【BS英国标准】BS EN 867-1-1997 Non-biological systems for use in sterilizers Part 1. General requirements.doc

上传人:椰子壳 文档编号:3620821 上传时间:2019-09-18 格式:DOC 页数:13 大小:330KB
返回 下载 相关 举报
【BS英国标准】BS EN 867-1-1997 Non-biological systems for use in sterilizers Part 1. General requirements.doc_第1页
第1页 / 共13页
【BS英国标准】BS EN 867-1-1997 Non-biological systems for use in sterilizers Part 1. General requirements.doc_第2页
第2页 / 共13页
【BS英国标准】BS EN 867-1-1997 Non-biological systems for use in sterilizers Part 1. General requirements.doc_第3页
第3页 / 共13页
【BS英国标准】BS EN 867-1-1997 Non-biological systems for use in sterilizers Part 1. General requirements.doc_第4页
第4页 / 共13页
【BS英国标准】BS EN 867-1-1997 Non-biological systems for use in sterilizers Part 1. General requirements.doc_第5页
第5页 / 共13页
亲,该文档总共13页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《【BS英国标准】BS EN 867-1-1997 Non-biological systems for use in sterilizers Part 1. General requirements.doc》由会员分享,可在线阅读,更多相关《【BS英国标准】BS EN 867-1-1997 Non-biological systems for use in sterilizers Part 1. General requirements.doc(13页珍藏版)》请在三一文库上搜索。

1、BRITISH STANDARDNon-biological systems for use in sterilizersPart 1. General requirementsThe European Standard EN 867-1 : 1997 has the status of aBritish StandardICS 11.080| BS EN867-1 : 1997|NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBS EN 867-1 : 1997Committees responsib

2、le for thisBritish StandardThe preparation of this British Standard was entrusted by Technical Committee LBI/35, Sterilizers, autoclaves and disinfectors, to Subcommittee LBI/35/3, Sterilization indicators, upon which the following bodies were represented:ABHI Special Interest Section (Sterilizers a

3、nd Disinfectors) Association of British Healthcare IndustriesBLWA Ltd. (the Association of the Laboratory Supply Industry) Department of Health (Medical Devices Agency)European Sterilization Packaging Association (UK) Medical Sterile Products AssociationPublic Health Laboratory ServiceRoyal College

4、of PathologistsRoyal Pharmaceutical Society of Great BritainThis British Standard, having been prepared under the direction of the Sector Board for Materials and Chemicals, was published under the authority of the Standards Board and comes into effect on15 October 1997BSI 1997The following BSI refer

5、ences relate to the work on this standard:Committee reference LBI/35/3Draft for comment 92/57874 DCISBN 0 580 28130 2Amd. No.DateText affectedAmendments issued since publicationBS EN 867-1 : 1997National forewordThis Part of BS EN 867 has been prepared by Subcommittee LBI/35/3, and is the English la

6、nguage version of EN 867-1 : 1997 Non-biological systems for use in sterilizers Part 1: General requirements, published by the European Committee for Standardization (CEN).Cross-referencePublication referred to Corresponding British StandardEN 28601BS EN 28601 : 1992 Specification for representation

7、 of dates and times in information interchangeAttention is also drawn to BS 7720 : 1995 Specification for non-biological sterilization indicators equivalent to the Bowie and Dick test.Compliance with a British Standard does not of itself confer immunity from legal obligations.Summary of pagesThis do

8、cument comprises a front cover, an inside front cover, pages i and ii, theEN title page, pages 2 to 6, an inside back cover and a back cover.BSI 1997iiiblankEUROPEAN STANDARDEN 867-1NORME EUROPE ENNEEUROPA ISCHE NORMFebruary 1997ICS 11.080Descriptors: Medical equipment, sterilizers, tests, steriliza

9、tion, chemical indicators, classifications, specifications, labellingEnglish versionNon-biological systems for use in sterilizers Part 1: General requirementsSyste mes non-biologiques destine s a e tre utilise s dans des ste rilisateurs Partie 1: Exigences ge ne ralesNichtbiologische Systeme fu r en

