BS-EN-62056-42-2002 IEC-62056-42-2002.pdf

上传人:小小飞 文档编号:3745676 上传时间:2019-09-22 格式:PDF 页数:30 大小:444.89KB
返回 下载 相关 举报
BS-EN-62056-42-2002 IEC-62056-42-2002.pdf_第1页
第1页 / 共30页
BS-EN-62056-42-2002 IEC-62056-42-2002.pdf_第2页
第2页 / 共30页
BS-EN-62056-42-2002 IEC-62056-42-2002.pdf_第3页
第3页 / 共30页
BS-EN-62056-42-2002 IEC-62056-42-2002.pdf_第4页
第4页 / 共30页
BS-EN-62056-42-2002 IEC-62056-42-2002.pdf_第5页
第5页 / 共30页
亲,该文档总共30页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《BS-EN-62056-42-2002 IEC-62056-42-2002.pdf》由会员分享,可在线阅读,更多相关《BS-EN-62056-42-2002 IEC-62056-42-2002.pdf(30页珍藏版)》请在三一文库上搜索。

1、BRITISH STANDARD BS EN 62056-42:2002 IEC 62056-42:2002 Electricity metering Data exchange for meter reading, tariff and load control Part 42: Physical layer services and procedures for connection-oriented asynchronous data exchange The European Standard EN 62056-42:2002 has the status of a British S

2、tandard ICS 91.140.50; 35.100.10 ? Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 12:44:48 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 62056-42:2002 This British Standard, having been prepared under the direction of the Electrotechnical Sector Policy and Strategy Committee, was publishe

3、d under the authority of the Standards Policy and Strategy Committee on 16 July 2002 BSI 16 July 2002 ISBN 0 580 39993 1 National foreword This British Standard is the official English language version of EN 62056-42:2002. It is identical with IEC 62056-42:2002. The UK participation in its preparati

4、on was entrusted to Technical Committee PEL/13, Electricity meters, which has the responsibility to: A list of organizations represented on this committee can be obtained on request to its secretary. From 1 January 1997, all IEC publications have the number 60000 added to the old number. For instanc

5、e, IEC 27-1 has been renumbered as IEC 60027-1. For a period of time during the change over from one numbering system to the other, publications may contain identifiers from both systems. Cross-references The British Standards which implement international or European publications referred to in thi

6、s document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. User

7、s of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, o

8、r proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 27, and a back cover. The BSI copyright date

9、 displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. DateComments Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 12:44:48 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARDEN 62056-42 NORME EUROPENNE EUROPISCHE NORMJu

10、ne 2002 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2002 CENELEC -All rights of exploitation in any form and by any means re

11、served worldwide for CENELEC members. Ref. No. EN 62056-42:2002 E ICS 91.140.50; 35.100.10 English version Electricity metering - Data exchange for meter reading, tariff and load control Part 42: Physical layer services and procedures for connection-oriented asynchronous data exchange (IEC 62056-42:

12、2002) Equipements de mesure de lnergie lectrique - Echange des donnes pour la lecture des compteurs, le contrle des tarifs et de la charge Partie 42: Services et procdures de la couche physique pour lchange de donnes laide de connexion asynchrone (CEI 62056-42:2002) Messung der elektrischen Energie

13、- Zhlerstandsbertragung, Tarif- und Laststeuerung Teil 42: Bitbertragungsschichtdienste und Verfahren fr verbindungsorientierten asynchronen Datenaustausch (IEC 62056-42:2002) This European Standard was approved by CENELEC on 2002-03-01. CENELEC members are bound to comply with the CEN/CENELEC Inter

14、nal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC me

15、mber. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENEL

16、EC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom. Licensed Copy: sheffiel

17、dun sheffieldun, na, Mon Nov 13 12:44:48 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Foreword The text of document 13/1266/FDIS, future edition 1 of IEC 62056-42, prepared by IEC TC 13, Equipment for electrical energy measurement and load control, was submitted to the IEC-CENELEC parallel vote and wa

18、s approved by CENELEC as EN 62056-42 on 2002-03-01. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement(dop) 2003-01-01 latest date by which the national standards conflicting with the

