1、BRITISH STANDARD Petrol filling stations Part 1: Safety requirements for construction and performance of metering pumps, dispensers and remote pumping units ICS 75.200 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW BS EN 13617-1:2004 Incorporating corrigenda July 2004 and Jan

2、uary 2006 +A1:2009 National foreword This British Standard is the UK implementation of EN 13617-1:2004+A1:2009, incorporating corrigendum January 2006. It supersedes BS EN 13617-1:2004, which is withdrawn. The start and finish of text introduced or altered by amendment is in- dicated in the text by

3、tags. Tags indicating changes to CEN text carry the number of the CEN amendment. For example, text altered by CEN amendment A1 is indicated by !“. The UK participation in its preparation was entrusted to Technical Committee PVE/21, Storage tanks for general engineering purposes. A list of organizati

4、ons represented on this committee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard cannot confer immunity from legal obligations.

5、 BS EN 13617-1:2004+A1:2009 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 11 July 2004 BSI 2009 Amendments/corrigenda issued since publication Amd. No.Date Comments 15267 Corrigendum No. 1 19 July 2004Correction to National foreword 16286 C

6、orrigendum No. 2 May 2006Revision of Annex ZA and Annex ZB 31 August 2009 Implementation of CEN amendment A1:2009 ISBN 978 0 580 63990 6 EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 13617-1:2004+A1 June 2009 ICS 75.200 Supersedes EN 13617-1:2004 English Version Petrol filling stations - Part

7、 1: Safety requirements for construction and performance of metering pumps, dispensers and remote pumping units Stations-service - Partie 1: Exigences relatives la construction et aux performances de scurit des distributeurs de carburants et units de pompage distance Tankstellen - Teil 1: Sicherheit

8、stechnische Anforderungen an Bau- und Arbeitsweise von Zapfsulen, druckversorgten Zapfsulen und Fernpumpen This European Standard was approved by CEN on 5 May 2004 and includes Corrigendum 1 issued by CEN on 25 Janvier 2006 and Amendment 1 approved by CEN on 21 May 2009. CEN members are bound to com

9、ply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Manage

10、ment Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the respons bility of a CEN member into its own language and notified to the CEN Management Centre has the same status as th

11、e official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovak

12、ia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2009 CEN All rights of exploitation in any form and by any means reserved worldwide f

13、or CEN national Members. Ref. No. EN 13617-1:2004+A1:2009: E 2 Contents page Foreword 4 1Scope 6 2Normative references 6 3Terms and definitions . 7 4List of significant hazards 11 5Safety requirements and/or protective measures 13 5.1Explosion protection measures . 13 5.2Selection of equipment . 14

14、5.3Safety requirements, protective measures, construction and performance . 21 5.4Safety requirements related to electromagnetic phenomena . 29 6Tests 30 6.1Type tests . 30 6.2Routine tests 37 7Information for use 38 7.1General 38 7.2Signals and warnings 39 7.3Accompanying documents . 39 7.4Marking

15、. 40 Annex A (normative) Classification of vapour barriers 41 A.1General 41 A.2Vapour barrier Type 1 41 A.3Vapour barrier Type 2 41 A.4Typical vapour barrier arrangements 42 Annex B (informative) Information on explosion protected equipment . 48 Annex ZA (informative) Relationship between this Europ

16、ean Standard and the Essential Requirements of EU Directive 94/9/EC 50 Annex ZB (informative) !Relationship between this European Standard and the Essential Requirements of EU Directive 98/37/EC“ . 52 Annex ZC (informative) !Relationship between this European Standard and the Essential Requirements

17、of EU Directive 2006/42/EC“ . 53 Bibliography 54 Figures Figure 1 Nozzle outside a housing at distance 50 mm and 200 mm 16 Figure 2 Nozzle outside a housing at distance 50 mm and 200 mm 17 Figure 3 Nozzle outside a housing at distance 50 mm 18 Figure 4 Nozzle boot area, front view. 19 Figure 5 Nozzl

18、e boot area, side view 20 Figure 6 Nozzle boot area, top view . 21 Figure 7 Test set-up for the impact test . 32 Figure 8 Test set-up for flame transmission test 35 Figure A.1 Horizontal vapour barrier Type 1 . 42 Figure A.2 Vertical vapour barrier Type 1 43 Figure A.3 Horizontal vapour barrier Type