10、 Gebrauch inSterilisatoren Teil 1: Allgemeine AnforderungenThis European Standard was approved by CEN on 1997-01-10. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without an

11、y alteration.Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CEN member.The European Standards exist in three official versions (English, French, German). A version in any other language made by tr

12、anslation under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official versions.CEN members are the national standards bodies of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembo

13、urg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.CENEuropean Committee for Standardization Comite Europe en de Normalisation Europa isches Komitee fu r NormungCentral Secretariat: rue de Stassart 36, B-1050 Brussels1997 Copyright reserved to CEN membersRef. No. EN 86

14、7-1 : 1997 EPage 5EN 867-1 : 1997BSI 1997ForewordThis European Standard has been prepared by Technical Committee CEN/TC 102, Sterilizers for medical purposes, the secretariat of which is held by DIN.This standard is one of a series of European Standards concerned with non-biological systems for test

15、ing sterilizers. These standards are:EN 867-1Non-biological systems for use in sterilizers Part 1: General requirementsEN 867-2Non-biological systems for use in sterilizers Part 2: Process indicators (Class A)EN 867-3Non-biological systems for use in sterilizers Part 3: Specification for Class B ind

16、icators for use in the Bowie and Dick testIn addition, CEN/TC 102 Working Group 7 has prepared a series of European Standards describing biological indicators for use in sterilizers. These European Standards are:EN 866-1Biological systems for testing sterilizers and sterilization processes Part 1: G

17、eneral requirementsEN 866-2Biological systems for testing sterilizers and sterilization processes Part 2: Particular systems for use in ethylene oxide sterilizersEN 866-3Biological systems for testing sterilizers and sterilization processes Part 3: Particular systems for use in moist heat sterilizer

18、sprEN 866-4Biological systems for testing sterilizers and sterilization processes Part 4: Particular systems for use in irradiation sterilizersprEN 866-5Biological systems for testing sterilizers and sterilization processes Part 5: Particular systems for use in low temperature steam and formaldehyde

19、 sterilizersprEN 866-6Biological systems for testing sterilizers and sterilization processes Part 6: Particular systems for use in dry heat sterilizersprEN 866-7Biological systems for testing sterilizers and sterilization processes Part 7: Particular requirements for self-contained biological indica

20、tor systems for use in moist heat sterilizersprEN 866-8Biological systems for testing sterilizers and sterilization processes Part 8: Particular requirements for self-contained biological systems for use in ethylene oxide sterilizersThis European Standard shall be given the status of a national stan

21、dard, either by publication of an identical text or by endorsement, at the latest by August 1997, and conflicting national standards shall be withdrawn at the latest by August 1997.This European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free

22、Trade Association, and supports essential reuirements of EU Directive(s).According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Denmark, Finland, France, Germany, Greece, Icel

23、and, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and the United Kingdom.ContentsPageForeword 2Introduction 31 Scope 32 Normative references 33 Definitions 34 Classification 45 General requirements 46 Labelling and instructions for use 5Annex A (informative)

24、Bibliography 6IntroductionEuropean Standards for sterilizers (EN 285 and other standards in preparation by CEN/TC 102) and for the validation and process control of sterilization (EN 550, EN 552 and EN 554) describe performance tests for sterilizers and methods of validation and routine control, res

25、pectively.This standard specifies the general requirements for non-biological indicators and subsequent parts specify the particular requirements for non-biological indicators for particular applications and for defined tests of particular sterilization processes. The use of the indicators specified

26、 in this standard are described in EN 285, EN 550, EN 552 and EN 554.The non-biological indicators specified in this standard are not intended for use in any process other than that specified. The use of an inappropriate indicator can give dangerously misleading results.The performance of a non-biol

27、ogical indicator can be affected by the conditions of storage prior to use, the methods of use, and the conditions of storage after exposure to the process. For these reasons, the recommendations of the manufacturer for storage and use should be followed precisely. Non-biological indicators should n

