1、BRITISH STANDARD BS EN 61300-2-49: 2007 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-49: Tests Connector installation test The European Standard EN 61300-2-49:2007 has the status of a British Standard ICS 33.180.20 ? Licensed Copy: London So

2、uth Bank University, London South Bank University, Sat Sep 01 03:19:42 GMT+00:00 2007, Uncontrolled Copy, (c) BSI BS EN 61300-2-49:2007 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 August 2007 BSI 2007 ISBN 978 0 580 54313 5 National fo

3、reword This British Standard is the UK implementation of EN 61300-2-49:2007. It is identical to IEC 61300-2-49:2007. The UK participation in its preparation was entrusted by Technical Committee GEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre optic interconnecting devices and passive components

4、. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard cannot confer immunity f

5、rom legal obligations. Amendments issued since publication Amd. No. DateComments Licensed Copy: London South Bank University, London South Bank University, Sat Sep 01 03:19:42 GMT+00:00 2007, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD EN 61300-2-49 NORME EUROPENNE EUROPISCHE NORM August 2007 CENEL

6、EC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2007 CENELEC - All rights of exploitation in any form and by any means reserved world

7、wide for CENELEC members. Ref. No. EN 61300-2-49:2007 E ICS 33.180.20 English version Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-49: Tests - Connector installation test (IEC 61300-2-49:2007) Dispositifs dinterconnexion et composants pa

8、ssifs fibres optiques - Mthodes fondamentales dessais et de mesures - Partie 2-49: Essais - Essai dinstallation de connecteur (CEI 61300-2-49:2007) Lichtwellenleiter - Verbindungselemente und passive Bauteile - Grundlegende Prf- und Messverfahren - Teil 2-49: Prfungen - Einbauprfung fr Steckverbinde

9、r (IEC 61300-2-49:2007) This European Standard was approved by CENELEC on 2007-07-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date li

10、sts and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the

11、responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Ge

12、rmany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Licensed Copy: London South Bank University, London South Bank University, Sat Sep 01 03:1

13、9:42 GMT+00:00 2007, Uncontrolled Copy, (c) BSI Foreword The text of document 86B/2508/FDIS, future edition 1 of IEC 61300-2-49, prepared by SC 86B, Fibre optic interconnecting devices and passive components, of IEC TC 86, Fibre optics, was submitted to the IEC-CENELEC parallel vote and was approved

14、 by CENELEC as EN 61300-2-49 on 2007-07-01. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2008-04-01 latest date by which the national standards conflicting with the EN have

15、 to be withdrawn (dow) 2010-07-01 Annex ZA has been added by CENELEC. _ Notice This document contains material that is Copyright 2006, Telcordia Technologies, Inc. (“Telcordia“). All rights reserved. The reader is advised that this IEC document and Telcordia source(s) may differ, and the context and

16、 use of said material in this IEC document may differ from that of Telcordia. Telcordia makes no representation or warranty, express or implied, with respect to the sufficiency, accuracy, or utility of any information or opinion contained herein. Any use of or reliance upon said information or opini

17、on is at the risk of the user. Telcordia shall not be liable for any damage or injury incurred by any person arising out of the sufficiency, accuracy, or utility of any information or opinion contained herein. _ Endorsement notice The text of the International Standard IEC 61300-2-49:2007 was approv

18、ed by CENELEC as a European Standard without any modification. _ EN 61300-2-49:2007 2 Licensed Copy: London South Bank University, London South Bank University, Sat Sep 01 03:19:42 GMT+00:00 2007, Uncontrolled Copy, (c) BSI 3 EN 61300-2-49:2007 CONTENTS 1 Scope 4 2 Normative references .4 3 General

19、description 4 4 Apparatus.4 4.1 Mounting fixture.4 4.2 Panel 4 4.3 Optical source and detector .5 5 Procedure 5 5.1 Preparation of specimens 5 5.2 Pre-conditioning 5 5.3 Initial measurements6 5.4 Conditioning 6 5.5 Measuring the attenuation6 5.6 Applying the panel.6 5.7 Monitoring attenuation with t

20、he panel applied.6 5.8 Final measurements and examinations.6 6 Severity6 7 Details to be specified 7 Bibliography .8 Annex ZA (normative) Normative references to international publications with their corresponding European publications9 Figure 1 Example of the connector installation test .5 Table 1

21、Preferred wavelengths.5 Licensed Copy: London South Bank University, London South Bank University, Sat Sep 01 03:19:42 GMT+00:00 2007, Uncontrolled Copy, (c) BSI EN 61300-2-49:2007 4 FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS BASIC TEST AND MEASUREMENT PROCEDURES Part 2-49: Tests Con

22、nector installation test 1 Scope This part of IEC 61300 provides a test to determine that a connector is capable of functioning when installed in a cabinet or other enclosure in which the space available is limited. 2 Normative references The following referenced documents are indispensable for the

23、application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 61300-1, Fibre optic interconnecting devices and passive components Basic test and measurement procedures

24、Part 1: General guidance IEC 61300-3-1, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 3-1: Examinations and measurements Visual examination IEC 61300-3-4, Fibre optic interconnecting devices and passive components Basic test and measurement pro

25、cedures Part 3-4: Measurements Attenuation 3 General description The specimen is mounted into the test apparatus as shown in Figure 1. A panel is brought parallel to the mounting fixture and change in loss is measured. 4 Apparatus 4.1 Mounting fixture The mounting fixture is a vertical surface that

26、consists of a means to hold the device under test in a stable and representative manner. For connectors the mounting fixture will incorporate an adaptor. The mounting fixture shall be capable of accommodating those devices where the input and output fibre cables are co-located on the same side of th

