BS-EN-50250-1999.pdf

上传人:小小飞 文档编号:3744866 上传时间:2019-09-22 格式:PDF 页数:18 大小:167.09KB
返回 下载 相关 举报
BS-EN-50250-1999.pdf_第1页
第1页 / 共18页
BS-EN-50250-1999.pdf_第2页
第2页 / 共18页
BS-EN-50250-1999.pdf_第3页
第3页 / 共18页
BS-EN-50250-1999.pdf_第4页
第4页 / 共18页
BS-EN-50250-1999.pdf_第5页
第5页 / 共18页
亲,该文档总共18页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《BS-EN-50250-1999.pdf》由会员分享,可在线阅读,更多相关《BS-EN-50250-1999.pdf(18页珍藏版)》请在三一文库上搜索。

1、| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | BRITISH STANDARD BS EN 50250:1999 The Euro

2、pean Standard EN 50250:1998 has the status of a British Standard ICS 29.120.30 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW Conversion adaptors for industrial use Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 06 07:19:46 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS E

3、N 50250:1999 This British Standard, having been prepared under the direction of the Electrotechnical Sector Committee, was published under the authority of the Standards Committee and comes into effect on 15 March 1999 BSI 03-1999 ISBN 0 580 32131 2 Amendments issued since publication Amd. No.DateTe

4、xt affected National foreword This British Standard is the English language version of EN 50250:1998. The UK participation in its preparation was entrusted by Technical Committee PEL/23, Installed electrical accessories, to Subcommittee PEL/23/4, Protected type plugs and sockets, which has the respo

5、nsibility to: aid enquirers to understand the text; present to the responsible European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. A list of organiz

6、ations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled International Standar

7、ds Correspondence Index, or by using the Find facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard do

8、es not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 15 and a back cover. Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 06 07:19:46 GMT+00:00 2006, Uncontrolled Copy, (c) BSI CENELE

9、C European Committee for Electrotechnical Standardization Comite Europe en de Normalisation Electrotechnique Europa isches Komitee fu r Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B-1050 Brussels 1998 CENELEC All rights of exploitation in any form and by any means reserved wor

10、ldwide for CENELEC members. Ref. No. 50250:1998 E EUROPEAN STANDARDEN 50250 NORME EUROPE ENNE EUROPA ISCHE NORM July 1998 ICS 29.120.20 Descriptors: electrical equipment, industrial facilities, low voltage, connecting equipment, conversion adapters, definitions, specifications, characteristics, test

11、s English version Conversion adapters for industrial use Adaptateurs de conversion pour usages industrielsU bergangsadapter fu r industrielle Anwendung This European Standard was approved by CENELEC on 1998-04-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which st

12、ipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Stan

13、dard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the natio

14、nal electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland,Italy,Luxembourg,Netherlands,Norway,Portugal,Spain,Sweden, Switzerland and United Kingdom. Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 06 07:19:46 GMT+00:00 2006,

15、Uncontrolled Copy, (c) BSI Page 2 EN 50250:1998 BSI 03-1999 Foreword This European Standard was prepared by the CENELEC BTWG 79-1, Conversion adapters for industrial use. The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50250 on 1998-04-01. The following dates

16、 were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement(dop) 1999-02-01 latest date by which the national standards conflicting with the EN have to be withdrawn(dow) 1999-02-01 This European Standard is to be

17、 used in conjunction with EN 60309-1. The clauses in this European Standard amend or replace the clauses of EN 60309-1. Subclauses, tables and figures which are additional to these in EN 60309-1 are numbered starting with 101. Additional annexes are lettered AA, BB, etc. Contents Page Foreword2 Intr

18、oduction3 1Scope3 2Definitions3 3Normative references3 4General3 5Standard ratings4 6Classification4 7Marking4 8Dimensions5 9Protection against electric shock6 10Provision for earthing6 11Terminals7 12Retaining devices8 13Resistance to ageing of rubber and thermoplastics material8 14General construc