19、EN have to be withdrawn(dow) 2005-03-01 The International Electrotechnical Commission (IEC) and CENELEC draw attention to the fact that it is claimed that compliance with this International Standard / European Standard may involve the use of a maintenance service concerning the stack of protocols on

20、 which the present standard IEC 62056-42 / EN 62056-42 is based. The IEC and CENELEC take no position concerning the evidence, validity and scope of this maintenance service. The provider of the maintenance service has assured the IEC that he is willing to provide services under reasonable and non-d

21、iscriminatory terms and conditions with applicants throughout the world. In this respect, the statement of the provider of the maintenance service is registered with the IEC. Information (see also 6.3.3) may be obtained from: DLMS1) User Association Geneva / Switzerland www.dlms.ch Annexes designate

22、d “normative“ are part of the body of the standard. Annexes designated “informative“ are given for information only. In this standard, annexe ZA is normative and annexes A and B are informative. Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 62056

23、-42:2002 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 61334-4-41NOTEHarmonized as EN 61334-4-41:1996 (not modified). IEC 61334-6NOTEHarmonized as EN 61334-6:20

24、00 (not modified). _ 1) Device Language Message Specification 2 egaP 2002:2465026 NE 2002 enuJ 61 Page 4 BSI 16 July 2002 Page 2 EN 6205642:2002 BSI 16 July 2002 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 12:44:48 GMT+00:00 2006, Uncontrolled Copy, (c) BSI 260-6542 ? CEI:0220(E) 3 CONTEN

25、TS 1Scope.4 2Normative references .4 3Terms, definitions and abbreviations 5 4Overview 6 5Service specification.7 5.1List of services 7 5.1.1Connection establishment/release related services7 5.1.2Data communication services 7 5.1.3Layer management services 7 5.2Use of the physical layer services .8

26、 5.3Service definitions.8 5.3.1PH-CONNECT.request 8 5.3.2PH-CONNECT.indication .9 5.3.3PH-CONNECT.confirm 9 5.3.4PH-ABORT.request .10 5.3.5PH-ABORT.confirm .10 5.3.6PH-ABORT.indication 10 5.3.7PH-DATA.request11 5.3.8PH-DATA.indication.11 6Protocol specification .12 6.1Physical layer protocol data un

27、it12 6.2Transmission order and characteristics .12 6.3Physical layer operation description of the procedures .12 6.3.1General .12 6.3.2Setting up a physical connection .13 6.3.3 The identification service.14 6.3.4 Data communications 18 6.3.5 Disconnection of an existing physical connection.18 Annex

28、 A (informative) An example: PH service primitives and Hayes commands 19 Annex B (informative) Data model and protocol 24 Annex ZA (normative) Normative references to international publications with their corresponding European publications .27 Bibliography25 Figure 1 Typical PSTN configuration6 Fig

29、ure 2 The location of the physical layer .7 Figure 3 Protocol layer services of the COSEM 3-layer connection oriented profile8 Figure 4 MSC for physical connection establishment14 Figure 5 MSC for IDENTIFY.request/.response message exchange .16 Figure 6 Handling the identification service at the COS

30、EM server side.16 Figure 7 Partial state machine for the client side physical layer17 Figure A.1 MSC for physical connection request 19 Figure A.2 Physical connection establishment at the CALLING station.20 Figure A.3 MSC for physical connection establishment 21 Figure A.4 Data exchange between the

31、calling and called stations.22 Figure A.5 MSC for a physical disconnection .23 Figure B.1 The three-step approach of COSEM .24 3 egaP 2002:2465026 NE 2002 enuJ 61 Page 5 BSI 16 July 2002 Page 3 EN 6205642:2002 BSI 16 July 2002 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 12:44:48 GMT+00:00

32、 2006, Uncontrolled Copy, (c) BSI 4 620-6542 ? CEI:0220(E) ELECTRICITY METERING DATA EXCHANGE FOR METER READING, TARIFF AND LOAD CONTROL Part 42: Physical layer services and procedures for connection-oriented asynchronous data exchange 1 Scope This part of IEC 62056 specifies the physical layer serv

33、ices and protocols within the Companion Specification for Energy Metering (COSEM) three-layer connection oriented profile for asynchronous data communication. The document does not specify physical layer signals and mechanical aspects. Local, implementation-specific issues are also not specified. In

