1、 Reference number ISO 6182-3:2005(E) ISO 2005 INTERNATIONAL STANDARD ISO 6182-3 Second edition 2005-10-15 Fire protection Automatic sprinkler systems Part 3: Requirements and test methods for dry pipe valves Protection contre lincendie Systmes dextinction automatiques du type sprinkler Partie 3: Exi

2、gences et mthodes dessai des postes de contrle sous air Copyright International Organization for Standardization Provided by IHS under license with ISO Licensee=Hong Kong Polytechnic Univ/9976803100 Not for Resale, 04/17/2007 10:05:40 MDTNo reproduction or networking permitted without license from I

3、HS -,-,- ISO 6182-3:2005(E) PDF disclaimer This PDF file may contain embedded typefaces. In accordance with Adobes licensing policy, this file may be printed or viewed but shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing

4、. In downloading this file, parties accept therein the responsibility of not infringing Adobes licensing policy. The ISO Central Secretariat accepts no liability in this area. Adobe is a trademark of Adobe Systems Incorporated. Details of the software products used to create this PDF file can be fou

5、nd in the General Info relative to the file; the PDF-creation parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the

6、 address given below. ISO 2005 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or

7、 ISOs member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland ii ISO 2005 All rights reserved Copyright International Organization for Standardiza

8、tion Provided by IHS under license with ISO Licensee=Hong Kong Polytechnic Univ/9976803100 Not for Resale, 04/17/2007 10:05:40 MDTNo reproduction or networking permitted without license from IHS -,-,- ISO 6182-3:2005(E) ISO 2005 All rights reserved iii Contents Page Foreword iv Introduction v 1 Scop

9、e . 1 2 Normative references. 1 3 Terms and definitions. 1 4 Requirements 4 5 Production testing and quality control. 11 6 Tests. 11 7 Marking 18 8 Instruction charts and trim 19 Bibliography. 20 Copyright International Organization for Standardization Provided by IHS under license with ISO Licensee

10、=Hong Kong Polytechnic Univ/9976803100 Not for Resale, 04/17/2007 10:05:40 MDTNo reproduction or networking permitted without license from IHS -,-,- ISO 6182-3:2005(E) iv ISO 2005 All rights reserved Foreword ISO (the International Organization for Standardization) is a worldwide federation of natio

11、nal standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. Internati

12、onal organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rul

13、es given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at

14、least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 6182-3 was prepared by Technical Committee ISO/TC

15、 21, Equipment for fire protection and fire fighting, Subcommittee SC 5, Fixed firefighting systems using water. This second edition cancels and replaces the first edition (ISO 6182-3:1993), which has been technically revised. ISO 6182 consists of the following parts, under the general title Fire pr

16、otection Automatic sprinkler systems: Part 1: Requirements and test methods for sprinklers Part 2: Requirements and test methods for wet alarm valves, retard chambers and water motor alarms Part 3: Requirements and test methods for dry pipe valves Part 4: Requirements and test methods for quick-open

17、ing devices Part 5: Requirements and test methods for deluge valves Part 6: Requirements and test methods for check valves Part 7: Requirements and test methods for early suppression fast response (ESFR) sprinklers Part 8: Requirements and test methods for pre-action dry alarm valves Part 9: Require

18、ments and test methods for water mist nozzles Part 10: Requirements and test methods for domestic sprinklers Part 11: Requirements and test methods for pipe hangers Part 12: Requirements and test methods for couplings for grooved end pipe couplings Part 13: Requirements and test methods for extended

19、 coverage sprinklers Copyright International Organization for Standardization Provided by IHS under license with ISO Licensee=Hong Kong Polytechnic Univ/9976803100 Not for Resale, 04/17/2007 10:05:40 MDTNo reproduction or networking permitted without license from IHS -,-,- ISO 6182-3:2005(E) ISO 200

20、5 All rights reserved v Introduction This part of ISO 6182 is one of a number of ISO International Standards prepared by ISO/TC 21 covering components for automatic sprinkler systems, including the following: a) carbon dioxide systems (ISO 6183); b) explosion suppression systems (ISO 6184). An Inter

21、national Standard covering foam systems is planned. Copyright International Organization for Standardization Provided by IHS under license with ISO Licensee=Hong Kong Polytechnic Univ/9976803100 Not for Resale, 04/17/2007 10:05:40 MDTNo reproduction or networking permitted without license from IHS -

22、,-,- Copyright International Organization for Standardization Provided by IHS under license with ISO Licensee=Hong Kong Polytechnic Univ/9976803100 Not for Resale, 04/17/2007 10:05:40 MDTNo reproduction or networking permitted without license from IHS -,-,- INTERNATIONAL STANDARD ISO 6182-3:2005(E)

23、ISO 2005 All rights reserved 1 Fire protection Automatic sprinkler systems Part 3: Requirements and test methods for dry pipe valves 1 Scope This part of ISO 6182 specifies performance, requirements, methods of test and marking requirements, for dry pipe valves and manufacturers specified relevant t

24、rim used in dry pipe automatic fire protection systems. Performance and test requirements for other auxiliary components or attachments to dry pipe valves are not covered by this part of ISO 6182. 2 Normative references The following referenced documents are indispensable for the application of this

25、 document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 7-1, Pipe threads where pressure-tight joints are made on the threads Part 1: Dimensions, tolerances, and designation ISO 37,

26、 Rubber, vulcanized or thermoplastic Determination of tensile stress-strain properties ISO 188, Rubber, vulcanized or thermoplastic Accelerated ageing and heat resistance tests ISO 898-1, Mechanical properties of fasteners made of carbon steel and alloy steel Part 1: Bolts, screws and studs ISO 898-

