 1179 consists of the following parts, under the general title Connections for genera

15、l use and fluid power Ports and stud ends with ISO 228-1 threads with elastomeric or metal-to-metal sealing: Part 1: Threaded ports Part 2: Heavy-duty (S series) and light-duty (L series) stud ends with elastomeric sealing (type E) Part 3: Light-duty (L series) stud ends with sealing by O-ring with

16、retaining ring (types G and H) Part 4: Stud ends for general use only with metal-to-metal sealing (type B) ISO 1179-3:2007(E) ISO 2007 All rights reserved v Introduction In fluid power systems, power is transmitted and controlled through a fluid (liquid or gas) under pressure within a circuit. In ge

17、neral applications, a fluid may be conveyed under pressure. Components are connected through their threaded ports by fluid conductor connectors to tubes and pipes or to hose fittings and hoses. For threaded ports and stud ends specified in new designs in hydraulic fluid power applications, ISO/TC 13

18、1/SC 4 recommends that the ISO 6149 series be used because these International Standards specify ports and stud ends with metric threads and O-ring sealing and because the sub-committee would like to help users by recommending one preferred system. ISO/TC 131/SC 4 further recommends that threaded po

19、rts and stud ends in accordance with the ISO 1179 series, ISO 9974 series and ISO 11926 series not be used for new designs in hydraulic fluid power applications; these International Standards will be maintained because they specify ports and stud ends that are currently used in hydraulic systems wor

20、ldwide. For threaded ports and stud ends specified in new designs in pneumatic fluid power applications, ISO/TC 131/SC 4 recommends that ISO 16030 be used, except where products are to interface with ISO 7-1 threads, because the sub-committee would like to help users by recommending one preferred sy

21、stem. ISO/TC 131/SC 4 further recommends that threaded ports and stud ends in accordance with the ISO 1179 series not be used for new designs in pneumatic fluid power applications; these International Standards will be maintained because they specify ports and stud ends that are currently used in pn

22、eumatic systems worldwide. Significant testing over more than 30 years of use has confirmed the performance requirements of connection ends made from carbon steel. The stud end connections specified in ISO 1179 parts 2, 3 and 4 apply to connectors detailed in ISO 8434 parts 1, 2 and 4. -,-,- -,-,- I

23、NTERNATIONAL STANDARD ISO 1179-3:2007(E) ISO 2007 All rights reserved 1 Connections for general use and fluid power Ports and stud ends with ISO 228-1 threads with elastomeric or metal-to-metal sealing Part 3: Light-duty (L series) stud ends with sealing by O-ring with retaining ring (types G and H)

24、 1 Scope This part of ISO 1179 specifies dimensions, performance requirements and test procedures for non-adjustable and adjustable light-duty (L series) stud ends with ISO 228-1 threads with sealing by O-ring with retaining ring (types G and H, respectively). Light-duty (L series) stud ends in acco

25、rdance with this part of ISO 1179 may be used at working pressures up to 31,5 MPa (315 bar) for non-adjustable stud ends (type G) and up to 20 MPa (200 bar) for adjustable stud ends (type H). The permissible working pressure depends upon size, materials, design, working conditions, application, etc.

26、 Conformance to the dimensional information in this part of ISO 1179 does not guarantee rated performance. Each manufacturer shall perform testing according to the specification contained in this part of ISO 1179 to assure that components made to this part of ISO 1179 comply with the performance rat

27、ings. NOTE 1 This part of ISO 1179 applies to connectors detailed in ISO 8434-2. NOTE 2 The introduction of this part of ISO 1179 gives recommendations for ports and stud ends to be used for new designs in hydraulic and pneumatic fluid power applications. 2 Normative references The following referen

28、ced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 228-1, Pipe threads where pressure-tight joints are not made on th

29、e threads Part 1: Dimensions, tolerances and designation ISO 3601-3:2005, Fluid power systems O-rings Part 3: Quality acceptance criteria ISO 4759-1:2000, Tolerances for fasteners Part 1: Bolts, screws, studs and nuts Product grades A, B and C ISO 5598, Fluid power systems and components Vocabulary

30、ISO 19879, Metallic tube connections for fluid power and general use Test methods for hydraulic fluid power connections -,-,- ISO 1179-3:2007(E) 2 ISO 2007 All rights reserved 3 Terms and definitions For the purposes of this document, the terms and definitions given in ISO 5598 and the following app

31、ly. 3.1 adjustable stud end connector stud end connector that allows for connector orientation through final tightening of the locknut to complete the connection NOTE This type of stud end is typically used on shaped connectors (e.g. tees, crosses and elbows). 3.2 non-adjustable stud end connector s

32、tud end connector that does not require specific orientation before final tightening of the connection because it is only used on straight connectors 4 Dimensions Light-duty (L series) type G and type H stud ends, locknuts and washers shall conform to the dimensions given in Figures 1 and 2 and Tabl

