【BS英国标准】BS EN 445-1997 Grout for prestressing tEN dons -- Test methods.doc

上传人:哈尼dd 文档编号:3620355 上传时间:2019-09-18 格式:DOC 页数:18 大小:546KB
返回 下载 相关 举报
【BS英国标准】BS EN 445-1997 Grout for prestressing tEN dons -- Test methods.doc_第1页
第1页 / 共18页
【BS英国标准】BS EN 445-1997 Grout for prestressing tEN dons -- Test methods.doc_第2页
第2页 / 共18页
【BS英国标准】BS EN 445-1997 Grout for prestressing tEN dons -- Test methods.doc_第3页
第3页 / 共18页
【BS英国标准】BS EN 445-1997 Grout for prestressing tEN dons -- Test methods.doc_第4页
第4页 / 共18页
【BS英国标准】BS EN 445-1997 Grout for prestressing tEN dons -- Test methods.doc_第5页
第5页 / 共18页
亲,该文档总共18页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《【BS英国标准】BS EN 445-1997 Grout for prestressing tEN dons -- Test methods.doc》由会员分享,可在线阅读,更多相关《【BS英国标准】BS EN 445-1997 Grout for prestressing tEN dons -- Test methods.doc(18页珍藏版)》请在三一文库上搜索。

1、国内外标准大全豆丁网国内外标准下载地址 http:/ STANDARDGrout for prestressing tendons Test methodsThe European Standard EN 445 : 1996 has the status of aBritish StandardICS 91.100.10 ; 91.100.30| BS EN445 : 1997| Incorporating| Amendment No. 1|Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 04 09:25:40 GMT+00:00 20

2、06, Uncontrolled Copy, (c) BSI|NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBS EN 445 : 1997 Issue 2, December 1997Committees responsible for thisBritish StandardThe preparation of this British Standard was entrusted by Technical Committee B/525, Building and civil engineeri

3、ng structures, to Subcommittee B/525/2, Structural use of concrete, upon which the following bodies were represented:Association of Consulting EngineersBritish Cement AssociationBritish Precast Concrete Federation Ltd. Concrete SocietyDepartment of the Environment (Building Research Establishment) D

4、epartment of the Environment (Construction Sponsorship Directorate) Department of Transport (Highways Agency)Institution of Civil Engineers Institution of Structural Engineers Steel Reinforcement CommissionThis British Standard, having been prepared under the direction of the Sector Board for Buildi

5、ng and Civil Engineering, was published under the authority of the Standards Board and comes into effect on15 November 1997Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 04 09:25:40 GMT+00:00 2006, Uncontrolled Copy, (c) BSIBSI 1997The following BSI references relate to the work on this standar

6、d:Committee reference B/525/2Draft for comment 91/10645 DCISBN 0 580 28311 9Amd. No.DateText affected9876December1997Indicated by a sideline in the marginAmendments issued since publicationLicensed Copy: sheffieldun sheffieldun, na, Sat Nov 04 09:25:40 GMT+00:00 2006, Uncontrolled Copy, (c) BSIIssue

7、 2, December 1997BS EN 445 : 1997National forewordThis British Standard has been prepared by Subcommittee B/525/2 and is the English language version of EN 445 : 1996 Grout for prestressing tendons Test methods published by the European Committee for Standardization (CEN).EN 445 was produced as a re

8、sult of European discussions in which the UK took an active part. The UK voted against this standard at the CEN Formal Vote stage because UK industry considered the standard to be insufficient in providing suitable specification requirements for grouting materials and procedures, particularly for hi

9、ghway bridges.The UK conducted significant development work and subsequently published Concrete Society Technical Report No. 47 Durable Bonded Post Tensioned Concrete Bridges, prepared by a Concrete Society Working Party in collaboration with the Concrete Bridge Development Group (September 1996), t

10、o which reference may be made.At the CEN Formal Vote stage, however, the analysis of voting resulted in a positive vote and in accordance with CEN/CENELEC Internal Regulations Part 2 : Common rules for standards work EN 445 was accepted as a European Standard.Cross-referencePublication referred to C

11、orresponding British StandardEN 196-1 : 1994BS EN 196-1 : 1995 Determination of strengthTextual errorThe textual error set out below was discovered when adopting the text of theEuropean Standard. It has been reported to CEN in a proposal to amend the text of theEuropean Standard.Figure 2 in the publ

