JIS-B-0011-1-1998-R2003-ENG.pdf

上传人:韩长文 文档编号:3783765 上传时间:2019-09-23 格式:PDF 页数:21 大小:813.75KB
返回 下载 相关 举报
JIS-B-0011-1-1998-R2003-ENG.pdf_第1页
第1页 / 共21页
JIS-B-0011-1-1998-R2003-ENG.pdf_第2页
第2页 / 共21页
JIS-B-0011-1-1998-R2003-ENG.pdf_第3页
第3页 / 共21页
JIS-B-0011-1-1998-R2003-ENG.pdf_第4页
第4页 / 共21页
JIS-B-0011-1-1998-R2003-ENG.pdf_第5页
第5页 / 共21页
亲,该文档总共21页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《JIS-B-0011-1-1998-R2003-ENG.pdf》由会员分享,可在线阅读,更多相关《JIS-B-0011-1-1998-R2003-ENG.pdf(21页珍藏版)》请在三一文库上搜索。

1、STDeJIS B 0011-1-ENGL 1998 M 4933b08 055628b Lb0 M J IS JAPANESE INDUSTRIAL STANDARD Translated and Published by J a pa nese Standards Association JIS B 0011-1 11998 (IS0 6412-1 1989) Technical drawings-Simplified representat ion of pipelines- Part 1 :General rules and orthogonal representation ICs

2、01.100.01; 23.040.01 Descriptors : pipelines, pipework systems, pipes, technical drawing, projection Reference number : JIS B 0011-1 : 1998 (E) (drawing), drawings 11s Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie

3、Not for Resale, 03/15/2007 22:54:04 MDTNo reproduction or networking permitted without license from IHS -,-,- STD=JIS B OOLf-1-ENGL 1998 M 4933b08 055b287 OT7 B 0011-1 : 1998 (IS0 6412-1 : 1989) Foreword This translation has been made based on the original Japanese Industrial Standard revised by the

4、 Minister of International Trade and Industry through deliberations at Japanese Industrial Standards Committee in accordance with the Industrial Standardization Law. Consequently JIS Z 8205 : 1995 is revised and replaced with JIS B 0011-1 : 1998, JIS B 0011-2 : 1998 and JIS B 0011-3 : 1998. JIS B O0

5、11 consists of the following parts, under the general title Technical drawings-simplifed representation of pipelines: Part 1 : General rules and orthogonal representation Part 2 :Isometric projection Part 3 : Terminal features of ventilation and drainage systems Date of Establishment: 1998-01-20 Dat

6、e of Public Notice in Official Gazette: 1998-01-20 Investigated by: Japanese Industrial Standards Committee Divisional Council on Machine Elements JIS B 0011-1 : 1998, First English edition published in 1999-08 Translated and published by: Japanese Standards Association 4-1-24, Akasaka, Minato-ku, T

7、okyo, 107-8440 JAPAN In the event of any doubts arising as to the contents, the original JIS is to be the final authority. . . O JSA 1999 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical,

8、including photocopying and microfilm, without permission in writing from the publisher. Printed in Japan Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/15/2007 22:54:04 MDTNo reproduction or netwo

9、rking permitted without license from IHS -,-,- STDOJIS B 0011-1-ENGL 1798 4933b08 055b288 T33 JAPANESE INDUSTRIAL STANDARD JIS B 0011-1 : 1998 (IS0 6412-1 : 1989) Technical drawings-Simplified representation of pipelines- Part 1 : General rules and orthogonal representation Introduction This part of

10、 JIS B O011 has been prepared on the basis of IS0 6412- 1, Technical drawings-Simplified representation of pipelines-Part 1 : General rules and orthogonal representation published in 1989 as the first edition, without modi- fying its technical content and structure. The portions underlined with dots

11、 in the text and Annex 1 (informative) are items not included in the original International Standard. Depending on the information it is intended to convey and the form of represen- tation required, a distinction has to be made between graphical representation by means of orthogonal and that by mean

12、s of isometric representation. This part of JIS B O011 deals, therefore, with general rules used for both repre- sentations (orthogonal and isometric). Rules applicable only to isometric represen- tation are given in JIS B 0011-2. For the purposes of this part of JIS B 0011, all dimensions and toler

13、ances on the drawings have been stencilled in upright lettering. It should be understood that these indications could just as well be written in free-hand or inclined (italic) letter- ing without altering the meaning of the indications. For the presentation of lettering (proportions and dimensions),

14、 see 4 . 4 . 1 Scope This part of JIS B O011 specifies rules and conventions for the execu- tion of simplified drawings for the representation of all kinds of pipes and pipelines made of all sorts of materials (rigid and flexible). It shall be used whenever pipes or pipelines have to be represented

