1、 ANSI/BHMA A156.12 2005 Revision of A156.12 1999 AMERICAN NATIONAL STANDARD FOR INTERCONNECTED LOCKS SPONSOR BUILDERS HARDWARE MANUFACTURERS ASSOCIATION, INC. ANSI Approved November, 16, 2005 AMERICAN NATIONAL STANDARDS INSTITUTE, INC. 2 AMERICAN NATIONAL STANDARD An American National Standard impli

2、es a consensus of those substantially concerned with its scope and provisions. An American National Standard is intended as a guide to aid the manufacturer, the consumer and the general public. The existence of an American National Standard does not in any respect preclude anyone, whether he has app

3、roved the standard or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standard. American National Standards are subject to periodic review and users are cautioned to obtain the latest editions. CAUTION NOTICE: This American National S

4、tandard is permitted to be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken to reaffirm, revise, or withdraw this standard no later than five years from the date of publication. Purchasers of American National Standards receiv

5、e current information on all standards by calling or writing the American National Standards Institute. Published by BUILDERS HARDWARE MANUFACTURERS ASSOCIATION, INC. 355 Lexington Avenue, New York, New York, 10017 Copyright 2005 by the Builders Hardware Manufacturers Association, Inc. Not to be rep

6、roduced without specific authorization from BHMA Printed in the USA This Standard was approved by ANSI under the Canvass Method. BHMA was accredited on 21 March 1983 by ANSI as a sponsor using the Canvass Method. -,-,- 3 FOREWORD (This Foreword is not a part of ANSI/BHMA A156.12) The general classif

7、ication of builders hardware includes a wide variety of items which are divided into several categories. To recognize this diversity, a sectional classification system has been established. Interconnected Locks is one such section and this Standard is a result of the collective efforts of members of

8、 the Builders Hardware Manufacturers Association, Inc. who manufacture this product. The total Product Standards effort is, therefore, a collection of sections, each covering a specific category of items. Performance tests and, where necessary, material and dimensional requirements have been establi

9、shed to insure safety and stability to which the public is entitled. There are no restrictions on design except for those dimensional requirements imposed for reasons given above. This Standard is not intended to obstruct but rather to encourage the development of improved products, methods and mate

10、rials. The BHMA recognizes that errors will be found, items will become obsolete, and new products, methods and materials will be developed. With this in mind, the Association plans to update, correct and revise these Standards on a regular basis. In most cases, products have been described in grade

11、 levels related to performance. Choice of grade and specific product are to be made on the basis of utility, aesthetics, security objectives and end use desired. The BHMA numbers which indicate functions of interconnected locks do not identify grade, finish, or design and are not intended to be used

12、 without necessary supplementary information. Individual manufacturers catalogs are consulted. Users of this Standard consult applicable local building codes as to requirements affecting the functions of locks used on fire doors and doors within a mean of egress. Some communities require use of exte

13、rior door locks having a dead bolt with a 1 in. (25.4 mm) projection for the purpose of providing greater security. Only functions compatible with the requirements of the applicable building codes are used. ORDERING INFORMATION BHMA standards, publications, and matchplates can be ordered at: - Sear

14、ch entire catalog, order printed or electronic versions, and download electronic versions right to your computer. Call our Fulfillment Partner, Techstreet, at: Toll-free (800) 699-9277 (U.S. and Canada) Ph. (734) 913-3930 Fax (734) 913-3946 E-mail: Send mail to: BHMA c/o Techstreet 777 E. Eisenhowe

15、r Parkway Ann Arbor, MI 48108 USA -,-,- 4 TABLE OF CONTENTS 1. SCOPE.5 2. DEFINITIONS5 3. GENERAL6 4. DIMENSIONAL CHARACTERISTICS .7 5. DESCRIPTION AND FUNCTION NUMBERS OF SERIES 5000 INTERCONNECTED LOCKS.7 6. GENERAL TEST PARAMETERS9 7 OPERATIONAL TESTS13 8. STRENGTH TESTS 16 9. CYCLE TESTS.19 10.

16、SECURITY TESTS21 11 FINISH TESTS25 APPENDIX A USERS GUIDE (NOT A PART OF ANSI/BHMA A156.12)26 5 1. SCOPE 1.1 This Standard establishes performance requirements for Interconnected Locks and includes operational tests, strength tests, security tests, cycle tests, finish tests and dimensional criteria.