19、 2 . 44 BS EN 13617-1:2004+A1:2009 EN 13617-1:2004+A1:2009 (E) 3 Figure A.4 Vertical vapour barrier Type 2 45 Figure A.5 Vertical vapour barrier Type 2 46 Figure A.6 Vertical vapour barrier Type 2 47 Tables Table 1 List of significant hazards . 12 Table 2 Test voltages . 33 Table 3 Routine electrica

20、l tests 38 Table B.1 Standard protection concepts allowed . 49 Table ZA.1 Essential requirements of Directive 94/9/EC Equipment and protective systems intended for use in potentially explosive atmospheres Annex II . 50 BS EN 13617-1:2004+A1:2009 EN 13617-1:2004+A1:2009 (E) 4 Foreword This document (

21、EN 13617-1:2004+A1:2009) has been prepared by Technical Committee CEN/TC 393 “Equipment for storage tanks and for service stations”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endo

22、rsement, at the latest by December 2009, and conflicting national standards shall be withdrawn at the latest by December 2009. This document includes Amendment 1, approved by CEN on 2009-05-21 and Corrigendum 1, issued by CEN on 25 January 2006. This document supersedes EN 13617-1:2004. The start an

23、d finish of text introduced or altered by amendment is indicated in the text by tags ! “. The modifications of the related CEN Corrigendum have been implemented at the appropriate places in the text and are indicated by the tags . This document has been prepared under a mandate given to CEN by the E

24、uropean Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). !For relationship with EU Directives, see informative Annexes ZA, ZB and ZC, which are integral parts of this document.“ This European Standard “Petrol filling stations” consists of 4

25、parts: Part 1: Safety requirements for construction and performance of metering pumps, dispensers and remote pumping units Part 2 !deleted text“ : Safety requirements for construction and performance of safe breaks for use on metering pumps and dispensers Part 3 !deleted text“ : Safety requirements

26、for construction and performance of shear valves Part 4 !deleted text“ : Safety requirements for construction and performance of swivels for use on metering pumps and dispensers Annex A is normative. Annex B is informative. According to the CEN/CENELEC Internal Regulations, the national standards or

27、ganizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,

28、 Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. BS EN 13617-1:2004+A1:2009 EN 13617-1:2004+A1:2009 (E) 5 Introduction This document is a type C standard as stated in !EN ISO 12100-1 and EN 12100-2“. The machinery concerned and the extent to which hazards, hazardous situa

29、tions and events are covered are indicated in the scope of this document. When provisions of this type C standard are different from those which are stated in type A or B standards, the provisions of this type C standard take precedence over the provisions of the other standards, for machines that h

30、ave been designed and built according to the provisions of the type C standard. It has been assumed that the use of the equipment for dispensing of fuels will be by untrained persons (user / dispenser), while other aspects of the operation, maintenance, etc, will be by designated and trained personn

31、el (station personnel or operator). BS EN 13617-1:2004+A1:2009 EN 13617-1:2004+A1:2009 (E) 6 1 Scope This European Standard applies to metering pumps, dispensers and remote pumping units to be installed at petrol filling stations, designed to dispense liquid fuels into the tanks of motor vehicles, b

32、oats and light aircraft and into portable containers at flow rates up to 200 lmin-1, and intended for use and storage at ambient temperatures between -20 C and +40 C. !Measures in addition to those required by this standard may be required for use and storage at temperature outside this range. The n

33、eed for and nature of additional requirements should be determined by the manufacturer, if necessary after consulting the client.“ This European Standard deals with all significant hazards, hazardous situations and events relevant to metering pumps, dispensers and remote pumping units, when they are

34、 used as intended and under the conditions !foreseeable“ by the manufacturer (see clause 4). !This European Standard gives health and safety related requirements for the selection, construction and performance of the equipment.“ This European Standard does not deal with noise and with hazards relate

35、d to transportation and installation. This European Standard does not include any requirements for metering performance. Vapour recovery efficiency rates are not considered within this European Standard. This European Standard is not applicable to metering pumps, dispensers and remote pumping units