12、ished EN version is not correct. In the national annex NA (informative) of this BS EN an updated version of the figure is given until such time as the EN is amended.Compliance with a British Standard does not of itself confer immunity from legal obligations.|BSI 1997iblankiiLicensed Copy: sheffieldu

13、n sheffieldun, na, Sat Nov 04 09:25:40 GMT+00:00 2006, Uncontrolled Copy, (c) BSIEUROPEAN STANDARDEN 445NORME EUROPE ENNEEUROPA ISCHE NORMMarch 1996ICS 91.100.30Descriptors: Cables, ropes, prestressed concrete, grouting, viscosity, testsEnglish versionGrout for prestressing tendons Test methodsCouli

14、s pour ca ble de pre contrainte Me thode dessaisEinpremo rtel fu r Spannglieder Pru fverfahrenThis European Standard was approved by CEN on 1994-10-28. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the statu

15、s of a national standard without any alteration.Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A vers

16、ion in any other language made by translation under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official versions.CEN members are the national standards bodies of Austria, Belgium, Denmark, Finland, France, Germany, Gree

17、ce, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.CENEuropean Committee for Standardization Comite Europe en de Normalisation Europa isches Komitee fu r NormungCentral Secretariat: rue de Stassart 36, B-1050 BrusselsLicensed Copy: s

18、heffieldun sheffieldun, na, Sat Nov 04 09:25:40 GMT+00:00 2006, Uncontrolled Copy, (c) BSI1996 Copyright reserved to CEN members.Ref. No. EN 445 : 1996 EPage 7EN 445 : 1996Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 04 09:25:40 GMT+00:00 2006, Uncontrolled Copy, (c) BSIForewordPage3.4Volume

19、change test63.4.1Principle of test63.4.2Cylinder method63.4.2.1Apparatus63.4.2.2Procedure63.4.2.3Reporting of results63.4.3Can method63.4.3.1Apparatus63.4.3.2Procedure63.4.3.3Reporting of results63.5Compression strength test63.5.1Prisms63.5.1.1Principle of the test63.5.1.2Apparatus73.5.1.3Procedure7

20、3.5.1.3.1Moulding of the test specimens73.5.1.3.2Curing of test specimens83.5.1.3.3Compression test83.5.1.4Reporting of results83.5.2Cylinders83.5.2.1Principle83.5.2.2Apparatus83.5.2.3Procedure83.5.2.4Reporting of results8This European Standard has been prepared by Technical Committee CEN/TC 104, Co

21、ncrete Performance, production, placing and compliance criteria, the Secretariat of which is held by DIN.This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest bySeptember 1996, and conflicting national sta

22、ndards shall be withdrawn at the latest by September 1996.According to the CEN/CENELEC Internal Regulations, the following countries are bound to implement this European Standard: Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, P

23、ortugal, Spain, Sweden, Switzerland and the United Kingdom.ContentsPageForeword20Introduction31Scope32Normative references33Testing of grout33.1General conditions33.2Fluidity test33.2.1Immersion method33.2.1.1Principle of test33.2.1.2Apparatus33.2.1.3Calibration procedure33.2.1.4Test procedure33.2.1

24、.5Reporting the results53.2.2Cone method53.2.2.1Principle of test53.2.2.2Apparatus53.2.2.3Test procedure53.2.2.4Reporting of results53.3Bleeding test53.3.1Principle of test53.3.2Apparatus53.3.3Procedure53.3.4Reporting of results6BSI 1997Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 04 09:25:40

25、 GMT+00:00 2006, Uncontrolled Copy, (c) BSI0 IntroductionIn post-tensioned prestressed concrete construction,the grouting of tendons is an important operation. This European Standard provides methods of test for grout specified in EN 447. Some tests given herein are alternatives and it will be neces

26、sary to relate the chosen test method to the specified requirements.1 ScopeThis European Standard describes the methods of test for grout specified in EN 447.2 Normative referencesThis European Standard incorporates by dated or undated reference, provisions from other publications. These normative r

27、eferences are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard onlywhen incorporated in it by amendment or revision. For undated references t

28、he latest edition of the publication referred to applies.EN 196-1 : 1987 Methods of testing cement Determination of strengthEN 447Grout for prestressing tendons Specification for common groutISO 4012Concrete Determination of compressive strength of test specimens3 Testing of grout3.1 General conditi