17、 1.2 Tests described in this Standard are performed under laboratory conditions. In actual usage, results vary because of installation, door and frame construction, maintenance and environmental conditions. 1.3 When interconnected locks are used in fire door assemblies, they shall have been tested a

18、nd listed for use in fire doors by a Nationally Recognized Independent Testing laboratory and shall be under an in- plant follow-up inspection service. 1.4 Grade Qualifications (Also See Appendix A.) Manufacturers shall indicate the Grade level of their locks. Locks shall meet all tests for their gr

19、ade listing. A Grade 1 lock shall meet all Grade 1 criteria, a Grade 2 lock shall meet all Grade 2 criteria, and a Grade 3 lock shall meet all Grade 3 criteria in each classification. 2. DEFINITIONS 2.1 Backset The distance from the edge of the door measured at the centerline of the door thickness t

20、o the cross bore at the center. 2.2 Bolts 2.2.1 Dead Bolt A lock component having an end, which protrudes from, or is withdrawn into, the lock front by action of the lock mechanism. When the door is closed and the dead bolt thrown, it extends into a hole provided in the strike, locks the door, and d

21、oes not retract with end pressure. 2.2.2 Latch Bolt A lock component having a beveled end which projects from the lock front in its extended position, but is forced back into the lock case by end pressure or drawn back by action of the lock mechanism. When the door is closed, the latch bolt projects

22、 into a hole provided in the strike, and holds the door in a closed position. 2.2.3 Dead Locking Latch Bolt A type latch bolt incorporating a plunger which, when depressed, automatically locks the projected latch bolt against return by end pressure. Also called dead latch. 2.2.4 Deadlocking Latchbol

23、t Plunger A component of the latch bolt which, when actuated, automatically locks a projected latch bolt against return by end pressure. 2.3 Cylinders 2.3.1 Cylinder The subassembly of a lock containing a plug with a keyway and cylinder body with tumbler mechanism. 2.3.2 Cylinder Body The portion of

24、 a cylinder that surrounds the plug and contains the tumbler mechanism. 2.3.3 Cylinder Plug A component of the cylinder within the body which is actuated when the correct key is inserted. 2.3.4 Interchangeable Core Cylinder A cylinder that is removable from the lock with a designated key without dis

25、assembly of the lock. 2.3.5 Cylinder Guard That portion that surrounds the otherwise exposed portion of a cylinder to protect the cylinder from wrenching, cutting, pulling or prying. 2.3.6 Cylinder Housing The portion of a lock that surrounds and retains the cylinder body. It is often part of a lock

26、 case. -,-,- 6 2.4 Interconnected Lock A mechanically interconnected locking mechanism having a separate latch bolt or dead locking latch bolt and dead bolt designed for installation in round bored openings in the edge and face of a door. A single operation retracts all bolts. 2.5 Key A properly com

27、binated device specifically intended to operate a corresponding cylinder . 2.6 Locked Locked is when the dead locking latch bolt or dead bolt or both cannot be retracted by operating the outside lever or knob. 2.7 Lock Front A plate fastened to the edge of a door through which the bolt(s) pass. 2.8

28、Loiding Insertion of a piece of celluloid or other shim material between the door and the jamb at the latch bolt location to attempt forcible retraction of the latch bolt. 2.9 Recessed Cylinder A cylinder wherein the cylinder housing face is flush with, or recessed below, the outside surface of the

29、trim to protect the cylinder from wrenching, cutting, pulling or prying. 2.10 Strike A mortised or surface mounted plate fastened to the door frame into which the bolts project. 2.11 Strike Box A housing used in back of a strike to enclose the bolt or bolt openings. 2.12 Tailpiece A bar projecting f

30、rom the back of a rim, bored lock cylinder or a push button mechanism engaging the lock mechanism and when rotated by the key or turn either locks or unlocks the lock. 2.13 Turn The component that projects or retracts a dead bolt or latch bolt by turning. Sometimes called a turnpiece or thumbturn. 2

31、.14 Thumbpiece A lever, projecting from a handle, pressed by the thumb to retract a latch bolt. 3. GENERAL 3.1 Cylinders Cylinders supplied or mated with interconnected locks shall meet the performance requirements for the appropriate cylinder types and grade level found in the ANSI/BHMA Standard A1

32、56.5-2001 for Auxiliary Locks and Associated Products for the lock to retain their grade listing. Assemblies take the grade level of the lowest graded component. Other mechanisms are permitted to be used in lieu of cylinders providing the performance and security criteria are equivalent to that of c

33、ylinders. 3.2 Tolerances All values which do not carry specific tolerances or are not marked maximum or minimum shall have the following tolerances: Linear dimensions shall be 1/16 in (1.6 mm). Pounds or pound force shall be 2%. Degrees shall be 2 degrees. Where only minus tolerances are given, the

