AS NZS 2442.1-1996 Amdt 2-1999 Performance of household electrical appliances-Rotary clothes dryers.pdf

上传人:韩长文 文档编号:3641924 上传时间:2019-09-19 格式:PDF 页数:4 大小:51.26KB
返回 下载 相关 举报
AS NZS 2442.1-1996 Amdt 2-1999 Performance of household electrical appliances-Rotary clothes dryers.pdf_第1页
第1页 / 共4页
AS NZS 2442.1-1996 Amdt 2-1999 Performance of household electrical appliances-Rotary clothes dryers.pdf_第2页
第2页 / 共4页
AS NZS 2442.1-1996 Amdt 2-1999 Performance of household electrical appliances-Rotary clothes dryers.pdf_第3页
第3页 / 共4页
AS NZS 2442.1-1996 Amdt 2-1999 Performance of household electrical appliances-Rotary clothes dryers.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

《AS NZS 2442.1-1996 Amdt 2-1999 Performance of household electrical appliances-Rotary clothes dryers.pdf》由会员分享,可在线阅读,更多相关《AS NZS 2442.1-1996 Amdt 2-1999 Performance of household electrical appliances-Rotary clothes dryers.pdf(4页珍藏版)》请在三一文库上搜索。

1、AS/NZS 2442.1/Amdt 2/1999-09-05 STANDARDS AUSTRALIA/STANDARDS NEW ZEALAND Amendment No. 2 to AS/NZS 2442.1:1996 Performance of household electrical appliancesRotary clothes dryers Part 1: Energy consumption and performance REVISED TEXT The 1996 edition of AS/NZS 2442.1 is amended as follows; the ame

2、ndments should be inserted in the appropriate places. SUMMARY: This Amendment applies to Clauses 3.5 and 3.7 and Appendices D, F and G. Published on 5 September 1999. AMDT No. 2 SEP. 1999 Page 8Clause 3.5 Delete the existing text and replace with the following: Except where stated otherwise in Parag

3、raph D2.4, Appendix D, the following shall apply: (a)Manual and timer dryers shall be set on maximum temperature. (b)Autosensing dryers shall be set on the chosen program, i.e. the program under test. (c)Where the drying temperature can be chosen independently of the program on an autosensing dryer,

4、 it shall be set to the maximum. An autosensing dryer with supplementary timer shall be tested as an autosensing dryer. AMDT No. 2 SEP. 1999 Page 8Clause 3.7 Delete the existing text and replace with the following: Except where stated otherwise in Paragraph D3.1(b), Appendix D, a standard damp load

5、in accordance with Paragraph E3 of Appendix E shall be loaded into the dryer, before each run, in accordance with the manufacturers instructions. Where no manufacturers instructions are available, the garments shall be shaken individually and loaded loosely. AMDT No. 2 SEP. 1999 Page 21Appendix D Pa

6、ragraph D3.1(b) Delete the existing Step (b) and replace with the following: (b)Load the dryer as specified in Clause 3.7, except that the load shall be bone-dry in accordance with Paragraph E2.5, Appendix E. Start the dryer. ISBN 0 7337 2879 0 Accessed by UNIVERSITY OF SOUTH AUSTRALIA on 14 Aug 200

7、7 AMDT No. 2 SEP. 1999 Page 21Appendix D Paragraph D3.1(c) Delete the existing Step (c) and replace with the following: (c)Operate the dryer until (i)the temperature of the exhaust air is stabilized; or (ii)the temperature of the exhaust air cycles in a consistent manner between the same temperature

8、 limits; or (iii)in the case of a dryer where there is no-exhaust air (e.g. some types of condenser dryers), the beginning of the cool-down period at the end of one full run (if applicable) or the end of one full run; or (iv)in the case of an autosensing dryer, the beginning of the cool-down period

9、prior to automatic switch-off (if applicable) or automatic switch-off. AMDT No. 2 SEP. 1999 Page 21Appendix D Paragraph D3.1(d) Delete the first two sentences from Step (d) and replace with the following: (d)If Step (c)(i) applies, stop the dryer. If Step (c)(ii) applies, stop the dryer when the tem

10、perature is at the maximum point of the cycle. If Step (c)(iii) or (c)(iv) applies, stop the dryer immediately the cool-down period begins. AMDT No. 2 SEP. 1999 Page 22Appendix D Paragraph D3.2(c) Delete the existing Step (c) and replace with the following: (c)Operate the dryer for the period specif

11、ied in Paragraph D3.1(c). AMDT No. 2 SEP. 1999 Page 26Appendix F Paragraph F3.2(a) Delete 23 2C and the Note and replace with 20 2C. AMDT No. 2 SEP. 1999 Page 32Appendix G Test report format G2 (contd) From the second line, delete Calculated energyE6%atm6%(=Et) (kWh) and replace with the following:

12、Calculated energyEt, =E6%atm6%(kWh) AMDT No. 2 SEP. 1999 Page 33Appendix G Test report format G3 From the fourth line, delete EnergyE6%atm6% and replace with the following: EnergyEt, =E6%atm6%(kWh) AMDT No. 2 SEP. 1999 Page 33Appendix G Test report format G3 In the fifth line, insert (litres) after

13、m6%. Accessed by UNIVERSITY OF SOUTH AUSTRALIA on 14 Aug 2007 AMDT No. 2 SEP. 1999 Page 34Appendix G Test report format G4 From the tenth line delete Tested energy performance (TEP) =E6%/mr and replace with the following: Tested energy performance (TEP) =Et/mr AMDT No. 2 SEP. 1999 Page 35Appendix G

14、Test report format G5 From the sixth last line, delete Calculated energyE6%atm6%(=Et) (kWh) and replace with the following: Calculated energyEt, =E6%atm6%(kWh) AMDT No. 2 SEP. 1999 Page 35Appendix G Test report format G5 From the third last line delete Tested energy performance (TEP) =Et/mr(kWh/kg) and replace with the following: Tested energy performance (TEP) =E6%/mr(kWh/kg) Accessed by UNIVERSITY OF SOUTH AUSTRALIA on 14 Aug 2007 This page has been left blank intentionally. Accessed by UNIVERSITY OF SOUTH AUSTRALIA on 14 Aug 2007