28、ot be used beyond any expiry date stated by the manufacturer.When a physical and/or chemical variable of a sterilizing process is outside its specified limits, a sterilization cycle should always be regarded as unsatisfactory, irrespective of the results obtained from the non-biological indicators.1

29、 ScopeThis European Standard specifies general requirements for indicators which are not dependent for their action on the presence or absence of living organisms, and which are used to monitor the presence or attainment of one or more of the variables required for a satisfactory sterilization proce

30、ss.This standard does not specify requirements for the use of biological systems.NOTE. Biological test systems are regarded as those tests which are dependent for their interpretation on the demonstration of viability of an organism. Test systems of this type are considered in EN 866 Biological syst

31、ems for testing sterilizers and sterilization processes.The requirements of this part of EN 867 apply to all indicator systems specified in subsequent parts ofEN 867, unless the requirement is modified or added to by a subsequent part, in which case the requirement of the particular part will apply.

32、2 Normative referencesThis European Standard incorporates by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisio

33、ns of any of these publications apply to this European Standard onlywhen incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies.EN 28601Data elements and interchangeformats Information interchange Representation of dates and time

34、s(ISO 8601 : 1988 and technical corrigendum 1 : 1991)3 DefinitionsFor the purposes of this European Standard the following definitions apply:3.1 graduated responseA progressive visible change occurring on exposure to one or more process variables allowing assessment of the level achieved.3.2 defined

35、 end-pointThe visible change occurring after exposure to the specified variable(s) at a level equal to or greater than that specified for the indicator.3.3 indicatorThe indicator system in the form in which it is intended to be used.3.4 indicator reagentThe active ingredient or combination of ingred

36、ients before conversion into the indicator.3.5 indicator systemThe combination of the indicator reagent and its substrate.4 ClassificationNOTE. In the subsequent parts of this standard indicators are classified by their intended use and, within each of these classifications, by the process for which

37、 they are designed to be used.4.1 Process indicators Class AProcess indicators are intended for use with individual packs of product intended to be sterilized to demonstrate that the pack has been exposed to the process. They may be designed to react to one or more of the critical process variables

38、but may be designed to achieve their end-point reaction after exposure tosub-optimal levels of the process variable.Process indicators have a defined end-point reaction.4.2 Indicators for use in specific tests Class BThese indicators are designed for use in a specific test procedure defined in the r

39、elevant sterilizer/sterilization standard.These indicators may have a graduated response or a defined end-point reaction.4.3 Single-variable indicators Class CSingle-variable indicators are designed to monitor the attainment of the required value of one critical variable in the sterilization process

40、.Single-variable indicators may have a graduated response or a defined end-point reaction.4.4 Multi-variable indicators Class DMulti-variable indicators are designed to monitor the attainment of the required value of two or more critical variables in the sterilization process.Multi-variable indicato

41、rs may have a graduated response or a defined end-point reaction.5 General requirements5.1 General5.1.1 The requirements of this section shall apply to all indicators unless specifically excluded or amended in a subsequent part of this standard.5.1.2 The manufacturer shall establish, document and ma

42、intain a formal quality system to cover alloperations required by this standard.NOTE. EN ISO 9001 and EN ISO 9002 and of the EN 45000 series describe requirements for quality systems for manufacture and testing.5.2 LabellingWhere a date is required on labelling or information supplied with the produ

43、ct, this shall be expressed in accordance with EN 28601.5.3 Test methodsThe test methods specified in this standard are reference methods. When alternative methods are used routinely these shall be defined, validated and have known correlation with the reference method.5.4 Marking5.4.1 Each indicato

44、r shall be clearly marked with the type of process for which it is intended to be used and the class of indicator as defined in this standard(see 4.1 to 4.4 inclusive).If the use of the indicator is limited to specific sterilization cycles, this information shall also be stated or coded on the indicator, e.g. steam 15 min 121 C.Where the size