34、dimensions are permitted to be exceeded at the option of the manufacturers. 3.3 Door Preparation Interconnected locks and latches shall fit the door and frame preparation as specified by the individual lock manufacturer. Roses, escutcheons, knobs, levers, turns, cylinder guards shall cover all door

35、preparation openings. (See appendix note A7 for more information.) 3.4 Operating Trim Where levers are referenced, knobs, or handlesets are permitted to be used except for tests which apply to specific trim. 7 3.5 Reference to Other Standards The following Standards are referenced within: ASTM F476

36、R1996, Security Tests for Swinging Door Assemblies; ANSI/BHMA Standard A156.5-2001 for Auxiliary Locks and Associated Products, ANSI/BHMA Standard A156.2-2003 for Bored Locks, ANSI/BHMA Standard A156.13-2001 for Mortise Locks, ANSI/BHMA Standard A156.18-2000 for Materials and Finishes. ANSI Standard

37、s are available from BHMA, . ASTM Standards are available from ASTM, 100 Barr Harbor Dr., West Conshohocken, PA 19428-2959. 3.6 Values Required values in this Standard are given in U.S. units. The SI (metric) equivalents are approximate. 3.7 Deadlocking When any function of a lock combines a dead bo

38、lt and deadlocking latch bolt, the dead locking latch shall be effective whether or not the dead bolt is projected. 4. DIMENSIONAL CHARACTERISTICS 4.1 Door thickness: 1 3/8 in. and 1 3/4 in. (35 mm and 44 mm) 4.2 Backset: 1/64 in. (0.4 mm) 2 3/8 in. or 2 3/4 in. (60 mm or 70 mm) 4.3 Latch bolt/dead

39、locking latch bolt throw: -1/16 in. (1.6 mm) tolerance: 1/2 in. (12.7 mm) 4.4 Dead bolt throw: -1/16 in. (1.6 mm) tolerance: 1 in. (25.4 mm) 4.5 Turn Length: 1 3/16 in. (30 mm) minimum overall. 4.6 Knob diameter: 1 13/16 in. (46 mm) minimum 5. DESCRIPTION AND FUNCTION NUMBERS OF SERIES 5000 INTERCON

40、NECTED LOCKS F95 Entry Lock Latch bolt operated by lever from either side. Rotating turn from inside or key from outside extends dead bolt to locked position. Both dead bolt and latch bolt are retracted to unlocked position by operating inside lever. F96 Entry Lock Deadlocking latch bolt is operated

41、 by lever from either side except when outside lever is made inoperable by locking device inside. When outside lever is locked, deadlocking latch bolt is operated by key outside restoring inside locking devices to unlocked position. Rotating turn from inside or key from outside extends dead bolt to

42、locked position. Operating inside lever retracts both dead bolt and latch bolt. Closing door shall not release locking device inside. -,-,- 8 F97 Entry Lock Deadlocking latch bolt is operated by lever from either side except when outside lever is made inoperable by locking device inside.When outside

43、 lever is locked, deadlocking latch bolt is operated by key outside. Inside locking device is manually operated to unlock outside lever. Rotating turn from inside or key from outside extends dead bolt to locked position. Operating inside lever retracts both dead bolt and latch bolt. Closing door sha

44、ll not release locking device inside. F98 Storeroom Lock Key in upper cylinder projects or retracts dead bolt. Inside lever retracts both dead bolt and latch bolt. Deadlocking latch bolt is operated by key in lever outside or by operating inside lever. Outside lever always inoperable. At the option

45、of the individual manufacturer, operating the key in the outside lever shall permit the latch bolt to be retracted by operating the outside lever, providing the key cannot be removed in the unlocked position. F99 Dormitory Lock Deadlocking latch bolt is operated by lever from either side except when

46、 outside lever is made inoperable by locking device inside. When outside lever is locked, deadlocking latch bolt is operated by key outside, restoring inside locking device to unlocked position. Operating inside lever retracts both dead bolt and latch bolt. Closing door releases locking device insid

47、e. F100 Hotel Motel Lock Deadlocking latch bolt is operated by key outside or operating inside lever. Outside lever is always inoperable. Rotating turn from inside or key from outside shall extend dead bolt to locked position. Both dead bolt and deadlocking latch bolt are permitted to be retracted i

48、ndividually by key outside. Operating inside lever retracts both dead bolt and latch bolt. A visual occupancy indicator shall be operated from inside and shut out all keys in lever or knob except an emergency key. Operating inside lever shall release indicator and shut out feature unless fixed in a

49、shut out position by a special tool. F102 Handle Set Trim Thumbpiece on outside and lever on inside retracts latch. Rotating turn from inside or key from outside extends dead bolt to locked position. Both dead bolt and latch bolt are retracted to unlocked position by operating inside lever. F103 Handle Set