BS-700-2-1982 ISO-835-2-1981.pdf

上传人:来看看 文档编号:3772786 上传时间:2019-09-23 格式:PDF 页数:14 大小:455.97KB
返回 下载 相关 举报
BS-700-2-1982 ISO-835-2-1981.pdf_第1页
第1页 / 共14页
BS-700-2-1982 ISO-835-2-1981.pdf_第2页
第2页 / 共14页
BS-700-2-1982 ISO-835-2-1981.pdf_第3页
第3页 / 共14页
BS-700-2-1982 ISO-835-2-1981.pdf_第4页
第4页 / 共14页
BS-700-2-1982 ISO-835-2-1981.pdf_第5页
第5页 / 共14页
亲,该文档总共14页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《BS-700-2-1982 ISO-835-2-1981.pdf》由会员分享,可在线阅读,更多相关《BS-700-2-1982 ISO-835-2-1981.pdf(14页珍藏版)》请在三一文库上搜索。

1、BRITISH STANDARD BS 700-2: 1982 ISO 835-2: 1981 Graduated pipettes Part 2: Specification for pipettes for which no waiting time is specified ISO title: Laboratory glassware Graduated pipettes Part 2: Pipettes for which no waiting time is required UDC 542.3:531.732:666.172.7 Licensed Copy: London Sou

2、th Bank University, London South Bank University, Fri Dec 08 13:29:48 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 700-2:1982 This British Standard, having been prepared under the direction of the Laboratory Apparatus Standards Committee, was published under the authority of the Board of BSI and co

3、mes into effect on 31 May 1982 BSI 03-1999 First published May 1937 First revision August 1952 Second revision June 1962 Third revision November 1976 Fourth revision, in Parts, May 1982 The following BSI references relate to the work on this standard: Committee reference LBC/27 Draft for comment 79/

4、54288 DC ISBN 0 580 12743 5 Cooperating organizations The Laboratory Apparatus Standards Committee, under whose direction this British Standard was prepared, consists of representatives from the following: Agricultural Research Council Association for Science Education British Educational Equipment

5、Association British Laboratory Ware Association* British Lampblown Scientific Glassware Manufacturers Association Ltd.* British Pharmacopoeia Commission Chemical Industries Association Department of Health and Social Security* Department of Industry (Laboratory of the Government Chemist)* Institute

6、of Petroleum Ministry of Defence* Pharmaceutical Society of Great Britain Royal Society of Chemistry Scientific Instrument Manufacturers Association Society of Chemical Industry* Society of Glass Technology Standardization of Tar Products Tests Committee The organizations marked with an asterisk in

7、the above list, together with the following, were directly represented on the Technical Committee entrusted with the preparation of this British Standard: Association of Clinical Biochemists Glass Manufacturers Federation Institute of Medical Laboratory Sciences Coopted member Amendments issued sinc

8、e publication Amd. No.Date of issueComments Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 13:29:48 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 700-2:1982 BSI 03-1999i Contents Page Cooperating organizationsInside front cover National forewordii 1Scope and fi

9、eld of application1 2References1 3Requirements for graduated pipettes1 Figure 1 Graduation and figuring of class A pipettes type 13 Figure 2 Graduation and figuring of class B pipettes type 13 Figure 3 Graduation and figuring of class A pipettes type 24 Figure 4 Graduation and figuring of class B pi

10、pettes type 24 Figure 5 Graduation and figuring of pipettes type 35 Table 1 Delivery times of type 1 pipettes1 Table 2 Lower end of scale of type 2 pipettes2 Table 3 Delivery times of type 2 pipettes2 Table 4 Lower end of scale of type 3 pipettes2 Table 5 Delivery times of type 3 pipettes2 Publicati

11、ons referred toInside back cover Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 13:29:48 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 700-2:1982 ii BSI 03-1999 National foreword This Part of this British Standard has been prepared under the direction of the La

12、boratory Apparatus Standards Committee. It is identical with ISO 835/2 “Laboratory glassware Graduated pipettes Part 2: Pipettes for which no waiting time is specified” published in 1981 by the International Organization for Standardization (ISO). BS 700 was originally published in 1937 and first re

13、vised in 1952 under the title “Graduated pipettes and one-mark cylindrical pipettes”. The standard was again revised in 1962, when the one-mark cylindrical pipettes were omitted from it, and account was taken of international standardization work in progress at that time. In 1968 ISO/R 835 was publi

14、shed which covered graduated pipettes types I and II, and BS 700 was revised in 1976 to take into account this ISO Recommendation and amendments to it that were under consideration. The earlier edition of BS 700 included requirements for a type III pipette which was adjusted for content from the jet