34、 annex A, an example of how this physical layer can be used for data exchange through the Public Switched Telephone Network (PSTN) using intelligent Hayes modems is given. The use of the physical layer for the purposes of direct local data exchange using an optical port or a current loop physical in

35、terface is specified in IEC 62056-21. Annex B gives an explanation of the role of data models and protocols in electricity meter data exchange. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cit

36、ed applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60050-300:2001, International Electrotechnical Vocabulary Electrical and electronic measurements and measuring instruments Part 311: General terms relating to measurements Part 3

37、12: General terms relating to electrical measurements Part 313: Types of electrical measuring instruments Part 314: Specific terms according to the type of instrument IEC/TR 62051:1999, Electricity metering Glossary of terms IEC 62056-21, Electricity metering Data exchange for meter reading, tariff

38、and load control Part 21: Direct local data exchange 1 IEC 62056-46, Electricity metering Data exchange for meter reading, tariff and load control Part 46: Data link layer using HDLC protocol 1 IEC 62056-53, Electricity metering Data exchange for meter reading, tariff and load control Part 53: COSEM

39、 application layer 1 IEC 62056-61, Electricity metering Data exchange for meter reading, tariff and load control Part 61: OBIS Object identification system 1 IEC 62056-62, Electricity metering Data exchange for meter reading, tariff and load control Part 62: Interface objects 1 NEMA C12.21:1999, Pro

40、tocol Specification for Telephone Modem Communication _ 1 To be published. 4 egaP 2002:2465026 NE 2002 enuJ 61 Page 6 BSI 16 July 2002 Page 4 EN 6205642:2002 BSI 16 July 2002 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 12:44:48 GMT+00:00 2006, Uncontrolled Copy, (c) BSI 260-6542 ? CEI:022

41、0(E) 5 3 Terms, definitions and abbreviations 3.1 Terms and definitions For the purpose of this part of IEC 62056, the definitions in IEC 60050-300 and IEC/TR 62051 as well as the following definitions apply: 3.1.1 client a station asking for services, normally the master station 3.1.2 master centra

42、l station station which takes the initiative and controls the data flow 3.1.3 server a station delivering services. The tariff device (meter) is normally the server, delivering the requested values or executing the requested tasks 3.1.4 slave station responding to requests of a master station. The t

43、ariff device (meter) is normally a slave station 3.2 Abbreviations COSEMCOmpanion Specification for Energy Metering DCEData Communication Equipment (communications interface or modem) DTEData Terminal Equipment (computers, terminals or printers) MSCMessage Sequence Chart PDUProtocol Data Unit PHPHys

44、ical layer PHPDUPHysical layer Protocol Data Unit PHSDUPHysical layer Service Data Unit SDUService Data Unit 5 egaP 2002:2465026 NE 2002 enuJ 61 Page 7 BSI 16 July 2002 Page 5 EN 6205642:2002 BSI 16 July 2002 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 12:44:48 GMT+00:00 2006, Uncontrolle

45、d Copy, (c) BSI 6 620-6542 ? CEI:0220(E) 4 Overview From the external point of view, the physical layer provides the interface between the DTE and the DCE, see Figure 2. Figure 1 shows a typical configuration for data exchange through a wide area network, for example the PSTN. kWh Schlumberger 00001

46、,6 10 (40)A 230V 50Hz (o) N 00012356 Transit network DTE to DCE ITU-T V series EIA RS232, RS485 Hayes, etc. DCE to DTE ITU-T V series EIA RS232, RS485 Hayes, etc Figure 1 Typical PSTN configuration From the physical connection point of view, all communications involve two sets of equipment represent

47、ed by the terms caller system and called system. The caller is the system that decides to initiate a communication with a remote system known as the called party; these denominations remain valid throughout the duration of the communication. A communication is broken down into a certain number of tr

48、ansactions. Each transaction is represented by a transmission from the transmitter to the receiver. During the sequence of transactions, the caller and called systems take turns to act as transmitter and receiver. From the data link point of view the central station normally acts as a master, taking

49、 the initiative and controlling the data flow. The tariff device is the slave, responding to the master station. From the application point of view the central station normally acts as a client asking for services, and the tariff device acts as a server delivering the requested services. The situation involving a caller client and a ca

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 其他


经营许可证编号:宁ICP备18001539号-1