ISO-15767-2003.pdf

上传人:韩长文 文档编号:3777970 上传时间:2019-09-23 格式:PDF 页数:26 大小:260.48KB
返回 下载 相关 举报
ISO-15767-2003.pdf_第1页
第1页 / 共26页
ISO-15767-2003.pdf_第2页
第2页 / 共26页
ISO-15767-2003.pdf_第3页
第3页 / 共26页
ISO-15767-2003.pdf_第4页
第4页 / 共26页
ISO-15767-2003.pdf_第5页
第5页 / 共26页
亲,该文档总共26页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《ISO-15767-2003.pdf》由会员分享,可在线阅读,更多相关《ISO-15767-2003.pdf(26页珍藏版)》请在三一文库上搜索。

1、 Reference number ISO 15767:2003(E) ISO 2003 INTERNATIONAL STANDARD ISO 15767 First edition 2003-02-15 Workplace atmospheres Controlling and characterizing errors in weighing collected aerosols Atmosphres des lieux de travail Contrle et caractrisation des erreurs de pese des arosols collects Copyrig

2、ht International Organization for Standardization Provided by IHS under license with ISO Licensee=NASA Technical Standards 1/9972545001 Not for Resale, 04/18/2007 20:27:37 MDTNo reproduction or networking permitted without license from IHS -,-,- ISO 15767:2003(E) PDF disclaimer This PDF file may con

3、tain embedded typefaces. In accordance with Adobes licensing policy, this file may be printed or viewed but shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this file, parties accept therein the responsib

4、ility of not infringing Adobes licensing policy. The ISO Central Secretariat accepts no liability in this area. Adobe is a trademark of Adobe Systems Incorporated. Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation pa

5、rameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below. ISO 2003 All rights reserved. Unless other

6、wise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISOs member body in the country of the requester. ISO copyright

7、 office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland ii ISO 2003 All rights reserved Copyright International Organization for Standardization Provided by IHS under license with ISO Licensee=NASA Techni

8、cal Standards 1/9972545001 Not for Resale, 04/18/2007 20:27:37 MDTNo reproduction or networking permitted without license from IHS -,-,- ISO 15767:2003(E) ISO 2003 All rights reserved iii Contents Page Forewordiv Introduction v 1 Scope1 2 Normative references .1 3 Terms and definitions.1 4 Weight in

9、stability Causes and minimization .2 4.1 General.2 4.2 Moisture sorption2 4.3 Electrostatic effects3 4.4 Effects of volatile compounds (other than water) .3 4.5 Handling damage 4 4.6 Buoyancy changes .4 5 Correcting for weight instability by use of blanks 4 5.1 General.4 5.2 Minimum number of blanks

10、 .4 5.3 Weighing times and sequence 4 5.4 Conditioning times5 5.5 Storage stability 5 6 Transport of samples to laboratory 5 6.1 General.5 6.2 Recommended packaging5 7 Weighing equipment and procedure.6 7.1 The balance .6 7.2 Recommended environmental controls .6 7.3 Other equipment requirements6 7.

11、4 Procedure.7 8 Recommendations for the reporting of measured mass relative to LOD and LOQ.7 Annex A (normative) Estimation of measurement errors 8 Annex B (informative) Interpretation of LOD and LOQ.12 Annex C (informative) Method evaluation example 14 Annex D (normative) Test of transportation int

12、egrity.15 Bibliography .17 Copyright International Organization for Standardization Provided by IHS under license with ISO Licensee=NASA Technical Standards 1/9972545001 Not for Resale, 04/18/2007 20:27:37 MDTNo reproduction or networking permitted without license from IHS -,-,- ISO 15767:2003(E) iv

13、 ISO 2003 All rights reserved Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interes

14、ted in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical C

15、ommission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the tech

16、nical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO

17、shall not be held responsible for identifying any or all such patent rights. ISO 15767 was prepared by Technical Committee ISO/TC 146, Air quality, Subcommittee SC 2, Workplace atmospheres. Copyright International Organization for Standardization Provided by IHS under license with ISO Licensee=NASA