15、 to any graduation line. This was omitted from the 1976 revision because of lack of demand and was replaced by another pipette, also designated type III, but adjusted for delivery from the zero line (at the top) to the jet. In addition, the 1976 revision included requirements for a blowout pipette,

16、adjusted for delivery from the highest graduation line (at the top) to the jet, but with the last drop expelled by blowing. The method of use of this pipette is the responsibility of the user and for this reason alternative scales were permitted; one with the zero at the jet and the other with the z

17、ero at the highest graduation line, which reflects the general method of using the pipette as a dispenser. Pipettes of types III and IV were of class B accuracy only, and delivery times for types I and II pipettes were reduced. Proposals made by the UK for further revision of ISO/R 835 to include sh

18、orter delivery times for types I and II pipettes were accepted, and in 1981 the ISO Recommendation was revised and published in four Parts, ISO 835/1 to 835/4. The equivalent British Standards for ISO 835/1 and ISO 835/4 are BS 700-1 and BS 700-3 respectively. The Technical Committee responsible for

19、 this British Standard, whilst approving ISO 835/3 as an international standard, decided that there should be no British Standard corresponding to ISO 835/3 because graduated pipettes having a 15 s waiting time are not used in the UK and its markets. The principal differences between the 1976 editio

20、n and this edition include the introduction of a 0.5/0.01 ml pipette and a 25/0.01 ml pipette, both of class A accuracy. The blow-out pipettes are no longer designated as type IV and the alternative scale arrangement, with the zero at the top, for these pipettes has been deleted. The maximum scale l

21、engths of the types 2, 3 and blow-out pipettes have been increased by 10 %, and the ranges of the delivery times for class B types 1, 2 and 3 have been widened. This Part of this standard, together with Parts 1 and 3, supersedes BS 700:1976 which is withdrawn. Terminology and conventions. The text o

22、f the international standard has been approved as suitable for publication as a British Standard without deviation. Some terminology and certain conventions are not identical with those used in British Standards; attention is drawn especially to the following. The comma has been used throughout as a

23、 decimal marker. In British Standards it is current practice to use a full point on the baseline as the decimal marker. Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 13:29:48 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 700-2:1982 BSI 03-1999iii Wherever the

24、words “International Standard” appear, referring to this standard, they should be read as “British Standard”. The reference to ISO 835/3, which appears in clause 1 is for information only, and the lack of a corresponding British Standard does not affect the validity of this standard. A British Stand

25、ard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Cross-references International standardCorresponding Bri

26、tish Standard ISO 384-1978BS 5898:1980 Specification for principles of design and construction of volumetric glassware for laboratory use (Identical) BS 700 Graduated pipettes ISO 835/1-1981Part 1:1982 Specification for general requirements (Identical) ISO 835/4-1981Part 3:1982 Specification for blo

27、w-out pipettes (Identical) Summary of pages This document comprises a front cover, an inside front cover, pages i to iv, pages 1 to 6, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the am

28、endment table on the inside front cover. Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 13:29:48 GMT+00:00 2006, Uncontrolled Copy, (c) BSI iv blank Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 13:29:48 GMT+00:00 2006, U

29、ncontrolled Copy, (c) BSI BS 700-2:1982 BSI 03-19991 1 Scope and field of application This part of ISO 835 specifies requirements for three internationally acceptable series of graduated pipettes, for which no waiting time is specified, and which are adequate for general laboratory purposes. They ar

30、e adjusted to class A or class B accuracy. The requirements specified are in conformity with ISO 384 and ISO 835/1. NOTEParticular requirements for graduated pipettes with which a waiting time of 15 s is to be observed, are specified in ISO 835/3, and for blow-out pipettes in ISO 835/4. 2 References

31、 ISO 384, Laboratory glassware Principles of design and construction of volumetric glassware. ISO 835/1, Laboratory glassware Graduated pipettes Part 1: General requirements. 3 Requirements for graduated pipettes Unless otherwise stated in this International Standard graduated pipettes shall conform

32、 to the general requirements specified in ISO 835/1. 3.1 Requirements for type 1 pipettes 3.1.1 Definition of capacity The capacity corresponding to any graduation line of type 1 pipette is defined as the volume of water at 20 C, expressed in millilitres, delivered by the pipette at 20 C when emptie

33、d from the zero line to that graduation line, the outflow being unrestricted until making the final setting of the meniscus on the graduation line, and no period allowed for drainage of liquid adhering to the wall before making the final setting. NOTEWhere, exceptionally, the standard reference temp

