1、BRITISH STANDARD BS EN 13443-2:2005 Water conditioning equipment inside buildings Mechanical filters Part 2: Particle rating 1 4 4m to less than 80 4 4m Requirements for performance, safety and testing The European Standard EN 13443-2:2005 has the status of a British Standard ICS 13.060.20; 91.140.6

2、0 ? Licensed Copy: sheffieldun sheffieldun, na, Sun Oct 29 09:10:18 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 13443-2:2005 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 27 February 2006 BSI 27 February 2006 ISBN 0 580 47863 7 Nationa

3、l foreword This British Standard is the official English language version of EN 13443-2:2005. The UK participation in its preparation was entrusted by Technical Committee B/504, Water supply, to Subcommittee B/504/13, Water treatment devices, which has the responsibility to: A list of organizations

4、represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondenc

5、e Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itsel

6、f confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep UK interests informed; monitor related international and European developments and promul

7、gate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 53 and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. DateCom

8、ments Licensed Copy: sheffieldun sheffieldun, na, Sun Oct 29 09:10:18 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 13443-2 February 2005 ICS 13.060.20; 91.140.60 English version Water conditioning equipment inside buildings - Mechanical filters - Pa

9、rt 2: Particle rating 1 m to less than 80 m - Requirements for performance, safety and testing quipement de conditionnement deau lintrieur des btiments - Filtres mcaniques - Partie 2: Particules de taille 1 m 80 m; Exigences de performances, de scurit et dessais Anlagen zur Behandlung von Trinkwasse

10、r innerhalb von Gebuden - Mechanisch wirkende Filter - Teil 2: Filterfeinheit 1 m bis unter 80 m - Anforderungen an Ausfhrung, Sicherheit und Prfung This European Standard was approved by CEN on 24 December 2004. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipula

11、te the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CEN member. This European Standard exis

12、ts in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official versions. CEN members are the national standards bod

13、ies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FO

14、R STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: rue de Stassart, 36 B-1050 Brussels 2005 CENAll rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13443-2:2005: E Licensed Copy: sheffieldun s

15、heffieldun, na, Sun Oct 29 09:10:18 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 13443-2:2005 (E) 2 Contents Page Foreword3 1 Scope 4 2 Normative references4 3 Terms and definitions .4 4 Symbols and abbreviations8 5 Design requirements.9 6 Performance requirements.10 7 Test procedures.11 8 Technica

16、l documents, labelling and marking.38 Annex A (informative) Typical test reports.40 Annex B (informative) Typical graphical representation of test results46 Annex C (normative) Integrity inspection and measurement of first bubble point 50 Bibliography53 Licensed Copy: sheffieldun sheffieldun, na, Su

17、n Oct 29 09:10:18 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 13443-2:2005 (E) 3 Foreword This document (EN 13443-2:2005) has been prepared by Technical Committee CEN/TC 164 “Water supply”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national st

18、andard, either by publication of an identical text or by endorsement, at the latest by August 2005, and conflicting national standards shall be withdrawn at the latest by August 2005. a) this document provides no information as to whether the product may be used without restriction in any of the Mem

19、ber States. b) it should be noted that, while awaiting the adoption of verifiable European criteria, existing national regulation concerning the use and/or the characteristics of this product remain in force. This is the second part of the two-part standard for mechanical filters. Part 1 is concerne

20、d with mechanical filters with a particle size rating from 80 m to 150 m. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finl

21、and, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. Licensed Copy: sheffieldun sheffieldun, na, Sun Oct 29 09:10:18 GMT+00:00 2006, Uncontrolled

22、 Copy, (c) BSI EN 13443-2:2005 (E) 4 1 Scope This document specifies requirements relating to the construction, performance and methods of testing for mechanical filters for the removal of suspended matter in drinking water installations inside buildings. It applies to filters with a filtration rati

23、ng from 1 m up to less than 80 m and which are intended for use in systems with a minimum pressure rating of PN 6, connections between DN 15 and DN 100 and service temperature of less than 30 C. This document is applicable to back-washable filters, integral filters and those designed for replaceable

24、 cartridges. It only concerns units that are permanently connected to the mains supply at point of entry or point of use. Part 1 of this standard (EN 13443-1) is a separate document and deals with filters with a particle rating between 80 m and 150 m. 2 Normative references The following referenced

25、documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 872, Water quality Determination of suspended solids Method by filtrati

26、on through glass fibre filters EN 1717, Protection against pollution of potable water in water installations and general requirements of devices to prevent pollution by backflow EN 13443-1:2002, Water conditioning equipment inside buildings Mechanical filters Part 1: Particle rating 80 m to 150 m Re

27、quirements for performances, safety and testing ISO 304, Surface active agents Determination of surface tension by drawing up liquid films ISO 1219-1, Fluid power systems and components Graphic symbols and circuit diagrams Part 1: Graphic symbols ISO 4021, Hydraulic fluid power Particulate contamina

28、tion analysis Extraction of fluid samples from lines of an operating system ISO 12103-1, Road vehicles Test dust for filter evaluation Part 1: Arizona test dust 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 average pore diameter (DMP) value

29、, in m, of the pore diameter which corresponds to the mode of the relative frequency of pore diameter distribution of a filter media determined by air porosimetry 3.2 backwashable filter filter unit which is equipped with facilities, manual or automatic, to enable the periodic, in situ cleaning of t