18、Technical Standards 1/9972545001 Not for Resale, 04/18/2007 20:27:37 MDTNo reproduction or networking permitted without license from IHS -,-,- ISO 15767:2003(E) ISO 2003 All rights reserved v Introduction Assessment of airborne aerosol hazards in the occupational setting entails sampling onto a coll

19、ection medium, followed by analysis of the collected material. The result is generally an estimated concentration of a hazardous material in the air. The accuracy of such estimates depends on several factors, one of which relates to the specific type of analysis employed. This International Standard

20、 deals with a specific type of analysis which finds the most general application in the sampling of aerosols, namely the weighing of sampled material. Gravimetric analysis, though apparently simple, is subject to errors from instability in the mass of the sampling medium and other elements which mus

21、t be weighed. An example is provided by aerosol samplers designed to collect particles so as to agree with the inhalable aerosol sampling convention. For some sampler types, filter and cassette are weighed together to make estimates. Therefore, if the cassette, for example, absorbs or loses water be

22、tween the weighings required for a concentration estimation, then errors may arise. This International Standard describes such potential errors and provides solutions for their minimization. Copyright International Organization for Standardization Provided by IHS under license with ISO Licensee=NASA

23、 Technical Standards 1/9972545001 Not for Resale, 04/18/2007 20:27:37 MDTNo reproduction or networking permitted without license from IHS -,-,- Copyright International Organization for Standardization Provided by IHS under license with ISO Licensee=NASA Technical Standards 1/9972545001 Not for Resal

24、e, 04/18/2007 20:27:37 MDTNo reproduction or networking permitted without license from IHS -,-,- INTERNATIONAL STANDARD ISO 15767:2003(E) ISO 2003 All rights reserved 1 Workplace atmospheres Controlling and characterizing errors in weighing collected aerosols 1 Scope This International Standard prov

25、ides recommendations for controlling the analytical uncertainty associated with aerosol collection medium instability, where collection medium or substrate includes any article used to collect particles (e.g. filter or foam material) as well as those supporting elements which must be analysed by wei

26、ghing. This International Standard is applicable to results compiled both from the literature and, if necessary and feasible, through laboratory experiment. Expected errors associated with given aerosol capture methods are quantified where possible. Recommendations as to materials to be used are giv

27、en. Means of controlling or correcting errors arising from instability are provided. Recommendations for the weighing procedure are given. A procedure for estimating weighing errors is described. Finally, recommendations are given for the reporting of measured masses. 2 Normative references The foll

28、owing referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 7708, Air quality Particle size fraction definitions

29、for health-related sampling EN 482, Workplace atmospheres General requirements for performance of procedures for the measurement of chemical agents EN 13205:2001, Workplace atmospheres Assessment of performance of instruments for measurement of airborne particle concentrations 3 Terms and definition

30、s For the purposes of this document, the following terms and definitions apply. 3.1 substrate aerosol sampling filter, foam, etc., together with whatever mounting is weighed as a single item NOTE As an example of the converse, the 25-mm or 37-mm plastic filter cassette often used for “total dust” sa

31、mpling in either its closed-face or open-face version is not part of the substrate in the definition above, since it is not weighed. Copyright International Organization for Standardization Provided by IHS under license with ISO Licensee=NASA Technical Standards 1/9972545001 Not for Resale, 04/18/20

32、07 20:27:37 MDTNo reproduction or networking permitted without license from IHS -,-,- ISO 15767:2003(E) 2 ISO 2003 All rights reserved 3.2 equilibration time time constant characterizing an approximately exponentially damped approach of the mass of an aerosol collection medium to a constant value NO

33、TE 1 The constant can be defined as the mean difference of the mass from equilibrium per mean mass loss or gain rate as measured over a finite time interval. NOTE 2 There may be important instances in which several time constants are required to describe the approach to equilibrium. NOTE 3 Equilibra