19、tion8 15Construction of socket-outlets8 16Construction of adaptors8 17Construction of appliance inlets9 18Degrees of protection9 19Insulation resistance and dielectric strength9 20Breaking capacity10 21Normal operation10 22Temperature rise10 23Flexible cables and their connection11 24Mechanical stre

20、ngth11 25Screws, current-carrying parts and connections11 26Creepage distances, clearances and distances through sealing compound11 27Resistance to heat, fire and tracking12 28Resistance to rusting12 Annex AA (normative) National standards for socket-outlets for household and similar use15 Annex BB

21、(informative) A-deviations15 Annex CC (normative) Special national conditions15 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 06 07:19:46 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 3 EN 50250:1998 BSI 03-1999 Introduction This standard applies to conversion adapters, hereinafter referred

22、to as adapters, for industrial use comprising a housing incorporating a plug and socket-outlets which can be used to connect one or two plugs of the domestic type to an industrial 2P +16 A, 250 V 6 h, type socket-outlet. This standard shall be used jointly with standards EN 60309-1, Plugs, socket-ou

23、tlets and couplers for industrial purposes Part 1: General requirements, EN 60309-2, Plugs, socket-outlets and couplers for industrial purposes Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories of harmonized configurations, and with the relevant national standa

24、rds for socket-outlets for household and similar use (listed in annex AA). The clauses in this standard amend or replace the clauses of the above mentioned standard EN 60309-1. 1 Scope Replacement: This standard applies to conversion adapters intended mainly for industrial use, comprising a housing

25、of insulating material which incorporates an industrial 2 P +, 16 A, 6 h 250 V type plug part (Table 104 in EN 60309-2) and one or two socket-outlets in accordance with the relevant national standards for socket-outlets for household and similar use, with a rated current up to 16 A, intended mainly

26、for industrial use either indoors or outdoors. NOTEAdapters with three socket-outlets or a different type of plug part, according to EN 60309-2, are under consideration. This standard applies to all applications where the ambient temperature does not normally exceed 40 8C. The use of these adapters

27、on building sites, for agricultural, commercial and domestic applications is not precluded but care should be taken in considering protecting devices in use. Adapters are for temporary use only. In locations where special conditions prevail, for example on board ship or where explosions are liable t

28、o occur, additional requirements may be necessary. 2 Definitions This clause of EN 60309-1 is applicable with the following additions. 2.101 adapter portable accessory which allows the connection of one or more types of plug to a socket-outlet not designed to accept such plugs 2.101.1 single adapter

29、 adapter having a single plug function and a single socket-outlet function 2.101.2 double adapter adapter having a single plug function and two socket-outlet functions. The two socket-outlets may or may not comply with the same dimensional requirements 2.102 rated current of an adapter the rated cur

30、rent of an adapter is: the rated current of the plug part of the adapter; the sum of the rated currents of the plugs that can be inserted into the adapter, whichever is the lower 2.103 serviceable adapter an adapter which can be disassembled, using ordinary tools (e.g. screwdrivers, etc.) for replac

31、ement or maintenance 2.104 non-serviceable adapter an adapter which cannot be disassembled using ordinary tools (e.g. screwdrivers, etc.) without rendering it permanently useless 3 Normative references This clause of EN 60309-1 is applicable with the following additions. EN 60309-1:1997, Plugs, sock

32、et-outlets and couplers for industrial purposes Part 1: General requirements. (IEC 60309-1:1997) EN 60309-2:1998, Plugs, socket-outlets and couplers for industrial purposes Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories. (IEC 60309-2:1997 + corrigendum 1998)

33、 NOTESee annex AA for national standards for domestic socket-outlets. 4 General This clause of EN 60309-1 is applicable except as follows. 4.1 General requirements Replacement: Adapters shall be so designed and constructed that in normal use their performance is reliable and without danger to the us

34、er or surroundings. In general compliance is checked by carrying out all the tests specified. Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 06 07:19:46 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 4 EN 50250:1998 BSI 03-1999 4.2 General notes on tests 4.2.1 Replacement: Tests according to t

35、his standard are type tests. The parts of adapters are tested, unless otherwise specified, in accordance with the requirements of the relevant standard, as applicable; e.g. plug part is tested according to EN 60309-2 and socket-outlet parts are tested according to the relevant national standards. 4.