33、e 1. Hexagonal tolerances across flats shall be in accordance with ISO 4759-1:2000, product grade C. 5 Requirements 5.1 Working pressure Light-duty (L series) stud ends (types G and H) made of low carbon steel shall be designed for use at the working pressures given in Table 2. 5.2 Performance Light

34、-duty (L series) stud ends made of low carbon steel shall meet or exceed the burst and impulse pressures given in Table 2, when tested in accordance with Clause 7 and assembled using the torques listed in Table 6. 5.3 Flatness and fit of adjustable stud end back-up washers The washer shall be clinch

35、ed to the stud end with a tight slip fit to an interference fit. The slip fit shall be tight enough so that the washer cannot be shaken loose to cause it to drop from its uppermost position under its own weight. The locknut torque needed to move the washer at the maximum washer interference fit shal

36、l not exceed the torques listed in Table 3. Any washer surface that is out of flatness shall be uniform (i.e. not wavy) and concave with respect to the stud end of type H stud ends only and shall conform to the allowance given in Table 3. 6 Sealing O-rings and retaining rings for use with light-duty

37、 (L series) stud ends shall conform to the dimensions given in Figures 3 and 4 and Tables 4 and 5. Figures 5 and 6 show the correct assembly of the stud end with O-ring and retaining ring. ISO 1179-3:2007(E) ISO 2007 All rights reserved 3 7 Test methods 7.1 Burst pressure test (failure pressure test

38、) 7.1.1 Principle Three samples shall be tested to confirm that light-duty (L series) stud ends meet or exceed a ratio of 4:1 between the burst and working pressures. 7.1.2 Materials 7.1.2.1 Test block and stud ends Test blocks shall be in accordance with the requirements specified in ISO 19879. Stu

39、d ends shall be made from low carbon steel and be plated. 7.1.2.2 Test seals Unless otherwise specified, test seals shall meet the requirements specified in ISO 19879. Seals shall conform to the dimensions given in Tables 4 and 5, and O-rings shall meet or exceed the quality requirement grade N in I

40、SO 3601-3:2005. 7.1.3 Procedure 7.1.3.1 Thread lubrication For testing only, threads and contact surfaces shall be lubricated in accordance with the requirements of ISO 19879. 7.1.3.2 Stud end torque Stud ends shall be tested after application of the torques given in Table 6. Adjustable stud end loc

41、knut torques shall be applied after the stud end has been backed out one full turn from finger tight position, to correctly test the worst possible actual assembly conditions. 7.1.3.3 Pressure rise rate The rate of pressure rise shall be in accordance with the requirements of ISO 19879. 7.2 Cyclic e

42、ndurance (impulse) test 7.2.1 Principle Six samples, when tested at their respective impulse pressures, shall pass a cyclic endurance test of 1 000 000 cycles without leakage or component failure. 7.2.2 Materials Use the same materials as specified in 7.1.2. -,-,- ISO 1179-3:2007(E) 4 ISO 2007 All r

43、ights reserved 7.2.3 Procedure 7.2.3.1 Thread lubrication Apply lubricant as specified in 7.1.3.1. 7.2.3.2 Stud end torques Apply torque as specified in 7.1.3.2. 7.2.3.3 Cycle and pressure rise rate The cycle rate shall be in accordance with the requirements of ISO 19879, except the rate of pressure

44、 rise shall be adjusted accordingly. 7.3 Test report Test results and conditions shall be reported on the test data form given in Annex A. 7.4 Re-use of components Parts used for cyclic endurance or burst tests shall not be tested further, used or returned to stock. 8 Designation of stud ends 8.1 St

45、ud ends shall be designated by: a) “Stud end”; b) reference to this part of ISO 1179, i.e. ISO 1179-3; c) thread size; d) a letter “G” to designate type G sealing or letter “H” to designate type H sealing. EXAMPLE A stud end with a G 3/8 A thread in accordance with ISO 228-1 with type G sealing is d

46、esignated as follows: Stud end ISO 1179-3 - G 3/8 A - G 8.2 The O-ring shall be designated by the word “O-ring,” followed by “ISO 1179-3”, followed by the thread size of the stud end with which it is used. Retaining ring shall be designated by the phrase “Retaining ring”, followed by ISO 11793”, fol

47、lowed by the thread size of the stud end with which it is used. EXAMPLE 1 An O-ring for use with a size G 1/8 A stud end in accordance with ISO 1179-3 is designated as follows: O-ring ISO 1179-3 - G 1/8 EXAMPLE 2 A retaining ring for use with a size G 1/4 A stud end in accordance with ISO 1179-3 is

48、designated as follows: Retaining ring ISO 1179-3 - G 1/4 -,-,- ISO 1179-3:2007(E) ISO 2007 All rights reserved 5 9 Identification statement (reference to this part of ISO 1179) It is strongly recommended to manufacturers who have chosen to conform to this part of ISO 1179 that the following statement be used in test reports, catalogues and sales literature. “Light-duty (L series) stud end conforms to ISO 1179-3, Connections for general use and fluid power Ports and stud ends with ISO 228-1 threads with elastomeric or metal-to-metal s