34、tion time is expressed in seconds. 3.3 field blank blank substrate that undergoes the same handling as the sample substrate, generally including conditioning and, often, loading into the samplers or transport containers, as well as transportation between lab and sampling site, but without being expo

35、sed to sampling 3.4 lab blank blank substrate that undergoes the same handling as the sample substrate in the laboratory, including conditioning and loading into the samplers or transport containers if this is done in the laboratory 3.5 blank substrate collection medium or substrate taken from the s

36、ame batch as the sampling medium, but unexposed to sampling 3.6 limit of detection LOD three times the estimated standard deviation of the mass of the sample, accounting for the double weighing (exposed vs. unexposed) and for the uncertainty associated with any correction blanks used NOTE The value

37、LOD can be used as a threshhold value to assert the presence of a substance with confidence in the method. Annex B describes how to estimate, on the basis of the method evaluation, the false positive rate in such assertions. 3.7 limit of quantitation LOQ ten times the estimated standard deviation of

38、 the mass of the sample NOTE The value LOQ can be used as a threshhold value to assure measurement of a substance accurately. For details, see Annex B. 4 Weight instability Causes and minimization 4.1 General Weight instability of sampling substrates can be attributed to several causes 1 to 11. The

39、following subclauses address the more important of these. 4.2 Moisture sorption 4.2.1 Moisture sorption is the most common cause of weight instability. Water can be directly collected by the filter or foam or other substrate material that is weighed. Water sorption by any part of the sampling system

40、 which is weighed must be suspected as well. For example, the sampling cassette itself, if weighed, can be the cause of significant error 1. Copyright International Organization for Standardization Provided by IHS under license with ISO Licensee=NASA Technical Standards 1/9972545001 Not for Resale,

41、04/18/2007 20:27:37 MDTNo reproduction or networking permitted without license from IHS -,-,- ISO 15767:2003(E) ISO 2003 All rights reserved 3 4.2.2 The effects of water sorption can be reduced by using non-sorptive materials. However, there may exist specific sampling needs for which a hydrophobic

42、material is not feasible. Table 1 presents a list of common aerosol sampling substrates with different water adsorption features. Table 1 Water sorption characteristics of some aerosol sampling media Water sorption Substrate or cassette type Very low Low High Very high Cellulose fibre filter * Glass

43、 fibre filter * Quartz fibre filter * Cellulose ester membrane filter * Polytetrafluoroethylene filter * PVC membrane filter * * Polycarbonate filter * Silver membrane filter * Polyurethane foam * Greased Mylar impaction substrate * * Greased aluminium foil impaction substrate * Carbon-filled resin

44、* Aluminium cassette * * Stainless steel cassette * NOTE 1 References 2 to 4 provide further details. Also, reference 5 reports that filters of evidently the same material, but originating from different manufacturers, can have widely differing variabilities. NOTE 2 There is generally a trade-off be

45、tween hydrophobicity and conductivity in many materials 9. Therefore, one must be aware of the possibility of creating sampling problems when reducing hygroscopicity. NOTE 3 Pre-treatments of substrates, such as greasing, can also affect water sorption. 4.3 Electrostatic effects Electrostatic effect

46、s are a common source of weighing problems. These effects can usually be minimized by discharging the substrate through the use of a plasma ion source or a radioactive source. Using conductive materials may reduce such problems. See also reference 7. 4.4 Effects of volatile compounds (other than wat

47、er) 4.4.1 Volatile compounds can be present in unused collection media 3, or can be adsorbed onto media during sampling. 4.4.2 Desorption of volatiles from unused media can be controlled, for example, by heating or oxygen plasma treatment prior to conditioning and weighing. Alternatively, losses may

48、 be compensated by the use of blanks (see Clause 5). 4.4.3 When volatile materials collected during sampling form part of the intended sample, standardized written procedures are required to ensure that any losses are minimized or at least controlled, for example by conditioning under tightly specified conditions. Copyright International Organization for Standardization Provided by IHS under license with ISO Licensee=NASA Technical Standards 1

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 其他


经营许可证编号:宁ICP备18001539号-1