27、e device. For connectors, where an adapter is used to connect two connectors, if there is more than one way to mount the adapter in the fixture, the adapter should be mounted so as to maximize the distance from the end of the connector to the panel. 4.2 Panel The panel consists of a flat surface tha

28、t is brought parallel to the mounting fixture to simulate a cabinet door closing on the installed device. Licensed Copy: London South Bank University, London South Bank University, Sat Sep 01 03:19:42 GMT+00:00 2007, Uncontrolled Copy, (c) BSI 5 EN 61300-2-49:2007 To detector To optical source Mount

29、ing fixture Device under test Panel Fibre cable For example, 70 mm IEC 952/07 Figure 1 Example of the connector installation test 4.3 Optical source and detector The optical source and detector used to measure changes in attenuation shall comply with that specified in IEC 61300-3-4. See Table 1 for

30、preferred wavelengths. Table 1 Preferred wavelengths Singlemode 1 310 nm and 1 550 nm, optional 1 625 nm Multimode 850 nm and 1300 nm 5 Procedure 5.1 Preparation of specimens Prepare the specimens according to the manufacturers instructions or as specified in the relevant specification. The device u

31、nder test shall be terminated with a sufficient length of fibre cable to facilitate interfacing with the optical source and detector. 5.2 Pre-conditioning Pre-condition the device under test for 2 h at the standard test conditions as given in IEC 61300-1, unless otherwise specified in the relevant s

32、pecification. Measure and record the attenuation of the device under test. Licensed Copy: London South Bank University, London South Bank University, Sat Sep 01 03:19:42 GMT+00:00 2007, Uncontrolled Copy, (c) BSI EN 61300-2-49:2007 6 5.3 Initial measurements Complete initial examinations and measure

33、ments on the specimen as required by the relevant specification. 5.4 Conditioning Clean the connector according to the manufacturers instructions. The body of the specimen shall be mounted in a representative manner onto the mounting fixture (see Figure 1). The jumper cable that exits from the devic

34、e under test is to be dressed so that about one metre of cable is supported by the end of the connector boot. 5.5 Measuring the attenuation Re-measure the attenuation to ensure that the fixturing has not affected the cables attenuation. 5.6 Applying the panel Bring the panel to a position that is pa

35、rallel to the mounting fixture surface and at a distance from the mounting panel as illustrated in Figure 1. 5.7 Monitoring attenuation with the panel applied The attenuation of the specimen shall be measured with the panel in position, as described in IEC 61300-3-4, unless otherwise specified in th

36、e relevant specification. Any deviation in the device attenuation from that measured in 5.5 shall be considered attributable to the cable/device interface, or to fibre-to-fibre interfaces in the device. 5.8 Final measurements and examinations On completion of the test, remove the panel and make a fi

37、nal attenuation measurement to ensure that there is no permanent damage to the device under test. Remove the device from the mounting fixture and, unless otherwise specified, visually examine the specimen in accordance with IEC 61300-3-1. Check for evidence of any degradation in the specimen. This m

38、ay include, for example: broken, loose or damaged parts or accessories; breaking or damage to the cable jacket, seals, strain relief, or fibres; displaced, bent, or broken parts; 6 Severity The severity of the test is dependent upon the distance of the panel from the samples mounting position and th

39、e length of the connector. Licensed Copy: London South Bank University, London South Bank University, Sat Sep 01 03:19:42 GMT+00:00 2007, Uncontrolled Copy, (c) BSI 7 EN 61300-2-49:2007 7 Details to be specified The following details, as applicable, shall be specified in the relevant specification:

40、distance of the panel to the mounting device/fixture; initial examinations, measurements and performance requirements; examinations, measurements and performance requirements during test; final examinations, measurements and performance requirements; deviations from this test method; additional pass

41、/fail criteria. Licensed Copy: London South Bank University, London South Bank University, Sat Sep 01 03:19:42 GMT+00:00 2007, Uncontrolled Copy, (c) BSI EN 61300-2-49:2007 8 Bibliography IEC 61300-3-3, Fibre optic interconnecting devices and passive components Basic test and measurement procedures

42、Part 3-3: Examinations and measurements Active monitoring of changes in attenuation and return loss _ NOTE Harmonized as EN 61300-3-3:2003 (not modified). Licensed Copy: London South Bank University, London South Bank University, Sat Sep 01 03:19:42 GMT+00:00 2007, Uncontrolled Copy, (c) BSI 9 EN 61

43、300-2-49:2007 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references

44、, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. PublicationYearTitleEN/HDYear IEC 61300-1 -1)Fibre optic interconnecting devices and p

45、assive components - Basic test and measurement procedures - Part 1: General and guidance EN 61300-1 20032) IEC 61300-3-1 -1)Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-1: Examinations and measurements - Visual examination EN 61300-3-1 2

46、0052) IEC 61300-3-4 -1)Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-4: Examinations and measurements - Attenuation EN 61300-3-4 20012) 1) Undated reference. 2) Valid edition at date of issue. Licensed Copy: London South Bank University,

47、London South Bank University, Sat Sep 01 03:19:42 GMT+00:00 2007, Uncontrolled Copy, (c) BSI BS EN 61300-2-49: 2007 BSI 389 Chiswick High Road London W4 4AL BSI British Standards Institution BSI is the independent national body responsible for preparing British Standards. It presents the UK view on

48、standards in Europe and at the international level. It is incorporated by Royal Charter. Revisions British Standards are updated by amendment or revision. Users of British Standards should make sure that they possess the latest amendments or editions. It is the constant aim of BSI to improve the quality of our products and services. We would be grateful if anyone finding an inaccuracy or ambiguity while using this British Standard would inform the Secretary of the technical committee responsible, the identity of which can be found on the inside front cover. Tel: +44 (0)20 8996 9000. F

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 其他


经营许可证编号:宁ICP备18001539号-1