29、onsThe grouts shall be tested by competent personnel experienced in the subject. The normal conditions of temperature and relative humidity at test shall be as follows: temperature (20 2) C; relative humidity 65 %.These conditions are for the specification of the grout. Variations in temperature and

30、 humidity on site may cause variations in the test results and shall be reported.The grout for the tests shall be made from materials specified in clause 4 of EN 447 and mixed in accordance with clause 6 of EN 447. The temperature of the freshly mixed grout is to be given in all test reports.3.2 Flu

31、idity test3.2.1 Immersion method3.2.1.1 Principle of testThe test consists of measuring the time a plunger needs to drop through a defined amount of grout in a tube.3.2.1.2 Apparatusa) Calibrated immersion equipment, according to figure 1.b) A 0,5 m spacer rod, according to figure 1. c) A stopwatch.

32、3.2.1.3 Calibration procedureCalibrate the immersion equipment with glycerol(analytical grade) having a density of 1,226 g/cm3 at(20 0,5) C. The temperature of the room, immersionequipment and glycerol shall be (20 0,5) C during the calibration.Fill the cylinder with about 1,9 l glycerol up to appro

33、ximately 260 mm below the rim. After filling the immersion equipment the glycerol shall be allowed to rest for about 1 h. Then immerse the plunger to expel the air bubbles from the glycerol, which may have been introduced into the glycerol during the filling of the cylinder.After at least 1 h positi

34、on the plunger so that its stop on the tail rod lies on the spacer placed at the top of the tube. Then pull the spacer away to allow the plunger to sink to the stop of the tube. Record this time to the nearest second.Repeat the calibration at least three times.The mean value of all measured immersio

35、n times shall be (34 1) s. If the test result deviates from this value the weight of the plunger shall be increased wheret 35 s or reduced where t 33 s. This is done by varying the quantity of the lead pellets in the plunger. Delay repeating the calibration procedure for atleast 30 min to ensure tha

36、t no air bubbles are in the glycerol resulting from the preceding calibration procedure.3.2.1.4 Test procedurePreparationThe adjustment of the immersion equipment shall be tested before it is used. Adjustment of the immersion equipment shall be tested subsequently once a year and/or after any damage

37、.Directly before the test place the equipment vertically and dampen the inside of the tube and the plunger so that the surface is moist but without free water. ProcedureFill the cylinder with approximately 1,9 l grout up to approximately 260 mm below the rim, so that the plunger is fully immersed on

38、 introduction if its stop on the tail rod lies on the spacer placed at the top of the tube. Then pull the spacer away; the plunger sinks to the stop in the tube. Then raise the plunger back to its initial position, insert the spacer, pull it away again and measure the time until the stop lies on the

39、 tube. Measure the immersion times of the grout immediately after the mixing process and after 30 min.For the test after 30 min, grout from the same mix as that used for the immersion test immediately after the mixing process shall be used; the grout is to be kept in motion with the stirrer until th

40、e carrying out of the test after 30 min. Each test is carried out three times in succession with the same filling.Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 04 09:25:40 GMT+00:00 2006, Uncontrolled Copy, (c) BSI1 Stop2 Guide rod3 Wooden rod (as spacer)4 Cu-Zn tube5 Final position of the plu

41、nger6 Level7 Wooden rod (as measuring rod)8 White dye9 Guide cam10 Grout level in the starting position of the plunger11 Grout level without plunger ( 1,9 l)Figure 1. Immersion equipment for determining the immersion time3.2.1.5 Reporting of resultsReport the result as the average of the immersion t

42、imes to the nearest second of the second and third immersion, ignoring the first immersion time.3.2.2 Cone method3.2.2.1 Principle of testThe fluidity of grout, expressed in seconds, measured by the time necessary for a stated quantity of grout to pass through the orifice of the cone, under stated c

43、onditions.3.2.2.2 ApparatusThe following apparatus is required for the test.a) Cone, a cone of the dimensions given in figure 2. It shall be robust and manufactured from materials not reactive with any materials specified in clause 4 of EN 447. The volume of the cone (excluding the cylindrical portions at top and bottom) shallbe 1,7 l10 %.b) Sieving medium, the sieving medium ape

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 其他


经营许可证编号:宁ICP备18001539号-1