15、in a simpli- fied manner. For the purposes of this part of JIS B 0011, the figures illustrate the text only and should not be considered as design examples. Remarks : This part of JIS B O011 might also be of some use for the represen- tation of similar installations, such as ventilation or air-condi

16、tioning systems; in such cases, the term ?duct?, etc. should be substituted for the term ?pipe?. B 2 Normative references The following standards contain provisions which, through reference in this text, constitute provisions of this part of JIS B 0011. The most recent editions of the standards list

17、ed below (including the amendments) shall be applied. JIS B 0125 Graphic symbols for fluid power systems Remarks : Cited items from IS0 1219 : 1976, Fluid power systems und com- ponents-Graphic symbols are equivalent to the corresponding items of JIS B 0125. _-_._-._ _-_._. ._._. _.-_ _-._-_.-. _._-

18、.-.-.-. ._-._- -_ _-_-_.-.- Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/15/2007 22:54:04 MDTNo reproduction or networking permitted without license from IHS -,-,- 2 B 0011-1 : 1998 (IS0 6412-1

19、: 1989) JIS Z 8312 Technical drawing-Line conventions IS0 3461-2 General principles for the creation of graphical symbols-Part 2 : Graphical symbols for use in technical product documentation IS0 3545 Steel tubes and tubular shaped accessories with circular cross-section- Symbols to be used in speci

20、fications IS0 4067-1 Technical drawings-Installations-Part 1 : Graphical symbols for plumbing, heating, ventilation and ducting IS0 7573 Technical drawings-Item lists 3 Definitions For the purposes of JIS B 0011, the following definitions apply. 3 . 1 angles to the projection plane. orthogonal repre

21、sentation Projection method in which projectors are at right 3 . 2 isometric representation Projection method in which each of the three co- ordinate axes is inclined at the same angle to the projection plane. 3.3 flow line Representation of the flow path of the inlet or outlet streams or of materia

22、l, energy or energy carriers. 4 General principles In this clause all general principles are specified which are common to the methods of projection and to the pictorial representations, as rec- ommended in this part of JIS B 0011. 4.1 Representation of pipes, etc. The flow line representing a pipe,

23、 etc. (irre- spective of its diameter), shall be a single continuous thick line (type A, see Table 1 and JIS Z SSlZ), coinciding with the central line of the pipe (see IS0 4067-1). Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=

24、Wing, Bernie Not for Resale, 03/15/2007 22:54:04 MDTNo reproduction or networking permitted without license from IHS -,-,- 3 B 0011-1 : 1998 (IS0 6412-1 : 1989) Continuous thin B1 Hatching B2 Dimensioning B3 Leader lines (Dimension lines, projection lines) t B4 Isometric grid lines ._._._._._. Bends

25、 may be simplified by extending the straight length of the flow line to the vertex (see Fig. 1). However, bends may be shown for sake of clarity in the form illustrated in Fig. 2 . In this case, if projections of bends would otherwise have been elliptical, these projections may be simplified by draw

26、ing circular arcs (see Fig. 3). C tus- 2cu 4 . 2 JIS 2 8314. Scale If the drawing is to scale, this shall be indicated in accordance with Continuous thin freehand CM31 Limits of partial or inter- rupted view and section !.nb,icatinis-tke- ?!?rberofa I ? * . broken .?E .Tem!.%!. ! ! O - % . Continuou

27、s thin with zigzags the object to be connected.) ._ _._._._._. 4 . 3 Lines Dashed thin Chain thin 4 . 3 . 1 Thickness of lines In general, only one thickness of line shall be used. How- ever, in cases where more than one line thickness has to be used, the line thick- nesses shall be chosen from JIS

28、Z 8312; the relative proportions of line thicknesses a : b : c shall be 2 :Jz : 1. Different line thicknesses shall then be used as follows (see also 4 . 3 . 2 ) : - line thickness a: main flow lines; - line thickness b: secondary flow lines, lettering; - line thickness c: leader lines, dimension li

29、nes, etc. F1 Floor F2 Walls F3 Ceilings F4 Holes (hole punchings) G1 Centrelines 4 . 3 . 2 Types of line The types and thicknesses of line shown in Table 1 shall be used. Table 1 Line type I Description I Application A 1 continuous thick - 1 Flow lines and connected parts I I B F Dashed thick El Flo

30、w lines specified on other drawing 1 Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/15/2007 22:54:04 MDTNo reproduction or networking permitted without license from IHS -,-,- 4 B 0011-1 : 1998 (IS

31、0 6412-1 : 1989) I Description Application Extra thick chain line (1) EJ1 Contract boundary Chain thin double-dashed K1 Outlines of adjacent parts K2 P a r t s situated in front of the cutting plane Table 1 (continued) Line type K - I N o t e (1) Four times the thickness of line type G. I 4.3.3 Spac