36、which are manufactured before the date of publication of this document by CEN. NOTE Liquefied petroleum gas (LPG) is not a liquid fuel in the sense of this European Standard. 2 Normative references !The following referenced documents are indispensable for the application of this document. For dated

37、references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.“ EN 228, Automotive fuels Unleaded petrol Requirements and test methods !deleted text“ EN 1360, Rubber hoses and hose assemblies for measured fuel dis

38、pensing Specification EN 12874, Flame arresters Performance requirements, test methods and limits for use EN 13012, Petrol filling stations Construction and performance of automatic nozzles for use on fuel dispensers EN 13463-1:2001, Non-electrical equipment for potentially explosive atmospheres Par

39、t 1: Basic method and requirements !EN 13483“, !Rubber and plastic hoses“ and hose assemblies with internal vapour recovery for measured fuel dispensing systems Specification !deleted text“ !EN 60079-0:2006, Electrical apparatus for explosive gas atmospheres Part 0: General requirements (IEC 60079-0

40、:2004, modified) EN 60079-1:2007, Explosive atmospheres Part 1: Equipment protection by flameproof enclosures “d“ (IEC 60079-1:2007) BS EN 13617-1:2004+A1:2009 EN 13617-1:2004+A1:2009 (E) 7 EN 60079-7:2007, Explosive atmospheres Part 7: Equipment protection by increased safety “e“ (IEC 60079-7:2006)

41、“ EN 60079-10, Electrical apparatus for explosive gas atmospheres Part 10: Classification of hazardous areas !(IEC 60079-10:2002)“ EN 60079-14, Electrical apparatus for explosive gas atmospheres Part 14: Electrical installations in hazardous areas (other than mines) !(IEC 60079-14:2002)“ !EN 60079-1

42、5, Electrical apparatus for explosive gas atmospheres Part 15: Construction, test and marking of type of protection “n“ electrical apparatus (IEC 60079-15:2005)“ !EN 60204-1:2006, Safety of machinery Electrical equipment of machines Part 1: General requirements (IEC 60204-1:2005, modified)“ EN 60529

43、, Degrees for protection provided by enclosures (IP code) (IEC 60529:1989) EN 60730-2-10, Automatic electrical controls for household and similar use Part 2: Particular requirements for motor starting relays !(IEC 60730-2-10:2006)“ EN 60947-3, Low-voltage switchgear and controlgear Part 3: Switches,

44、 disconnectors, switch-disconnectors and fuse-combination units (IEC 60947-3:1999) EN 60950-1, Information technology equipment Safety Part 1: General requirements !(IEC 60950-1:2005, modified)“ EN ISO 1182, Reaction to fire tests for building products Non-combustibility test (ISO 1182:2002) EN ISO

45、12100-1:2003, Safety of machinery Basic concepts, general principles for design Part 1: Basic terminology, methodology (ISO 12100-1:2003) EN ISO 12100-2:2003, Safety of machinery Basic concepts, general principles for design Part 2: Technical principles (ISO 12100-2:2003) !EN ISO 13849-1, Safety of

46、machinery Safety-related parts of control systems Part 1: General principles for design (ISO 13849-1:2006) EN ISO 14121-1, Safety of machinery Risk assessment Part 1: Principles (ISO 14121-1:2007)“ ISO 11925-3, Reaction to fire tests Ignitability of building products subjected to direct impingement

47、of flame Part 3: Multi-source test HD21.13 S1, Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V Part 13: Oil resistant PVC sheathed cables with two or more conductors HD22.4 S3, Rubber insulated cables of rated voltages up to and including 450/750 V Part 4: Cords a

48、nd flexible cables 3 Terms and definitions For the purposes of this European Standard, the terms and definitions given in !EN ISO 12100-1“ and the following apply. 3.1 air and/or vapour separator device used for continuously separating and removing air or gases contained in the liquid 3.2 delivery h

49、ose assembly flexible delivery system to which the nozzle is connected BS EN 13617-1:2004+A1:2009 EN 13617-1:2004+A1:2009 (E) 8 3.3 column extension fabrication extending upwards from a metering pump/dispenser hydraulic housing 3.4 metering pump measuring system containing its own pumping system to draw and deliver liquid fuel from a supply tank or tanks into the tanks of motor vehicles, boats and light aircraft and into portable containers 3.