34、erature is 27 C, this value shall be substituted for 20 C. The clean pipette shall be held in a vertical position and filled with distilled water to a few millimetres above the zero line; the falling meniscus shall then be set to the line. Any drop adhering to the jet of the pipette shall be removed

35、 by bringing the surface of a glass vessel into contact with the tip of the jet. Delivery shall then be made into another glass vessel slightly inclined so that the tip of the jet is in contact with the inside of the vessel, but without movement of one against the other throughout the delivery perio

36、d. 3.1.2 Graduation and figuring 3.1.2.1 For class A pipettes, graduation pattern 1 (see ISO 835/1) shall be applied; for figuring of graduation lines, see Figure 1. 3.1.2.2 For class B pipettes, graduation pattern 3 (see ISO 835/1) shall be applied; for figuring of graduation lines, see Figure 2. 3

37、.1.3 Delivery times Table 1 Delivery times of type 1 pipettes When the delivery time is marked on a pipette, then the observed delivery time and the marked delivery time shall both be within the limits given in Table 1 and shall not differ by more than 2 s. 3.2 Requirements for type 2 pipettes 3.2.1

38、 Definition of capacity The capacity corresponding to any graduation line of a type 2 pipette is defined as the volume of water at 20 C, expressed in millilitres, delivered by the pipette at 20 C when emptied from that graduation line to the jet, outflow being unrestricted until it is sure that the

39、meniscus has come to rest in the jet before removing the pipette from the receiving vessel. NOTEWhere, exceptionally, the reference temperature is 27 C, this value shall be substituted for 20 C. The clean pipette shall be held in a vertical position and filled with distilled water to a few millimetr

40、es above the graduation line; the falling meniscus shall then be set to the line. Any drop adhering to the jet of the pipette shall be removed by bringing the surface of a glass vessel into contact with the tip of the jet. Delivery shall then be made into another glass vessel slightly inclined so th

41、at the tip of the jet is in contact with the inside of the vessel, but without movement of one against the other throughout the delivery period. To ensure that delivery is complete, a waiting time of approximately 3 s should be observed before removing the pipette from the receiving vessel. NOTEThe

42、waiting period of 3 s is specified only for the purpose of definition. In use, it is unnecessary to adhere closely to this period; it is sufficient to be certain that the meniscus has come to rest in the jet before removing the pipette from contact with the receiving vessel. 3.2.2 Graduation and fig

43、uring 3.2.2.1 For class A pipettes, graduation pattern 1 (see ISO 835/1) shall be applied: for figuring of graduation lines, see Figure 3. Nominal capacity Delivery time Class AClass B min.max.min.max. mlssss 1710210 2812212 51014514 101317517 251521921 Licensed Copy: London South Bank University, L

44、ondon South Bank University, Fri Dec 08 13:29:48 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 700-2:1982 2 BSI 03-1999 3.2.2.2 For class B pipettes, graduation pattern 2 (see ISO 835/1) shall be applied; for figuring of graduation lines, see Figure 4. 3.2.2.3 Lowest and lowest figured graduation li

45、nes shall be in accordance with Table 2. Table 2 Lower end of scale of type 2 pipettes NOTEThese figures are calculated taking into account the requirement that 10 mm of uniform bore shall lie below lowest graduation line. 3.2.3 Delivery times Table 3 Delivery times of type 2 pipettes When the deliv

46、ery time is marked on a pipette, then the observed delivery time and the marked delivery time shall both be within the limits given in Table 3 and shall not differ by more than 2 s. 3.3 Requirements for type 3 pipettes 3.3.1 Definition of capacity The capacity corresponding to any graduation line of

47、 a type 3 pipette is defined as the volume of water at 20 C, expressed in millilitres, delivered by the pipette at 20 C when emptied from the zero line to that graduation line or, in the case of total capacity delivering, to the jet the outflow being unrestricted until making the final setting of th

48、e meniscus on the graduation line, and no period allowed for draining of liquid adhering to the wall before making the final setting. NOTEWhere, exceptionally, the standard reference temperature is 27 C, this value shall be substituted for 20 C. The clean pipette shall be held in a vertical position

49、 and filled with distilled water to a few millimetres above the zero line; the falling meniscus shall then be set to the line. Any drop adhering to the jet of the pipette shall be removed by bringing the surface of a glass vessel into contact with the tip of the jet. Delivery shall then be made into another glass vessel slightly inclined so that the tip of the jet is in contact with the inside of the vessel, but without movement of one against the other throughout the delivery period. To ensure that delivery in the

展开阅读全文