32、ing of lines In accordance with JI$ Z 8312, the space between paral- lel lines (including hatching) shall not be less than twice the thickness of the heavi- est of these lines, with a minimum spacing of 0.7 mm. The minimum spacing between adjacent flow lines and between flow lines and other lines sh

33、ould be 10 mm. 4.4 Lettering Lettering shall be in accordance with JIS 2 8313 (especially JIS Z 8313-1); lettering type B vertical is preferred. The line thickness of the lettering shall be the same as the line thickness of those tpd-symbols to which the lettering is close or associated (see IS0 346

34、1-2). 4.5 Dimensioning 4.5.1 In general, dimensioning shall be in accordance with JIS Z 8317. Nominal dimensions may be indicated in accordance with IS0 3545 using the short designa- tion “DN” (see Fig. 1 ) . The outer diameter (d) and the wall thickness (t) of pipes may be indicated in accordance w

35、ith JIS Z 8317 (see Fig. 2). If necessary, an item list (see IS0 7573) giving additional information on the pipes, including the associated equipment, may be added to the drawing. Lengths shall start from the outer faces of the pipe ends, flanges, or centre of the joint, whenever appropriate. Inform

36、ative reference : As for the nominal diameter of pipes, some pipes-a-c, classified by figures followed by the symbol A or B in Japanese Industrial Standards relating to piping. “DN” represents the nominal size. _._-_._-.-.-.-.- _._-_-_-.- _-_-_ .-.- ._._._-_ -_-_._. .-.-_-_._-_-_._ ._. . _-_. _ _-_-

37、._ _._-_-.- 4.5.2 Pipes with bends should be generally dimensioned from central line to cen- tral line of the pipelines (see Figs. 1 and 2 ) . If it is necessary to specify the dimension from the outside or inside external pro- tection or surface of the pipe, the dimension may be specified by arrows

38、 pointing to short thin strokes parallel to the projection line or _._.-_._.-.- flow line representing -_-_-_- -_-_. the pipe .- .-. (see Fig. 3). The dimensions from outer to outer, from inner to inner and from inner to outer vertex are shown in Figs. 3 a), 3 b) and 3 c), respectively. Copyright Ja

39、panese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/15/2007 22:54:04 MDTNo reproduction or networking permitted without license from IHS -,-,- 5 B 0011-1 : 1998 (IS0 6412-1 : 1989) I m 4.5.3 Radii and angles of be

40、nds may be indicated as shown in Fig. 4. The functional angle shall be indicated; in general, angles of 90“ are not indicated. 60.3 x 7.5 b ! Fig. 1 Fig. 2 I U a) b) Fig. 4 4.5.4 Levels refer generally to the centre of the pipe and should be indicated in accordance with IS0 129 (see Fig. 5). If, in

41、special cases, it is necessary to specify the level to the bottom of a pipe this shall be indicated by the reference arrow point- ing to short thin strokes, as specified in 4.5.2 see Fig. 3 and 8 a). A similar rule shall be applied to indicate levels to the top of the pipe see Fig. 8 c). 4.5.5 The d

42、irection of slope shall be indicated by a right angled triangle above the flow line, pointing from the higher down to the lower level. The amount of slope shall be indicated in accordance with the methods shown in Figs. 6 to 8. It may be useful to specifi the level of the sloping pipe, either at its

43、 higher or at its lower end, or at any convenient point, by referring to a datum level (see Fig. 8). Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/15/2007 22:54:04 MDTNo reproduction or networkin

44、g permitted without license from IHS -,-,- 6 B 0011-1 : 1998 (IS0 6412-1 : 1989) 4.5.6 The positions of the ends of the pipe shall be specified by indicating the coor- dinates referring to the centres of the end faces. “ h 0.2% Fig. 6 - I Fig. 5 i l . 1:SOO h 11500 4 b) Fig. 7 +3 500 +3 800 I ?+3 20

45、0 - J b) Fig. 8 4.6 Tolerances Tolerances shall be indicated in accordance with JIS Z 8318. 5 Crossings and connections 5 . 1 Crossings without connections shall normally be depicted without interrupting the flow line representing the hidden pipe (see Fig. 9; see also IS0 4067-1); if, how- ever, it

46、is absolutely necessary to indicate that one pipe has to pass behind the other, the flow line representing the hidden pipe shall be interrupted (see Fig. 10). The width of each interruption shall not be less than five times the thickness of the con- tinuous line (see Fig. 1 1 ) . + Fig. 9 * 5d min.

47、I Fig. 10 Fig. 11 Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/15/2007 22:54:04 MDTNo reproduction or networking permitted without license from IHS -,-,- STDmJIS B 0011-1-ENGL 1998 D 4933608 055b294 237 7 B 0011-1 : 1998 (IS0 6412-1 : 1989) 5.2 Permanent junctions (whether made by welding or other processes) shall be mar