36、2.4 Replacement: Unless otherwise specified, one set of three specimens shall be subjected to all the tests. 4.2.5 Replace the first paragraph of the note by: NOTEIn general, it will only be necessary to repeat the tests which caused the failure, unless the specimens fail in test of clause 21, in wh

37、ich case tests shall be repeated from clause 20 onwards. Addition: 4.2.101 If gauges are used, these shall be of hardened steel, and all corners shall be slightly rounded-off with a maximum radius of 0,1 mm and the surface-finish for all measurement-surfaces shall be otherwise specified. min., unles

38、s 5 Standard ratings Replacement: 5.1 Rated voltage: The recommended rated voltage is 250 V. 5.2 Rated current: Rated current: 10 A, 13 A , 15 A and 16 A. 6 Classification Replacement: 6.1 Adapters are classified: 6.1.1 According to the degree of protection against harmful ingress of water in accord

39、ance with EN 60529: IPX0 (non-protected); IP $ X4 (protected). NOTEThe degree of protection of the socket-outlets for industrial use, when used in conjunction with an adapter, will revert to the protection rating of the adapter if this is less than that of the socket-outlet. 6.1.2 According to the t

40、ype of construction: serviceable adapters; non-serviceable adapters. 7 Marking Replacement: 7.1 Adapters shall be marked with: rated current in amperes; rated operating voltage or range in volts; symbol for nature of supply; either the name or trade mark of the manufacturer or of the responsible ven

41、dor; type reference, which may be a catalogue number; symbol for degree of protection (IP code); symbol indicating the position of the earthing contact (plug part side); wording for temporary use only. For adapters with degree of protection IPX0 is required a leaflet indicating to be aware in use of

42、 it because it reduces the degree of protection of the industrial socket-outlet in which will be inserted and that it shall not be used in environment with an explosion hazards. NOTE 1 This wording shall be written in the official language of the country of intended use. Compliance is checked by ins

43、pection. NOTE 2 Marking 10/16 shall be accepted as indication for socket-outlet parts in accordance with standard CEE 7. The symbol indicating the position of the earthing contact shall be placed before or above the figure indicating the rated operating voltage, and separated from it by a line. Thes

44、e markings shall be placed after that for rated current, separated from it by a dash, if an oblique line separates the symbol indicating the position of the earthing contact from the figure for the rated operating voltage. If a symbol for nature of supply is used, it shall be placed next to or below

45、 the marking for rated operating voltage. The marking for rated current, position of the earthing contact, rated operating voltage(s) and the nature of the supply may accordingly be as follows: 16 A 2 6 h/250 V, or 16 2 6 h/250, or 16 2 6h 250 7.2 When symbols are used, they shall be as follows: Aam

46、peres Vvolts alternating current earth IPXX degree of protection according to EN 60529 For marking of rated current(s) and rated operating voltage(s) or range(s), figures may be used alone. Compliance is checked by inspection. 7.3 The marking specified in 7.1 shall be readily visible when the adapte

47、r is equipped and ready for use, with the exception of the wording for temporary use only, which shall also be visible when the adapter is in use. NOTE 1 The term ready for use does not imply that the adapter is in engagement with its complementary accessory. NOTE 2 The marking for rated current, na

48、ture of supply, rated operating voltage and the name, trade mark of the manufacturer or the responsible vendor, may be repeated on the lid, if any. Compliance is checked by inspection. Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 06 07:19:46 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 5 E

49、N 50250:1998 BSI 03-1999 7.4 In serviceable adapters the earthing contacts shall be indicated by the symbol. This symbol shall be placed close to the corresponding terminals, and should not be placed on screws, washers or other removable parts. 7.5 Markings shall be indelible and easily legible. Compliance is checked by inspection and by the following test. After the humidity treatment in clause 18 the marking shall be rubbed vigorously by hand for 15 s with a piece of cloth soaked in water and again for 15 s