30、he filter element by reversing the flow of water through the element 3.3 bubble point lowest air pressure at which a stream of bubbles appears at a point of the filter media surface when immersed under air pressure in a wetting liquid in accordance with Annex C Licensed Copy: sheffieldun sheffieldun

31、, na, Sun Oct 29 09:10:18 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 13443-2:2005 (E) 5 3.4 cartridge filter filter unit comprising a housing and replaceable element 3.5 collapse pressure ( Pc) 80 % of the differential pressure at the inflexion point 3.6 counting threshold electronic threshold fo

32、r detecting particles of a given size 3.7 cumulative mean filtration efficiency per period (Edp) cumulative efficiency calculated from the total numbers of particles greater than size d counted upstream and downstream of a filter during the period p 3.8 cumulative overall mean filtration efficiency

33、(Edg) cumulative efficiency calculated from the total number of particles greater than size d counted upstream and downstream of a filter during the whole test 3.9 depth filter filter element, comprising a thick porous barrier, with a pore size larger than the particles to be removed, such that the

34、particles are trapped mainly within the depth of the element as water passes through it 3.10 differential pressure (dP) pressure difference between the inlet and outlet of the filter unit measured under predetermined conditions. The differential pressure generated by the complete filter is equal to

35、the sum of the differential pressures generated by the housing and by the filter element 3.11 differential pressure at the inflexion point (dPi ) differential pressure across the filter unit including the cartridge at the inflexion point, minus the differential pressure generated by the test contain

36、er alone (see Figure B.4) 3.12 drinking water water intended for human consumption as defined by Council Directive 98/83/EC (see 1) 3.13 fibre particle which is larger than 50 m and for which the ratio of length to width is at least 10 3.14 filter cartridge replaceable filter element (spun, wound, p

37、leated, .) 3.15 filter element that part of a mechanical filter designed to retain particulate matter 3.16 filter housing pressure vessel which contains and seals the filter element and usually comprises the head, which usually embodies the connection, and the sump or body, which contains the elemen

38、t Licensed Copy: sheffieldun sheffieldun, na, Sun Oct 29 09:10:18 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 13443-2:2005 (E) 6 3.17 filter system complete installation comprising the filter housing, isolation valves, pressure gauges, pipework, etc. 3.18 final differential pressure (dPF) differen

39、tial pressure of the filter element at the end of testing 3.19 inflexion point point of discontinuity on a graph of pressure drop against solids loading curve, indicating deformation of the cartridge and potential solids break-through (see Figure B.4) 3.20 integral filter complete filter for which t

40、he filter element and housing are inseparable 3.21 ISO Coarse Test Dust (ISO CTD) siliceous test powder having a particle size distribution by convention between 0 m and 200 m in accordance with ISO 12103-1 NOTE It may also be referred to as ISO 12103-1 A4 dust. 3.22 ISO Medium Test Dust (ISO MTD) s

41、iliceous test powder having a particle size distribution by convention between 0 m and 80 m in accordance with ISO 12103-1 NOTE It may also be referred to as ISO 12103-1 A3 dust. 3.23 mechanical filter appliance designed to remove particulate matter from water by passage of the water through a porou

42、s medium 3.24 net differential pressure (dPN) difference between the final differential pressure of the clogged filter element and the differential pressure across the clean filter element (see 3.8) 3.25 nominal flow rate flow rate for the filter specified by the manufacturer or, in the absence of t

43、his specification, the flow rate through the clean filter element at which the pressure drop across the filter element is 20 kPa 3.26 particle shedding release of particles of the filter element construction material into the filtered water 3.27 reference filtration rating (S) dimension, in m , of t

44、he ISO MTD or ISO CTD particles at which the overall mean cumulative filtration efficiency of a filtering cartridge tested in accordance with the procedure described in this document, is greater than or equal to 99,8 % 3.28 retention capacity (CR) mass of ISO MTD or ISO CTD effectively retained by t

45、he filter element when the final standard differential pressure of 250 kPa is reached (CR250) or a specific one of x kPa (CRx), calculated by subtraction of the mass of contaminant in the filtrate from the injected mass Licensed Copy: sheffieldun sheffieldun, na, Sun Oct 29 09:10:18 GMT+00:00 2006,

46、Uncontrolled Copy, (c) BSI EN 13443-2:2005 (E) 7 3.29 surface filter filter element comprising a thin permeable material, with a pore size smaller than the particles to be removed, such that the particles are trapped mainly on the surface of the material as the water passes through it 3.30 total mas

47、s of injected contaminant (Mi) mass of ISO MTD or ISO CTD injected into the test circuit up to the point when the specified final differential pressure is reached Licensed Copy: sheffieldun sheffieldun, na, Sun Oct 29 09:10:18 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 13443-2:2005 (E) 8 4 Symbol

48、s and abbreviations The generic symbols and abbreviations used in this document are given in Table 1. Table 1 Symbols and abbreviations Symbol or abbreviation Parameter Unit Ce Test concentration mg/l Ci Injection concentration mg/l CR2 500 Retention capacity at 2 500 kPa g CRx Retention capacity at

49、 x kPa g CTD Coarse Test Dust - P Differential pressure kPa PF Final differential pressure kPa d Size of the particle m dPc Loss of pressure due to the test housing alone kPa dPeo Loss of pressure due to the clean filter alone kPa dPF Loss of pressure at the end of the test kPa dPi Loss of pressure at the point of inflexion kPa dPo Loss of pressure due to the test housing kPa dPs Loss of specific pressure kPa Ed Cumulative filt