27、2, Mechanical properties of fasteners Part 2: Nuts with specified proof load values Coarse thread 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 alarm device mechanical or electrical device to sound an alarm upon operation of the valve 3.2 a

28、utomatic drain valve normally open device that automatically drains water from and vents the intermediate chamber of a valve to the atmosphere when the valve is in the ready position, and limits water flow from the chamber after the valve has tripped Copyright International Organization for Standard

29、ization Provided by IHS under license with ISO Licensee=Hong Kong Polytechnic Univ/9976803100 Not for Resale, 04/17/2007 10:05:40 MDTNo reproduction or networking permitted without license from IHS -,-,- ISO 6182-3:2005(E) 2 ISO 2005 All rights reserved 3.3 clapper type of sealing element NOTE See a

30、lso 3.17. 3.4 corrosion-resistant material metallic material of bronze, brass, Monel 1) metal, austenitic stainless steel, or equivalent, or plastic material conforming with the requirements of this document 3.5 differential ratio of service pressure to system air pressure (expressed as gauge pressu

31、res) at the trip point NOTE See also 3.23. 3.6 differential-type valve type of valve in which air pressure in the system acts directly and/or indirectly on the sealing assembly to maintain it in the closed position NOTE The air seat of the sealing assembly is of equal or larger diameter than the dia

32、meter of the water seat of the sealing assembly, with the two separated by an intermediate chamber maintained at atmospheric pressure. 3.7 dry pipe system automatic fire protection system in which the piping contains air or nitrogen under pressure, the release of which allows water from a water supp

33、ly to discharge through the system 3.8 dry pipe valve valve that controls the flow of water into a dry pipe sprinkler system and incorporates provision for actuation of an alarm under specified conditions 3.9 flow velocity speed of water flow through a valve expressed as the equivalent water velocit

34、y through a pipe of the same nominal size as the valve 3.10 intermediate chamber that part of a valve which separates the air and/or water sealing assembly seating surfaces and is at atmospheric pressure when the valve is in the ready condition 3.11 leak point system air pressure for a specific serv

35、ice pressure at which water begins to flow from the intermediate chamber, automatic drain valve or alarm connection 3.12 mechanical-type valve type of valve in which the air pressure in the system acts on the sealing assembly and linking mechanism to maintain it in the closed position 1) Monel is an

36、 example of a suitable product available commercially. This information is given for the convenience of users of this part of ISO 6182 and does not constitute an endorsement by ISO of this product. Copyright International Organization for Standardization Provided by IHS under license with ISO Licens

37、ee=Hong Kong Polytechnic Univ/9976803100 Not for Resale, 04/17/2007 10:05:40 MDTNo reproduction or networking permitted without license from IHS -,-,- ISO 6182-3:2005(E) ISO 2005 All rights reserved 3 3.13 priming water water used to seal a sealing assembly and prevent cementation of working parts 3

38、.14 rated working pressure maximum service pressure at which a valve or retard chamber is intended to operate 3.15 ready (set) condition state of a valve with the sealing assembly in the closed or set position with service and system pressure applied 3.16 reinforced elastomeric element element of cl

39、apper, clapper assembly or seat seals in a composite of an elastomeric compound with one or more other components 3.17 sealing assembly main movable sealing element (such as a clapper) of the valve which prevents the reverse flow of water and which maintains air pressure in the system piping 3.18 se

40、aling assembly seat ring main fixed sealing element of a valve which prevents the reverse flow of water and which maintains air pressure in the system piping 3.19 service pressure static water pressure at the inlet to a valve when the valve is in the ready condition 3.20 system pressure static water

41、 pressure at the main outlet of a valve when the valve is in the ready condition 3.21 system air pressure static air pressure in the system piping when the valve is in the ready condition 3.22 trim external equipment and pipework, excluding the main installation pipework, fitted to valve installatio

42、n assembly 3.23 trip point point at which a valve operates, admitting water into the system, measured in terms of the system air pressure at a given service pressure 3.24 water motor alarm hydraulically actuated device which provides a local audible alarm as a result of a flow through a valve 3.25 w

43、ater motor transmitter hydraulically actuated device which generates an electrical current for a remote alarm as a result of operation of the valve Copyright International Organization for Standardization Provided by IHS under license with ISO Licensee=Hong Kong Polytechnic Univ/9976803100 Not for R

44、esale, 04/17/2007 10:05:40 MDTNo reproduction or networking permitted without license from IHS -,-,- ISO 6182-3:2005(E) 4 ISO 2005 All rights reserved 4 Requirements 4.1 Nominal sizes The nominal size of a valve shall be the nominal diameter of the inlet and outlet connections, i.e. the pipe size fo

45、r which the connections are intended. Sizes shall be 40 mm, 50 mm, 65 mm, 80 mm, 100 mm, 125 mm, 150 mm, 200 mm, 250 mm or 300 mm. The diameter of the waterway through the sealing assembly seat ring may be less than the nominal size. 4.2 Connections 4.2.1 All connections shall have been designed for

46、 use at the rated working pressure of the valve. 4.2.2 The dimensions of all connections shall conform with the applicable requirements of International Standards. If International Standards are not applicable, National standards shall be permitted to be used. 4.2.3 An opening not smaller than 15 mm

47、 nominal diameter shall be provided for an alarm line connection. 4.2.4 If priming water is required to seal the downstream side of the sealing assembly, an external means shall be provided to introduce the priming water. 4.2.5 Means shall be provided to prevent water columning and to check the leve

48、l of priming water. 4.2.6 Suitable means shall be provided to facilitate testing of alarms without tripping the valve. 4.2.7 Valves shall be provided with a means of sounding an alarm if water enters the downstream piping to an elevation exceeding 0,5 m above the sealing assembly, unless the valve is provided with an automatic means for drainage. 4.2.8 For differential-type valves, suitable means sh